Well ID: 37-027-20468 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.121984,"lon":-77.95124,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Centre | |
Municipality: Burnside Township | |
Operator Name: ALLIANCE PETRO CO LLC | |
Well Pad ID: | |
Farm/Lease Name: COMMONWEALTH OF PENNSYLVANIA-TR 706 5 | |
License Status: ACTIVE | |
Spud Date: 1990-08-22 | |
Permit Date: 1990-08-14 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 41.121984 | |
Longitude: -77.951240 |
Date | Event |
---|---|
1990-08-14 | New Permit Application |
1990-08-22 | Performed Spud Operation |
1990-08-29 | Drilling Completion |
1990-09-04 | Perforation |
1990-09-04 | Performed Stimulation |
1991-01-01 | Newly Drilled |
2018-06-29 | Begin Plugging |
2018-07-03 | Finished Plugging |
2019-07-18 | Fully Plugged |
For data sources see[4]
Stimulation Date | Phase Number | Chemical Agent | Volume (gal) | Treating Pressure (psi) | Breakdown Pressure (psi) |
---|---|---|---|---|---|
1990-09-04 | Sand | 0 | 0 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
1991 | EQUITABLE PROD EASTERN STATES EXPLORATION INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
1997 | EQUITABLE PROD EASTERN STATES EXPLORATION INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
1999 | EQUITABLE PROD EASTERN STATES EXPLORATION INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2000 | EQUITRANS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2001 | EQUITABLE PROD EASTERN STATES EXPLORATION INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2004 | EXCO RESOURCES PA INC | 206 | 365 | 0.00 | 0 | 0.00 | 0 |
2005 | EXCO RESOURCES PA INC | 729.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2006 | EXCO RESOURCES PA INC | 771.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2007 | EXCO RESOURCES PA INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2008 | EXCO RESOURCES PA INC | 401.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2009 | EXCO RESOURCES PA INC | 293.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2010 | EXCO RESOURCES PA INC | 275.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2011 | EXCO RESOURCES PA INC | 209.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2012 | EXCO RESOURCES PA LLC | 256.00 | 366 | 0.00 | 0 | 0.00 | 0 |
2013 | EXCO RESOURCES PA LLC | 199.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2014 | EXCO RESOURCES PA LLC | 113.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2015 | EXCO RESOURCES PA LLC | 121.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2016 | ALLIANCE PETRO CO LLC | 92.00 | 183 | 0.00 | 0 | 0.00 | 0 |
2017 | ALLIANCE PETRO CO LLC | 258.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2018 | ALLIANCE PETRO CO LLC | 157.00 | 365 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1052292 | Primary Facility | 2001-07-31 | Routine/Complete Inspection | No Violations Noted | well is not hooked up or operating,E&S ok inactive. |
213979 | Primary Facility | 1991-09-26 | Site Restoration | No Violations Noted | SITE RESTORED; INACTIVE |
217809 | Primary Facility | 1996-05-16 | Routine/Complete Inspection | No Violations Noted | INACTIVE; E&S OK |
2738235 | Primary Facility | 2018-06-05 | Routine/Complete Inspection | No Violations Noted | Department representative Sue Herzing conducted a routine site inspection with Steve Melman of DCNR, and Larry Fetterman and Drew Adamo of Diversified Gas & Oil Corporation (DGOC) on June 5, 2018.
DGOC is planning to plug conventional well 027-20468 (COP 706-5) starting in June-July 2018. This well is located on Sproul State Forest. This well is owned/operated by Alliance Petroleum Corporation which is a subsidiary of DGOC. The "notice of intention by well operator to plug a well" has already been submitted and received by the Department. As discussed during the field meeting, the plugging rig will be placed on containment. In addition, any tanks or fueling tanks shall be placed on secondary containment. A well control and disposal plan was provided during the meeting and it will be stationed onsite during the plugging operation. Once plugging is completed the operator will seed and mulch any disturbed areas with DCNR's seed mixture. The access road leading to the conventional well will be scarified and |
2748210 | Primary Facility | 2018-07-03 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Howard Drilling are rigged up on location for plug and abandonment. I met with the driller to discuss operations. They tagged bottom at 4670', pumped bottom plug, pulled 29' jts. They'll shoot off 4 1/2" casing at 2406' , above where CBL reportedly indicated TOC. They are pulling their workstring out of the hole and waiting on shooter. No obvious issues were observed or reported. |
2753262 | Primary Facility | 2018-07-18 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | Howard Drilling are off location following the final plug and abandonment of this conventional well. At the time of inspection; the plugged well is covered witn gravel and a 2" non-venting monument with marker has been erected on the plugged well. There were no open holes, venting, discharges, or obvious issues observed. No gas was detected with an Altair 5x monument at the base of the monument. |
For data sources see[7]