X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-023-20178

Well Details

Well ID: 37-023-20178
Loading map...
Country: United States
State: Pennsylvania
County: Cameron
Municipality: Shippen Township
Operator Name: SENECA RESOURCES CO LLC
Well Pad ID: 151772
Farm/Lease Name: SRC WT 5034 80 H
License Status: Active
Spud Date: 2015-03-07
Permit Date: 2014-10-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.571041
Longitude: -78.351258

For data sources see[1][2][3]

Well History

Date Event
2014-10-10 New Permit Application
2014-12-19 New Permit Application
2015-03-06 Performed Spud Operation
2015-05-04 Drilling Completion
2017-08-10 Perforation
2017-08-10 Performed Stage 1 of Stimulation
2017-08-11 Perforation
2017-08-11 Performed Stage 2 of Stimulation
2017-08-12 Perforation
2017-08-12 Performed Stage 3 of Stimulation
2017-08-12 Performed Stage 4 of Stimulation
2017-08-13 Perforation
2017-08-13 Performed Stage 5 of Stimulation
2017-08-14 Perforation
2017-08-14 Performed Stage 6 of Stimulation
2017-08-14 Performed Stage 7 of Stimulation
2017-08-14 Performed Stage 8 of Stimulation
2017-08-15 Perforation
2017-08-15 Performed Stage 10 of Stimulation
2017-08-15 Performed Stage 11 of Stimulation
2017-08-15 Performed Stage 9 of Stimulation
2017-08-16 Perforation
2017-08-16 Performed Stage 12 of Stimulation
2017-08-16 Performed Stage 13 of Stimulation
2017-08-16 Performed Stage 14 of Stimulation
2017-08-17 Perforation
2017-08-17 Performed Stage 15 of Stimulation
2017-08-17 Performed Stage 16 of Stimulation
2017-08-17 Performed Stage 17 of Stimulation
2017-08-17 Performed Stage 18 of Stimulation
2017-08-18 Perforation
2017-08-18 Performed Stage 19 of Stimulation
2017-08-19 Perforation
2017-08-19 Performed Stage 20 of Stimulation
2017-08-19 Performed Stage 21 of Stimulation
2017-08-19 Performed Stage 22 of Stimulation
2017-08-20 Perforation
2017-08-20 Performed Stage 23 of Stimulation
2017-08-20 Performed Stage 24 of Stimulation
2017-08-20 Performed Stage 25 of Stimulation
2017-08-21 Perforation
2017-08-21 Performed Stage 26 of Stimulation
2017-08-21 Performed Stage 27 of Stimulation
2017-08-21 Performed Stage 28 of Stimulation
2017-08-21 Performed Stage 29 of Stimulation
2017-08-22 Perforation
2017-08-22 Performed Stage 30 of Stimulation
2017-08-22 Performed Stage 31 of Stimulation
2017-08-22 Performed Stage 32 of Stimulation
2017-08-22 Performed Stage 33 of Stimulation
2017-08-23 Perforation
2017-08-23 Performed Stage 34 of Stimulation
2017-08-23 Performed Stage 35 of Stimulation
2017-08-23 Performed Stage 36 of Stimulation
2017-08-24 Performed Stage 37 of Stimulation
2020-02-24 Deviated

