Well Details

Well ID: 37-023-20181
Loading map...
Country: United States
State: Pennsylvania
County: Cameron
Municipality: Shippen Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 151772
Farm/Lease Name: SRC WT 5034
License Status: Active
Spud Date: 2015-03-12
Permit Date: 2014-10-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.570880
Longitude: -78.351646

For data sources see[1][2][3]

Well History

Date Event
2014-10-10 New Permit Application
2014-12-19 New Permit Application
2015-03-11 Performed Spud Operation
2015-06-27 Drilling Completion
2017-08-30 Perforation
2017-08-30 Performed Stage 1 of Stimulation
2017-08-31 Perforation
2017-08-31 Performed Stage 2 of Stimulation
2017-09-01 Perforation
2017-09-01 Performed Stage 3 of Stimulation
2017-09-06 Perforation
2017-09-06 Performed Stage 4 of Stimulation
2017-09-06 Performed Stage 5 of Stimulation
2017-09-06 Performed Stage 6 of Stimulation
2017-09-09 Perforation
2017-09-09 Performed Stage 7 of Stimulation
2017-09-09 Performed Stage 8 of Stimulation
2017-09-09 Performed Stage 9 of Stimulation
2017-09-10 Performed Stage 10 of Stimulation
2017-09-13 Perforation
2017-09-13 Performed Stage 11 of Stimulation
2017-09-13 Performed Stage 12 of Stimulation
2017-09-14 Perforation
2017-09-14 Performed Stage 13 of Stimulation
2017-09-14 Performed Stage 14 of Stimulation
2017-09-14 Performed Stage 15 of Stimulation
2017-09-15 Perforation
2017-09-15 Performed Stage 16 of Stimulation
2017-09-15 Performed Stage 17 of Stimulation
2017-09-18 Perforation
2017-09-18 Performed Stage 18 of Stimulation
2017-09-19 Perforation
2017-09-19 Performed Stage 19 of Stimulation
2017-09-19 Performed Stage 20 of Stimulation
2017-09-20 Perforation
2017-09-20 Performed Stage 21 of Stimulation
2017-09-20 Performed Stage 22 of Stimulation
2017-09-21 Perforation
2017-09-21 Performed Stage 23 of Stimulation
2017-09-21 Performed Stage 24 of Stimulation
2017-09-21 Performed Stage 25 of Stimulation
2017-09-24 Perforation
2017-09-24 Performed Stage 26 of Stimulation
2017-09-24 Performed Stage 27 of Stimulation
2017-09-25 Perforation
2017-09-25 Performed Stage 28 of Stimulation
2017-09-25 Performed Stage 29 of Stimulation
2017-09-26 Perforation
2017-09-26 Performed Stage 30 of Stimulation
2017-09-26 Performed Stage 31 of Stimulation
2017-09-27 Perforation
2017-09-27 Performed Stage 32 of Stimulation
2017-09-27 Performed Stage 33 of Stimulation
2017-09-28 Performed Stage 34 of Stimulation
2017-09-28 Performed Stage 35 of Stimulation
2017-09-29 Performed Stage 36 of Stimulation
2017-09-29 Performed Stage 37 of Stimulation
2017-09-29 Performed Stage 38 of Stimulation
2017-09-30 Performed Stage 39 of Stimulation
2017-09-30 Performed Stage 40 of Stimulation
2020-02-25 Deviated

