X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-027-21618

Well Details

Well ID: 37-027-21618
Loading map...
Country: United States
State: Pennsylvania
County: Centre
Municipality: Burnside Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 148768
Farm/Lease Name: LITKE UNIT P-4 32H
License Status:
Spud Date:
Permit Date: 2010-04-30
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.092411
Longitude: -77.955308

For data sources see[1][2][3]

Well History

Date Event
2010-04-30 New Permit Application
2010-05-31 Performed Spud Operation
2010-08-22 Drilling Completion
2010-10-23 Perforation
2012-07-23 DEVIATED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 EXCO RESOURCES PA INC 0.00 0 0.00 0 0.00 0
2011 EXCO RESOURCES PA INC 144,883.00 303 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 111,576.00 366 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 95,218.00 365 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 90,033.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 87,655.00 362 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 90,250.00 364 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 75,396.00 276 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 88,874.00 341 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 15,587.00 138 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 EXCO RESOURCES PA INC Produced Fluid 717.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAS2D205BCLE
2010 EXCO RESOURCES PA INC Produced Fluid 348.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 EXCO RESOURCES PA INC Fracing Fluid Waste 22,235.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 EXCO RESOURCES PA INC Produced Fluid 228.76 Bbl STORAGE PENDING DISPOSAL OR REUSE
2011 EXCO RESOURCES PA INC Drilling Fluid Waste 1,333.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 EXCO RESOURCES PA INC Drilling Fluid Waste 200.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAS2D205BCLE
2011 EXCO RESOURCES PA INC Produced Fluid 202.07 Bbl INJECTION DISPOSAL WELL 34-059-24067
2011 EXCO RESOURCES PA INC Produced Fluid 1,381.40 Bbl INJECTION DISPOSAL WELL 34-119-27350
2011 EXCO RESOURCES PA INC Produced Fluid 267.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 EXCO RESOURCES PA INC Produced Fluid 113.56 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2011 EXCO RESOURCES PA INC Produced Fluid 110.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 EXCO RESOURCES PA INC Produced Fluid 2,854.40 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PAS2D205BCLE
2012 EXCO RESOURCES PA LLC Produced Fluid 1,435.15 Bbl INJECTION DISPOSAL WELL 34-119-27350
2012 EXCO RESOURCES PA LLC Produced Fluid 1,382.26 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2012 EXCO RESOURCES PA LLC Produced Fluid 202.07 Bbl STORAGE PENDING DISPOSAL OR REUSE
2013 EXCO RESOURCES PA LLC Produced Fluid 2,716.74 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2014 EXCO RESOURCES PA LLC Produced Fluid 2,802.88 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2015 EXCO RESOURCES PA LLC Produced Fluid 3,023.10 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid 105.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 EXCO RESOURCES PA LLC Produced Fluid 3,502.80 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 2,924.20 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2018 EXCO RESOURCES PA LLC Produced Fluid 314.00 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018 EXCO RESOURCES PA LLC Produced Fluid 2,701.70 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 916.90 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1894250 Primary Facility 2010-06-23 Drilling/Alteration No Violations Noted Top hole drilling complete.
1907623 Primary Facility 2010-08-17 Drilling/Alteration No Violations Noted Patterson Drilling Rig #257 is currently drilling a 8 3/4" hole through the curve at 8270'.
1917314 Primary Facility 2010-09-08 Routine/Complete Inspection No Violations Noted
1941979 Primary Facility 2010-11-08 Routine/Complete Inspection De minimus Violations Noted
1953839 Primary Facility 2011-01-25 Routine/Complete Inspection No Violations Noted
1968745 Primary Facility 2011-03-10 Routine/Complete Inspection No Violations Noted
1986389 Primary Facility 2011-05-24 Compliance Evaluation Outstanding Violations - No Viols Req'd
1998552 Primary Facility 2011-07-19 Compliance Evaluation Outstanding Violations - No Viols Req'd
1998605 Primary Facility 2011-08-17 Compliance Evaluation Outstanding Violations - No Viols Req'd
1998663 Primary Facility 2011-08-23 Compliance Evaluation Outstanding Violations - No Viols Req'd
1998694 Primary Facility 2011-08-24 Compliance Evaluation No Violations Noted
1998719 Primary Facility 2011-08-25 Compliance Evaluation Outstanding Violations - No Viols Req'd
2016784 Primary Facility 2011-08-29 Routine/Complete Inspection No Violations Noted
2019223 Primary Facility 2011-09-06 Routine/Complete Inspection No Violations Noted
2022959 Primary Facility 2011-09-23 Routine/Complete Inspection No Violations Noted
2023007 Primary Facility 2011-09-26 Routine/Complete Inspection No Violations Noted
2024337 Primary Facility 2011-10-04 Routine/Complete Inspection No Violations Noted
2065828 Primary Facility 2012-03-28 Routine/Complete Inspection No Violations Noted
2085877 Primary Facility 2012-05-25 Routine/Complete Inspection No Violations Noted
2117145 Primary Facility 2012-11-15 Routine/Complete Inspection No Violations Noted
2188333 Primary Facility 2013-07-26 Routine/Complete Inspection No Violations Noted
2487358 Primary Facility 2016-05-23 Routine/Complete Inspection No Violations Noted
2705350 Primary Facility 2018-02-21 Routine/Complete Inspection No Violations Noted The weather is 70 Deg. F, cloudy and windy at time of inspection. Routine inspection of EXCO Resources PA LLC., Litke Pad, Well # 32H on February 21, 2018. There are 4 producing wells on this pad.