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-08-10 2017-08-24 5,347 8,818,490 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 DustProof (Proppant) Keane Proppant Crystalline silica: Quartz (SiO2) 14808-60-7 99.9 11.4374 9,572,290.0
Blend Proprietary 0.1 0.0114488 9581.87
KSI-19 NW Keane Scale Inhibitor Aqueous Solution Proprietary 100 0.0108027 9041.14
MBC-516 Keane Biocide gluteral 111-30-8 26.7 0.00231176 1934.78
quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1 5.3 0.000459755 384.783
Didecyl dimethyl ammonium chloride 7173-51-5 8 0.000690065 577.537
ethanol 64-17-5 2.8 0.000242432 202.899
Water (Clean - Acid - Chems) Seneca Resources Carrier/Base Fluid Water 7732-18-5 100 87.9287 73,590,300.0
KFR-20 Keane Friction Reducer Ammonium Chloride 12125-02-9 1 0.00087689 733.896
oleic acid diethanolamide 93-83-4 2 0.00175378 1467.79
Water 7732-18-5 45 0.03946 33025.3
Mineral oil/ light hydrotreated pet. distillate 64742-47-8 20 0.0175378 14677.9
cololymer of 2-propenamide 69418-26-4 30 0.0263067 22016.9
Alcohols, C12-16, ethoxylated 68551-12-2 2 0.00175378 1467.79
KFEAC-30 Keane Iron Control Acetic acid 64-19-7 60 0.000507438 424.691
Citric acid 77-92-9 40 0.000338292 283.127
KAI-12 Keane Acid Inhibitor ethylbenzene 100-41-4 1 0.00001335 11.176
fatty imidazoline 61790-69-0 5 0.00006677 55.88
prop-2-yn-1-0l 107-19-7 5 0.00006677 55.88
xylne 1330-20-7 5 0.00006677 55.88
methanol 67-56-1 90 0.00120183 1005.85
propan-2-ol 67-63-0 5 0.00006677 55.88
alcohols, c7-9-0so, c8-rich 68526-83-0 5 0.00006677 55.88
7.5% Acid Keane Acidizing Water 7732-18-5 92.5 0.474641 397242
Hydrochloric Acid 7647-01-0 7.5 0.0384844 32208.8

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2017-08-10 1 Ottawa 994,357 8,310 8,150
2017-08-11 2 Ottawa 994,357 8,427 5,859
2017-08-12 3 Ottawa 994,357 7,730 4,428
2017-08-12 4 Ottawa 994,357 8,059 4,766
2017-08-13 5 Ottawa 994,357 8,125 4,622
2017-08-14 6 Ottawa 994,357 7,981 4,828
2017-08-14 7 Ottawa 994,357 8,024 5,554
2017-08-14 8 Ottawa 994,357 7,890 5,616
2017-08-15 9 Ottawa 994,357 7,791 5,481
2017-08-15 10 Ottawa 994,357 8,146 5,499
2017-08-15 11 Ottawa 994,357 8,238 5,643
2017-08-16 12 Ottawa 994,357 8,199 5,336
2017-08-16 13 Ottawa 994,357 8,202 5,829
2017-08-16 14 Ottawa 994,357 8,095 5,462
2017-08-17 15 Ottawa 994,357 8,034 5,742
2017-08-17 16 Ottawa 994,357 7,915 5,538
2017-08-17 17 Ottawa 994,357 7,432 5,628
2017-08-17 18 Ottawa 994,357 7,604 5,448
2017-08-18 19 Ottawa 994,357 7,915 5,278
2017-08-19 20 Ottawa 994,357 7,115 5,162
2017-08-19 21 Ottawa 994,357 7,469 4,966
2017-08-19 22 Ottawa 994,357 7,317 5,390
2017-08-20 23 Ottawa 994,357 7,368 6,044
2017-08-20 24 Ottawa 994,357 6,875 5,868
2017-08-20 25 Ottawa 994,357 6,735 5,058
2017-08-21 26 Ottawa 994,357 6,698 5,189
2017-08-21 27 Ottawa 994,357 6,631 4,044
2017-08-21 28 Ottawa 994,357 6,635 4,319
2017-08-21 29 Ottawa 994,357 6,500 4,779
2017-08-22 30 Ottawa 994,357 6,470 5,187
2017-08-22 31 Ottawa 994,357 6,590 5,064
2017-08-22 32 Ottawa 994,357 6,558 4,664
2017-08-22 33 Ottawa 994,357 6,579 4,761
2017-08-23 34 Ottawa 994,357 6,446 4,904
2017-08-23 35 Ottawa 994,357 6,395 4,866
2017-08-23 36 Ottawa 994,357 5,978 4,842
2017-08-24 37 Ottawa 994,357 6,152 4,343

