X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-021-21189

Well Details

Well ID: 37-021-21189
Loading map...
Country: United States
State: Pennsylvania
County: Cambria
Municipality: Susquehanna Township
Operator Name: SLA EXPLORATION LLC
Well Pad ID:
Farm/Lease Name: STEIN 1
License Status:
Spud Date:
Permit Date: 2012-03-01
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.707464
Longitude: -78.813720

For data sources see[1][2][3]

Well History

Date Event
2012-03-01 New Permit Application
2012-07-09 Performed Spud Operation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2012 NTS ENERGY LLC 0.00 0 0.00 0 0.00 0
2013 NTS ENERGY LLC 0.00 0 0.00 0 0.00 0
2014 NTS ENERGY LLC 0.00 0 0.00 0 0.00 0
2015 NTS ENERGY LLC 13,536.00 280 0.00 0 0.00 0
2016 NTS ENERGY LLC 4,690.00 150 0.00 0 0.00 0
2018 SLA EXPLORATION LLC 6,455.00 365 0.00 0 0.00 0
2019 HIGHPOINTE OIL & GAS LLC 2,802.34 245 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 NTS ENERGY LLC Drilling Fluid Waste 875 Bbl CENT WASTE TRT FAC NPDES PA0095443
2012 NTS ENERGY LLC Drilling Fluid Waste 230 Bbl CENT WASTE TRT FAC NPDES PA0095273
2012 NTS ENERGY LLC Drilling Fluid Waste 875.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2012 NTS ENERGY LLC Drilling Fluid Waste 230.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2013 NTS ENERGY LLC Drilling Fluid Waste 776 Bbl CENT WASTE TRT FAC NPDES PA0095443
2013 NTS ENERGY LLC Drilling Fluid Waste 776.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095443
2015 NTS ENERGY LLC Produced Fluid 80.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0101508
2015 NTS ENERGY LLC Produced Fluid 80 Bbl CENT WASTE TRT FAC NPDES PA0101508
2016 NTS ENERGY LLC Produced Fluid 30.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2018 SLA EXPLORATION LLC Produced Fluid 80.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2083861 Primary Facility 2012-07-11 Routine/Complete Inspection Violation(s) Noted Well spudded 7/9/12. At the time of this inspection, Well Id sign, permit, and ES plan present. Aces road entrance adequately rocked. It appear that access road culvert have not been properly stabilized with rock and/or vegetative growth; therefore, department is recommending that operator add a temporary stabilization to culvert ditches and outlets in order to prevent a possible pollution event. No accelerated erosion or sedimentation concerns were noted on access road, but the Potential exists hence site recently constructed. Bmp's installed according to plan down gradient from well pad (i.e. filter fence). One lined below grade pit located onsite-- according to ES plan an above grade pit was to be used due to depth to seasonal high groundwater table. Soils type primarily Cookport- department is going to further investigate soil type and determine minimum depth of groundwater table for designated soil type, until that information is verified Inspt result will remain pending, no accelerated ES at time of this inspection.
2084915 Primary Facility 2012-07-19 Routine/Complete Inspection Violation(s) & Outstanding Violations during todays inspection, it was observed that operator failed to properly install/maintain culvert ditches and outlets; therefore, a new violation is being written for failure to minimize erosion and sedimenation again for failure to design, implement and maintain ES BMP's as outline in ES plan.Operator has crew actively cleaning state road and access rd entrance at time of this inspection. Recommend that operator add additonal rock to access road in order to prevent a pollution event, as well as reduce the potential for mud reaching Peg Run Rd. Well drilled not yet equipped for prodcution. Drilling equipment actively being moved off site. One below grade lined pit with drill fluids and cuttings on site. Based on previous inspection and admin review of soil type violations were issued on previously pending report due minimum depth of seasonal high grounwater table. Operator shall remove all pit contents (fluids, cuttings, and liner) and properly dispose at an offsite facility. Dept is requestion manifests/disposal records for all wastes.
2086445 Primary Facility 2012-07-12 Drilling/Alteration No Violations Noted
2086447 Primary Facility 2012-07-11 Drilling/Alteration No Violations Noted
2089281 Primary Facility 2012-08-02 Follow-up Inspection Outstanding Violations - No Viols Req'd Site ID sign, ES plan and permit present. Access road exhibits minor erosion due to recent rainfall and heavy traffic. Well drilled not yet equipped for production. One below grade lined pit with drill fluids and cuttings on site. Previously issued violations for construction pit within seasonal high ground water table. Again, as per previous inspection report operator shall remove all pit contents (fluids, cuttings, and liner) and properly dispose at an approved offsite facility. Department is requesting that all manifests and disposal records be provided to the department upon final disposition of waste.It was observed that operator failed to properly install/maintain culvert ditches and outlets and since last inspection it does not appear that necessary measures were taken to prevent accelerated erosion events along access road; therefore previously issued violations are outstanding. Informal cmplt recieved on noises from well head as well as water flooding township roadway during heavy rain events. Dept voiced cmplt concerns with operator