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-08-30 2017-09-30 5,404 9,483,010 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 KSI-19 NW Keane Scale Inhibitor Aqueous Solution Proprietary 100 0.0103288 9295
KAI-12 Keane Acid Inhibitor alcohols, c7-9-0so, c8-rich 68526-83-0 5 0.00005825 52.423
prop-2-yn-1-0l 107-19-7 5 0.00005825 52.423
ethylbenzene 100-41-4 1 0.00001165 10.485
xylne 1330-20-7 5 0.00005825 52.423
fatty imidazoline 61790-69-0 5 0.00005825 52.423
propan-2-ol 67-63-0 5 0.00005825 52.423
methanol 67-56-1 90 0.00104856 943.612
7.5% Acid Keane Acidizing Hydrochloric Acid 7647-01-0 7.5 0.0335766 30216
Water 7732-18-5 92.5 0.414112 372664
Water (Clean - Acid - Chems) Seneca Resources Carrier/Base Fluid Water 7732-18-5 100 87.9373 79,135,700.0
MBC-516 Keane Biocide ethanol 64-17-5 2.8 0.000247548 222.771
quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 5.3 0.000469458 422.47
gluteral 111-30-8 26.7 0.00236055 2124.28
Didecyl dimethyl ammonium chloride 7173-51-5 8 0.000704628 634.103
KFEAC-30 Keane Iron Control Acetic acid 64-19-7 60 0.000442726 398.414
Citric acid 77-92-9 40 0.000295151 265.609
DustProof (Proppant) Keane Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 99.9 11.2945 10,164,100.0
Blend Proprietary 0.1 0.0113058 10174.3
Sand (Proppant) (lbs) Keane Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 100 0.195197 175660
KFR-20 Keane Friction Reducer cololymer of 2-propenamide 69418-26-4 30 0.0278757 25085.7
Ammonium Chloride 12125-02-9 1 0.000929191 836.189
Mineral oil/ light hydrotreated pet. distillate 64742-47-8 20 0.0185838 16723.8
Water 7732-18-5 45 0.0418136 37628.5
oleic acid diethanolamide 93-83-4 2 0.00185838 1672.38
Alcohols, C12-16, ethoxylated 68551-12-2 2 0.00185838 1672.38

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2017-08-30 1 Ottawa 280,824 7,246 6,883
2017-08-31 2 Ottawa 280,824 7,353 8,272
2017-09-01 3 Ottawa 280,824 7,551 4,971
2017-09-06 4 Ottawa 280,824 7,482 4,922
2017-09-06 5 Ottawa 280,824 7,456 4,736
2017-09-06 6 Ottawa 280,824 7,119 4,886
2017-09-09 7 Ottawa 280,824 7,530 4,573
2017-09-09 8 Ottawa 280,824 7,545 5,834
2017-09-09 9 Ottawa 280,824 7,477 5,867
2017-09-10 10 Ottawa 280,824 7,263 5,462
2017-09-13 11 Ottawa 280,824 7,452 5,524
2017-09-13 12 Ottawa 280,824 7,359 6,143
2017-09-14 13 Ottawa 280,824 7,296 6,020
2017-09-14 14 Ottawa 280,824 7,175 5,624
2017-09-14 15 Ottawa 280,824 7,369 6,131
2017-09-15 16 Ottawa 280,824 6,995 5,431
2017-09-15 17 Ottawa 280,824 6,751 5,031
2017-09-18 18 Ottawa 280,824 7,300 5,684
2017-09-19 19 Ottawa 280,824 6,204 5,112
2017-09-19 20 Ottawa 280,824 7,056 4,985
2017-09-20 21 Ottawa 280,824 7,261 5,179
2017-09-20 22 Ottawa 280,824 7,244 5,087
2017-09-21 23 Ottawa 280,824 7,347 5,436
2017-09-21 24 Ottawa 280,824 7,240 4,916
2017-09-21 25 Ottawa 280,824 7,193 4,503
2017-09-24 26 Ottawa 280,824 7,396 3,310
2017-09-24 27 Ottawa 280,824 7,179 5,503
2017-09-25 28 Ottawa 280,824 6,950 4,695
2017-09-25 29 Ottawa 280,824 6,664 6,664
2017-09-26 30 Ottawa 280,824 6,490 4,321
2017-09-26 31 Ottawa 280,824 6,316 6,316
2017-09-27 32 Ottawa 280,824 5,945 5,945
2017-09-27 33 Ottawa 280,824 6,071 6,071
2017-09-28 34 Ottawa 280,824 5,989 5,989
2017-09-28 35 Ottawa 280,824 5,733 5,733
2017-09-29 36 Ottawa 280,824 5,486 5,486
2017-09-29 37 Ottawa 280,824 5,876 5,876
2017-09-29 38 Ottawa 280,824 5,902 5,902
2017-09-30 39 Ottawa 280,824 5,686 5,686
2017-09-30 40 Ottawa 280,824 5,825 5,825