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2015 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2016 SENECA RESOURCES CO LLC 0.00 0 0.00 0 0.00 0
2017 SENECA RESOURCES CO LLC 106,212.21 59 0.00 0 0.00 0
2018 SENECA RESOURCES CO LLC 357,654.43 364 0.00 0 0.00 0
2019 SENECA RESOURCES CO LLC 263,536.48 355 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2015 SENECA RESOURCES CO LLC Drill Cuttings 1,334.19 Tons LANDFILL 100361
2016 SENECA RESOURCES CO LLC Synthetic Liner Materials 3.21 Tons LANDFILL 100361
2016 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 96.00 Bbl REUSE OTHER THAN ROAD SPREADING
2016 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 25.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW005
2016 SENECA RESOURCES CO LLC Servicing Fluid 96.25 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2016 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 165.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW011
2017 SENECA RESOURCES CO LLC Produced Fluid 49,929.73 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 55.00 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Synthetic Liner Materials 0.73 Tons LANDFILL 100361
2017 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 318.43 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2017 SENECA RESOURCES CO LLC Unused Fracturing Fluid Waste 279.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 SENECA RESOURCES CO LLC Produced Fluid 79.00 Bbl REUSE (AT WELL PAD)
2017 SENECA RESOURCES CO LLC Produced Fluid 162.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2017 SENECA RESOURCES CO LLC Waste Water Treatment Sludge 32.93 Tons RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2018 SENECA RESOURCES CO LLC Produced Fluid 50,531.38 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Soil Contaminated by Oil & Gas Related Spills 8.24 Tons LANDFILL 100361
2018 SENECA RESOURCES CO LLC Produced Fluid 208.75 Bbl INJECTION DISPOSAL WELL PAS2D025BELK
2018 SENECA RESOURCES CO LLC Soil Contaminated by Oil 8.24 Tons LANDFILL 100361
2018 SENECA RESOURCES CO LLC Produced Fluid 131.25 Bbl REUSE (AT WELL PAD)
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 1.25 Bbl INJECTION DISPOSAL WELL PAS2D025BELK
2018 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 331.29 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2018 SENECA RESOURCES CO LLC Synthetic Liner Materials 0.50 Tons LANDFILL 100361
2018 SENECA RESOURCES CO LLC Produced Fluid 12.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Synthetic Liner Materials 0.26 Tons LANDFILL 100361
2019 SENECA RESOURCES CO LLC Produced Fluid 15,638.20 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 641.09 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW011
2019 SENECA RESOURCES CO LLC Produced Fluid 491.08 Bbl INJECTION DISPOSAL WELL PAS2D025BELK
2019 SENECA RESOURCES CO LLC Produced Fluid 183.50 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Other Oil & Gas Wastes 111.32 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW005
2019 SENECA RESOURCES CO LLC Produced Fluid 225.25 Bbl REUSE (AT WELL PAD)

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2351136 Primary Facility 2015-03-11 Routine/Complete Inspection No Violations Noted
2351795 Primary Facility 2015-03-12 Drilling/Alteration No Violations Noted At the time of inspection Sunny sky ~12” snow cover and ~27° F.
2355682 Primary Facility 2015-03-25 Drilling/Alteration No Violations Noted At the time of inspection Cloudy sky, light rain and ~33° F.
2357079 Primary Facility 2015-04-01 Routine/Complete Inspection No Violations Noted
2358077 Primary Facility 2015-04-02 Routine/Complete Inspection No Violations Noted
2359969 Primary Facility 2015-04-07 Routine/Complete Inspection No Violations Noted At the time of inspection cloudy sky, light rain and ~45° F.
2365280 Primary Facility 2015-04-23 Routine/Complete Inspection No Violations Noted
2378094 Primary Facility 2015-06-05 Drilling/Alteration No Violations Noted At the time of inspection sunny sky, ~ 70° F.
2432277 Primary Facility 2015-12-08 Routine/Complete Inspection No Violations Noted
2470519 Primary Facility 2016-03-30 Routine/Complete Inspection No Violations Noted
2474106 Primary Facility 2016-04-12 Routine/Complete Inspection No Violations Noted
2506060 Primary Facility 2016-07-27 Routine/Complete Inspection No Violations Noted
2610265 Primary Facility 2017-06-13 Routine/Complete Inspection No Violations Noted
2616241 Primary Facility 2017-07-18 Administrative/File Review Violation(s) Noted Administrative Inspection Record created for the purpose of entering Enforcement Record for failure to plug an abandoned well.
2622108 Primary Facility 2017-07-26 Routine/Complete Inspection No Violations Noted Routine inspection of Seneca Resources Corp CRV PAD C09-G on July 26, 2017. No one was onsite during my inspection.

