X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-031-23598

Well Details

Well ID: 37-031-23598
Loading map...
Country: United States
State: Pennsylvania
County: Clarion
Municipality: Redbank Township
Operator Name: SNYDER BROS INC
Well Pad ID:
Farm/Lease Name: DELORES E SHERMAN 5 81
License Status: ACTIVE
Spud Date:
Permit Date: 2002-05-06
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 41.052220
Longitude: -79.247560

For data sources see[1][2][3]

Well History

Date Event
2002-05-06 New Permit Application
2002-06-24 Performed Spud Operation
2002-06-26 Drilling Completion
2002-07-12 Perforation
2002-10-29 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2002 SNYDER BROS INC 2476 58 0.00 0 0.00 0
2003 SNYDER BROS INC 13315 365 0.00 0 0.00 0
2004 SNYDER BROS INC 4644 292 0.00 0 0.00 0
2005 SNYDER BROS INC 2989 280 0.00 0 0.00 0
2006 SNYDER BROS INC 2649.00 332 0.00 0 0.00 0
2007 SNYDER BROS INC 8188.00 365 0.00 0 0.00 0
2008 SNYDER BROS INC 14950.00 374 0.00 0 0.00 0
2009 SNYDER BROS INC 13762.00 377 0.00 0 0.00 0
2010 SNYDER BROS INC 8,379.00 365 0.00 0 0.00 0
2011 SNYDER BROS INC 6,475.00 330 0.00 0 0.00 0
2012 SNYDER BROS INC 6,286.00 356 0.00 0 0.00 0
2013 SNYDER BROS INC 5,510.00 361 0.00 0 0.00 0
2014 SNYDER BROS INC 5,237.00 365 0.00 0 0.00 0
2015 SNYDER BROS INC 4,527.00 365 0.00 0 0.00 0
2016 SNYDER BROS INC 3,718.00 363 0.00 0 0.00 0
2017 SNYDER BROS INC 3,915.00 365 0.00 0 0.00 0
2018 SNYDER BROS INC 2,928.00 365 0.00 0 0.00 0
2019 SNYDER BROS INC 2,953.00 356 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2006 SNYDER BROS INC Brine 60.00 Bbl Reuse other than road spreading
2008 SNYDER BROS INC Brine 171.00 Bbl Reuse other than road spreading
2008 SNYDER BROS INC Brine 84.00 Bbl Road Spreading
2009 SNYDER BROS INC Brine 40.00 Bbl Reuse other than road spreading
2009 SNYDER BROS INC Brine 51.00 Bbl Road Spreading
2010 SNYDER BROS INC Produced Fluid 30.00 Bbl Reuse other than road spreading
2010 SNYDER BROS INC Produced Fluid 70.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011 SNYDER BROS INC Produced Fluid 15.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0095443
2012 SNYDER BROS INC Produced Fluid 70.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2013 SNYDER BROS INC Produced Fluid 35.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0101508
2013 SNYDER BROS INC Produced Fluid 35 Bbl CENT WASTE TRT FAC NPDES PA0101508
2014 SNYDER BROS INC Produced Fluid 35.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0101508
2014 SNYDER BROS INC Produced Fluid 35 Bbl CENT WASTE TRT FAC NPDES PA0101508
2016 SNYDER BROS INC Produced Fluid 90.00 Bbl Reuse other than road spreading
2017 SNYDER BROS INC Produced Fluid 78.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2019 SNYDER BROS INC Produced Fluid 106.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1144478 Primary Facility 2002-06-25 Drilling/Alteration No Violations Noted
2046656 Primary Facility 2012-02-22 Routine/Complete Inspection No Violations Noted
2539690 Primary Facility 2016-10-25 Routine/Partial Inspection No Violations Noted
2771119 Primary Facility 2018-08-31 Routine/Partial Inspection No Violations Noted At the time of inspection, well was equipped for production. Well integrity appeared to be in good condition, with no signs of any leaks at the site. Well was rusty, but no major corrosion was noticed. There was a pump jack (which ran on gasoline) and drip hooked up to the well. There was a chart, which had been changed this morning, onsite. There was also a 100 bbl tank being used. The well was properly labeled. Label was attached to the horse-head of the pump jack. Production was reported in 2017 as 3915 mcf for 365 days.

For data sources see[7]

References