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2015 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 112,374.05 61 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 306,246.33 364 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 201,262.14 358 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2015 SENECA RESOURCES CO LLC Drill Cuttings 1,424.05 Tons LANDFILL 100361
2016 SENECA RESOURCES CO LLC Synthetic Liner Materials 3.21 Tons LANDFILL 100361
2016 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 96.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 25.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 SENECA RESOURCES CO LLC Servicing Fluid 96.25 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 166.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid 44,423.37 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 55.00 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Synthetic Liner Materials 0.73 Tons LANDFILL 100361
2017 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 318.53 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Unused Fracturing Fluid Waste 279.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 SENECA RESOURCES CO LLC Produced Fluid 79.00 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Produced Fluid 162.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 SENECA RESOURCES CO LLC Waste Water Treatment Sludge 31.20 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 SENECA RESOURCES CO LLC Produced Fluid 43,204.44 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Soil Contaminated by Oil & Gas Related Spills 8.24 Tons LANDFILL 100361
2018 SENECA RESOURCES CO LLC Produced Fluid 208.75 Bbl INJECTION DISPOSAL WELL PAS2D025BELK
2018 SENECA RESOURCES CO LLC Soil Contaminated by Oil 8.24 Tons LANDFILL 100361
2018 SENECA RESOURCES CO LLC Produced Fluid 131.25 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 1.25 Bbl INJECTION DISPOSAL WELL PAS2D025BELK
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 331.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Synthetic Liner Materials 0.50 Tons LANDFILL 100361
2018 SENECA RESOURCES CO LLC Produced Fluid 12.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Synthetic Liner Materials 0.26 Tons LANDFILL 100361
2019 SENECA RESOURCES CO LLC Produced Fluid 15,446.98 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 641.09 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Produced Fluid 491.08 Bbl INJECTION DISPOSAL WELL PAS2D025BELK
2019 SENECA RESOURCES CO LLC Produced Fluid 183.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 111.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Produced Fluid 225.25 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2351140 Primary Facility 2015-03-11 Routine/Complete Inspection No Violations Noted
2351815 Primary Facility 2015-03-12 Drilling/Alteration No Violations Noted At the time of inspection Sunny sky ~12” snow cover and ~27° F.
2353603 Primary Facility 2015-03-19 Routine/Complete Inspection No Violations Noted
2355711 Primary Facility 2015-03-25 Drilling/Alteration No Violations Noted At the time of inspection Cloudy sky, light rain and ~33° F.
2357084 Primary Facility 2015-04-01 Routine/Complete Inspection No Violations Noted
2358087 Primary Facility 2015-04-02 Routine/Complete Inspection No Violations Noted
2359981 Primary Facility 2015-04-07 Routine/Complete Inspection No Violations Noted At the time of inspection cloudy sky, light rain and ~45° F.
2365283 Primary Facility 2015-04-23 Routine/Complete Inspection No Violations Noted
2378076 Primary Facility 2015-06-05 Drilling/Alteration No Violations Noted At the time of inspection sunny sky, ~ 70° F.
2432264 Primary Facility 2015-12-08 Routine/Complete Inspection No Violations Noted
2470490 Primary Facility 2016-03-30 Routine/Complete Inspection No Violations Noted
2474103 Primary Facility 2016-04-12 Routine/Complete Inspection No Violations Noted
2506064 Primary Facility 2016-07-27 Routine/Complete Inspection No Violations Noted
2610256 Primary Facility 2017-06-13 Routine/Complete Inspection No Violations Noted
2616250 Primary Facility 2017-07-18 Administrative/File Review Violation(s) Noted Administrative Inspection Record created for the purpose of entering Enforcement Record for failure to plug an abandoned well.
2622134 Primary Facility 2017-07-26 Routine/Complete Inspection No Violations Noted Routine inspection of Seneca Resources Corp CRV PAD C09-G on July 26, 2017. No one was onsite during my inspection.