Rig mats remain onsite with a total of 25 produced fluids frac containers. It appears that the operator is gearing up for well stimulation. All wells are labeled with the well number and operator. A total of 9 wells have been TD. Well 023-20182 has been drilled and plugged.

There are 6 produced fluids silos located in secondary containment onsite. Field screen reading for specific conductance within this containment was 82.0 uS/cm.

Overall, the pad is in good condition and all necessary BMPs are in place surrounding the well pad.

The sign located at the entrance to the well pad only has a total of 7 well listed. This does not match with the number of drilled wells onsite. I recommend updating the well site to reflect the number of drilled wells onsite.

2627511 Primary Facility 2017-08-18 Routine/Complete Inspection No Violations Noted Routine inspection of Seneca Resources Corp CRV PAD C09-G on August 17, 2017 with company man Adam Pierce of Seneca Resources.

Crews were currently working on fracing Marcellus wells 023-20178, 023-20179, 023-20183, and 023-20184. The fracing crew was approximately half way done with fracing these four wells. Once finished they will move the rig over and work on stimulating Marcellus wells 023-20180, 023-20181, 023-20182, and 023-20198. According to Mr. Pierce, crews are installing a perforation string downhole and with 8 perforation holes per every 2 ft. section of the string. Plugs made of a composite are being placed between 190 ft. perforation stages.

Sand is being hauled via trucks from the Cameron County rail yard. Water used for stimulation is being transferred to this pad via the above ground water line from the Clermont Water Treatment Facility. The above ground waterline is plumbed into a series of manifolded frac tanks.

All equipment is placed on secondary containment. Overall, the pad is i

2630935 Primary Facility 2017-08-15 Routine/Complete Inspection No Violations Noted
2643022 Primary Facility 2017-09-28 Routine/Complete Inspection No Violations Noted Routine inspection of Seneca Resources Corp CRV PAD C09-G on September 28, 2017 with company man Scott Digel of Seneca Resources.

Crews were currently working on fracing Marcellus wells 023-20182, 023-20183, and 023-20184. The fracing crew was almost completed with well stimulation on these 3 wells. Stimulation been completed on wells 023-20178, 023-20179, 023-29180, 023-20181, and 023-20198. According to Mr. Digel, once all of the wells have been stimulated, crews will remove this rig and bring in 2 work-over rigs to drill out the plugs on the above mentioned wells.

Sand is being hauled via trucks from the Cameron County rail yard, then being trucked to this site. Water used for well stimulation is being transferred to this pad via the above ground water line from the Clermont Water Treatment Facility. The above ground waterline is plumbed into a series of manifolded frac tanks. These tanks are located along the Eastern border of the pad.

All equipment is placed on secondary containment. Overall, th

2668316 Primary Facility 2017-12-06 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The tubing pressure (production) was 1058 psi. at this inspection. All fittings and vented annulus, 20x13, 13x9 and the 9x5 were checked at this inspection. The pad and well area were neat and organized.
2672440 Primary Facility 2017-12-15 Routine/Complete Inspection No Violations Noted Routine inspection of Seneca Resources CRV PAD C09-G on December 15, 2017.

There are a total of 8 producing Marcellus wells located on this pad. Rig mats from the recent flowback operation have been removed and are currently being stationed along the N edge of the well pad. There is one frac tank stationed on man-made secondary containment with a berm near the well heads. There are 4 frac tanks located near the produced fluids containment along the S border. These frac tanks are currently not located in secondary containment nor to they appear to be connected to anything. There are (6) 400 BBL produced fluids tanks located in modular secondary containment. Water within the containment is frozen and snow covered. In addition, there's a row of 22 frac tanks stationed along the E edge of the well pad. This series of 22 frac tanks are stationed in secondary man made containment with a berm. There are 8 gas production units stationed along the W edge of the well pad.