Annular vent is open and vented at the time of inspection. Digital pressure gauge on the top of the production xmas tree reads 732 PSI, casing pressure gauge reads 733 psi. 100% LEL and 100% combustible gas was detected at the 5-1/2" x 2-3/8" annulus vent. No obvious concerns or violations are noted at time of inspection. Wellsite looks neat and well organized. EXCO Resources, LLC. Representative ¿ Sam Unch, Production Operator. DEP Representative - Ulyana Trynovich, Oil and Gas Inspector.

2705858 Primary Facility 2018-03-09 Routine/Complete Inspection No Violations Noted Routine site inspection at EXCO Resources LLC Litke 4 Pad on March 9, 2018.

The site sign, drilling permits, weekly E&S log, PPC plan, emergency response plan (ERP), and work description of the pad and impoundments were found onsite. Please note that the PPC plan and ERP are dated June 2013 and February 2014 respectively. The Department recommends that the operator update both plans and place a copy onsite.

There are 4 drilled and producing Marcellus wells located on the pad. All well cellars are full of gravel and each well is properly labeled. There are two series of produced fluids tanks stationed in secondary containment on this pad (photo 5). Water within containment was frozen. No signs of leaks from the containment were observed. Each tank was labeled.

Part of the well pad has been partially restored. In addition, both impoundments have been fully restored. No E&S issues were observed.

2741722 Primary Facility 2018-06-13 Routine/Complete Inspection No Violations Noted Routine site inspection at EXCO Resources LLC Litke 4 Pad on June 13, 2018.

The site sign, drilling permits, weekly E&S log, PPC plan, emergency response plan (ERP), and work description of the pad and impoundments were found onsite. Please note that the PPC plan and ERP are dated June 2013 and February 2014 respectively. The Department recommends that the operator update both plans and place a copy onsite.

There are 4 drilled and producing Marcellus wells located on the pad. All well cellars are full of gravel. There are (2) 400 bbl produced fluids tanks stationed in secondary containment on this pad. Conductivity readings in this containment were 298 uS/cm. In addition, there are (3) 200 bbl produced fluids tanks stationed in secondary containment. Conductivity in this containment was 427 uS/cm. No signs of leaks from either containment were observed. Each tank was properly labeled.

Part of the well pad has been partially restored. In addition, both impoundments have been fully restored. No E&S issues

2852692 Primary Facility 2019-03-12 Routine/Complete Inspection No Violations Noted Department representative Sue Herzing conducted a routine site inspection at EXCO Resources PA LLC Litke Pad 4 on March 12, 2019.

There are 4 drilled and producing Marcellus wells located on the pad. All well cellars are full of gravel and/or snow. There are (2) 400 bbl produced fluids tanks stationed in secondary containment. In addition, there are (3) 200 bbl produced fluids tanks stationed in a separate secondary containment. Frozen water was observed in both sets of produced fluids secondary containment. No signs of leaks from either containment were observed. Each produced fluids tank was labeled.

Part of the well pad has been partially restored. In addition, both impoundments (2 & 3 MG) have been fully restored and are well vegetated. No E&S issues were observed. The well pad and surrounding areas are partially snow covered.

No violations noted.

For data sources see[7]

References