Rig mats remain onsite with a total of 25 produced fluids frac containers. It appears that the operator is gearing up for well stimulation. All wells are labeled with the well number and operator. A total of 9 wells have been TD. Well 023-20182 has been drilled and plugged.

There are 6 produced fluids silos located in secondary containment onsite. Field screen reading for specific conductance within this containment was 82.0 uS/cm.

Overall, the pad is in good condition and all necessary BMPs are in place surrounding the well pad.

The sign located at the entrance to the well pad only has a total of 7 well listed. This does not match with the number of drilled wells onsite. I recommend updating the well site to reflect the number of drilled wells onsite.

2627521 Primary Facility 2017-08-18 Routine/Complete Inspection No Violations Noted Routine inspection of Seneca Resources Corp CRV PAD C09-G on August 17, 2017 with company man Adam Pierce of Seneca Resources.

Crews were currently working on fracing Marcellus wells 023-20178, 023-20179, 023-20183, and 023-20184. The fracing crew was approximately half way done with fracing these four wells. Once finished they will move the rig over and work on stimulating Marcellus wells 023-20180, 023-20181, 023-20182, and 023-20198. According to Mr. Pierce, crews are installing a perforation string downhole and with 8 perforation holes per every 2 ft. section of the string. Plugs made of a composite are being placed between 190 ft. perforation stages.

Sand is being hauled via trucks from the Cameron County rail yard. Water used for stimulation is being transferred to this pad via the above ground water line from the Clermont Water Treatment Facility. The above ground waterline is plumbed into a series of manifolded frac tanks.

All equipment is placed on secondary containment. Overall, the pad is i

2630944 Primary Facility 2017-08-15 Routine/Complete Inspection No Violations Noted
2643028 Primary Facility 2017-09-28 Routine/Complete Inspection No Violations Noted Routine inspection of Seneca Resources Corp CRV PAD C09-G on September 28, 2017 with company man Scott Digel of Seneca Resources.

Crews were currently working on fracing Marcellus wells 023-20182, 023-20183, and 023-20184. The fracing crew was almost completed with well stimulation on these 3 wells. Stimulation been completed on wells 023-20178, 023-20179, 023-29180, 023-20181, and 023-20198. According to Mr. Digel, once all of the wells have been stimulated, crews will remove this rig and bring in 2 work-over rigs to drill out the plugs on the above mentioned wells.

Sand is being hauled via trucks from the Cameron County rail yard, then being trucked to this site. Water used for well stimulation is being transferred to this pad via the above ground water line from the Clermont Water Treatment Facility. The above ground waterline is plumbed into a series of manifolded frac tanks. These tanks are located along the Eastern border of the pad.

All equipment is placed on secondary containment. Overall, th

2668167 Primary Facility 2017-12-06 Routine/Complete Inspection No Violations Noted This well was in production at the time of this inspection. The tubing pressure (production) was 927 psi. at this inspection. All fittings on the wellhead assembly and vented annulus 20x13, 13x9 and 9x5 were checked at this inspection. The pad and well area were neat and organized at this inspection.
2672474 Primary Facility 2017-12-15 Routine/Complete Inspection No Violations Noted Routine inspection of Seneca Resources CRV PAD C09-G on December 15, 2017.

There are a total of 8 producing Marcellus wells located on this pad. Rig mats from the recent flowback operation have been removed and are currently being stationed along the N edge of the well pad. There is one frac tank stationed on man-made secondary containment with a berm near the well heads. There are 4 frac tanks located near the produced fluids containment along the S border. These frac tanks are currently not located in secondary containment nor to they appear to be connected to anything. There are (6) 400 BBL produced fluids tanks located in modular secondary containment. Water within the containment is frozen and snow covered. In addition, there's a row of 22 frac tanks stationed along the E edge of the well pad. This series of 22 frac tanks are stationed in secondary man made containment with a berm. There are 8 gas production units stationed along the W edge of the well pad.