The pad and surrounding areas are snow cove

2707894 Primary Facility 2018-03-20 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. The wellhead assembly, annulus vents 20" x 13 3/8", 13 3/8" x 9 5/8" and 9 5/8" x 5 1/2" were tested for gas. Results of this testing was that 100% LEL(lower explosion limit) and 24% Methane was detected on the 9 5/8" x 5 1/2" annulus vent. No other gas was detected on the wellhead assembly or the well area.
2734533 Primary Facility 2018-05-24 Incident- Response to Accident or Event Violation(s) Noted I arrived onsite and met with Jeff Passarello of Seneca in response to a spill report. Between 3 and 4 AM on 5/24, a worker on the site set up to pump produced water from both the Baker tank battery and the production tanks to the Clermont storage facility. The same pump is used to pump water from the well cellars (when needed) along with the produced water, but no pumping was occurring at the cellars. A water line is left in place to the cellars, but capped ~20' from the cellars to allow vehicle traffic through. When the worker turned on the pump, the cap popped off of the water line to the cellars and spilled ~1 1/2 barrels of produced water from the pump to the pad surface. When I arrived, approximately a third to a half of the spill area had already been excavated and a 30 yard dumpster filled. Jeff informed me that they were waiting on another rolloff to continue the excavation. The gravel was underlain by a clay layer, making visual confirmation of the spill removal possible, but Jeff was also u
2792263 Primary Facility 2018-10-16 Routine/Complete Inspection No Violations Noted Department representative Sue Herzing conducted a routine site inspection at Seneca Resources CRV C09-G Well Pad on October 16, 2018. There are a total of 8 drilled and producing wells located on this well pad. All well heads are properly tagged. Well cellars are full of water. No bubbling or sheen observed in the cellars. There are (6) 400 bbl. produced fluids tanks stationed in secondary containment. Approximately 1" of rain water was found in the produced fluids secondary containment with a conductivity reading of 78.8 uS/cm. A series of 12 manifolded frac tanks are being stationed on secondary along the NE edge of the well pad. Just a trace of water was observed within this containment. Overall, the well site looks good. No violations noted.
2807474 Primary Facility 2018-11-28 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. There are two (3) annulus vents openly venting on this well. No other annulus vents were noted venting at this inspection. No violations noted at the time of this inspection.
2808915 Primary Facility 2018-11-29 Routine/Complete Inspection No Violations Noted Seneca Resources submitted a spud notice to the Department via the Greenport system on November 21, 2018 for the following Utica wells: 023-20238 through 023-20243.

Department representative Sue Herzing conducted a routine site inspection at Seneca Resources CRV Pad C09-G on November 29, 2018. Each 20" round 100' in length conductor was in-place for the above listed wells. In addition, there are a total of 8 producing Marcellus wells located on the pad.

Overall, the well pad was snow covered and frozen. No signs of leaks or spills were observed on the well pad.

No violations noted.

2843467 Primary Facility 2019-02-21 Routine/Complete Inspection No Violations Noted At the time of this inspection this well was in production. 590 psi (pounds per square inch) was showing as the production/ flow line at the time of this inspection. This well has 3 annulus vents vented to surface. The annulus vents were all tested for combustible gas with a Altair 5 x Multi gas meter. The results were the 20" x 13" tested 0% LEL (lower explosion limit) and 0% METHANE. 13" x 9" tested 0% LEL (lower explosion limit) and 0% METHANE. The 9" x 5" tested 0% LEL (lower explosion limit) and 0% METHANE. This meter was calibrated on 2-20-19. No violations noted at this inspection.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2616241 791558 2017-07-18 2017-08-16 78a91(a) Environmental Health & Safety The SRC WT 5034 80H well was drilled to total depth on May 7, 2015 under the authorization of well permit number 023-20178. No production has ever been reported for the SRC WT 5034 80H well. The well is therefore considered "abandoned" in accordance with Section 3203 of the 2012 Oil and Gas Act, 5
2734533 817671 2018-05-24 2018-07-31 CSL 402(b) Environmental Health & Safety Release of produced water to pad
2734533 817672 2018-05-24 2018-07-31 78A57(A)___ Environmental Health & Safety Release of produced water to pad
2734533 817673 2018-05-24 2018-07-31 SWMA 301 Environmental Health & Safety

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
791558 356250 NOV - Notice of Violation 2017-08-16
817671 364354 NOV - Notice of Violation 2018-08-01
817672 364354 NOV - Notice of Violation 2018-08-01
817673 364354 NOV - Notice of Violation 2018-08-01

For data sources see[9]

References