The pad and surrounding areas are snow cove

2707920 Primary Facility 2018-03-20 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The wellhead assembly, annulus vents 20" x 13 3/8", 13 3/8" x 9 5/8" and 9 5/8" x 5 1/2" were tested for gas. Results of this testing was that 17% LEL(lower explosion limit) and 0% Methane was detected on the 9 5/8" x 5 1/2" annulus vent. No other gas was detected on the wellhead assembly or the well area.
2734714 Primary Facility 2018-05-24 Incident- Response to Accident or Event No Violations Noted I arrived onsite and met with Jeff Passarello of Seneca in response to a spill report. Between 3 and 4 AM on 5/24, a worker on the site set up to pump produced water from both the Baker tank battery and the production tanks to the Clermont storage facility. The same pump is used to pump water from the well cellars (when needed) along with the produced water, but no pumping was occurring at the cellars. A water line is left in place to the cellars, but capped ~20' from the cellars to allow vehicle traffic through. When the worker turned on the pump, the cap popped off of the water line to the cellars and spilled ~1 1/2 barrels of produced water from the pump to the pad surface. When I arrived, approximately a third to a half of the spill area had already been excavated and a 30 yard dumpster filled. Jeff informed me that they were waiting on another rolloff to continue the excavation. The gravel was underlain by a clay layer, making visual confirmation of the spill removal possible, but Jeff was also u
2792974 Primary Facility 2018-10-16 Routine/Complete Inspection No Violations Noted Department representative Sue Herzing conducted a routine site inspection at Seneca Resources CRV C09-G Well Pad on October 16, 2018. There are a total of 8 drilled and producing wells located on this well pad. All well heads are properly tagged. Well cellars are full of water. No bubbling or sheen observed in the cellars. There are (6) 400 bbl. produced fluids tanks stationed in secondary containment. Approximately 1" of rain water was found in the produced fluids secondary containment with a conductivity reading of 78.8 uS/cm. A series of 12 manifolded frac tanks are being stationed on secondary along the NE edge of the well pad. Just a trace of water was observed within this containment. Overall, the well site looks good. No violations noted.
2807487 Primary Facility 2018-11-28 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. There are two (3) annulus vents openly venting on this well. No other annulus vents were noted venting at this inspection. No violations noted at the time of this inspection.
2808926 Primary Facility 2018-11-29 Routine/Complete Inspection No Violations Noted Seneca Resources submitted a spud notice to the Department via the Greenport system on November 21, 2018 for the following Utica wells: 023-20238 through 023-20243.

Department representative Sue Herzing conducted a routine site inspection at Seneca Resources CRV Pad C09-G on November 29, 2018. Each 20" round 100' in length conductor was in-place for the above listed wells. In addition, there are a total of 8 producing Marcellus wells located on the pad.

Overall, the well pad was snow covered and frozen. No signs of leaks or spills were observed on the well pad.

No violations noted.

2843503 Primary Facility 2019-02-21 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was not in production (temporarily shut in). 588 psi (pounds per square inch) was showing on the production/ flow line at the time of this inspection. This well has 3 annulus vents vented to surface. The annulus vents were all tested for combustible gas with a Altair 5 x Multi gas meter. The results were the 20" x 13" tested 0% LEL (lower explosion limit) and 0% METHANE. 13" x 9" tested 0% LEL (lower explosion limit) and 0% METHANE. The 9" x 5" tested 100% LEL (lower explosion limit) and 5% METHANE. This meter was calibrated on 2-20-19. No violations noted at this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2616250 791563 2017-07-18 2017-08-16 78a91(a) Environmental Health & Safety The SRC WT 5034 83H well was drilled to total depth on June 27, 2015 under the authorization of well permit number 023-20181. No production has ever been reported for the SRC WT 5034 83H well. The well is therefore considered "abandoned" in accordance with Section 3203 of the 2012 Oil and Gas Act,

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
791563 356250 NOV - Notice of Violation 2017-08-16

For data sources see[9]