2093211 Primary Facility 2012-07-16 Routine/Complete Inspection No Violations Noted Well Id sign and E&S plan were present at access road. At the time of the inspection, no E&S concerns and no freeboard issues were present at the site. NTS contracted First Class to complete the gas well. Conductor pipe (20”) was set at 34 ft. and was sanded in. 9 5/8” pipe was set at 673 feet. On 7/11/12, first cement was completed with 250 sks of Type I and no return. . Second cement job occurred on 7/14/12 and used 100 sks of Class A and 40 sks of Sypersubtropic with 80 lbs. of Bara seal. Cement was recorded to surface. Surface pipe (7”) was set at 1179’ and was cemented with 186 sacks of Type 1 with 2 bbl. return. Plug was down at 7/15/12 at 8:40 hrs. Water was recorded at 230 feet and coal was recorded at 430 ft. to 434 ft. Current depth was 1,330 feet.
2093229 Primary Facility 2012-07-23 Routine/Complete Inspection No Violations Noted Well Id sign and E&S plan were present at access road. At the time of the inspection, no E&S concerns and no freeboard issues were present at the site. Well was completed and slight gas release from piping. DEP talked to owner of property. Access road showed signs of sediment on the township road.
2109988 Primary Facility 2012-10-16 Follow-up Inspection Outstanding Violations - No Viols Req'd At the time of inspection, Site ID sign, ES plan and permit present. Well drilled not yet equipped for production. One below grade lined pit with drill fluids and cuttings on site. Previously issued a violations for construction of pit within seasonal high ground water table, as operator failed to implement ES plan as designed-where an above grade pit and/or tanks were to be utilized. Again, as per previous inspection report operator shall remove all pit contents (fluids, cuttings, and liner) and properly dispose at an approved offsite facility. Department is requesting that all manifests and disposal records be provided to the department upon final disposition of waste. Outstanding violations for failure to properly install/maintain roadside culverts and outlets is outstanding- per today's inspection access road exhibits erosion and culvert outlets are "full" of sediment. Perimeter bmp's are installed and appear to be functioning. Site appears temporarily stabilized with rock and/or bmps.
2177803 Primary Facility 2013-06-19 Follow-up Inspection Violation(s) & Outstanding Violations At time of inspection, well drilled, not yet equipped for production. Below-grade lined drill pit still on-site, contents include drill cuttings and fluids. Freeboard exceeded. Orange security fence surrounding pit compromised.
2199604 Primary Facility 2013-08-21 Follow-up Inspection Violation(s) & Outstanding Violations Follow-up to previously issued violations under inspection records 2083861, 2083861, 2084915, 2177803.
2206544 Primary Facility 2013-07-08 Administrative/File Review Outstanding Violations - No Viols Req'd Admin inspt. Department spoke to Operator representative Steve Phillips via phone to discuss violations issued under inspection record 2177803 for failure to maintain freeboard in drill pit, failure to submit well documents, and for failure to restore well site within nine months of date of TD.
2213245 Primary Facility 2013-10-02 Administrative/File Review Outstanding Violations - No Viols Req'd Admin inspt. Department spoke to Operator representative Steve Phillips via phone to discuss violations issued under inspection record 2177803 for failure to maintain freeboard in drill pit, failure to submit well documents, and for failure to restore well site within nine months of date of TD and under inspection record 2199604 for failure to permanently stabilize site as per regulation to provide protection from accelerated erosion and sedimentation.
2214094 Primary Facility 2013-10-16 Follow-up Inspection Outstanding Violations - No Viols Req'd Follow-up to previously issued violations under inspection records 2083861, 2083861, 2084915, 2177803.
2254711 Primary Facility 2014-03-18 Routine/Complete Inspection Outstanding Violations - No Viols Req'd Follow-up to previously issues violations under Inspection Records #2083861, 2084915.
2381207 Primary Facility 2015-06-09 Follow-up Inspection Outstanding Violations - No Viols Req'd FUI inspection to inspection reports #2083861, 2177803 and 2084915. Well equipped for production. Brine tank appears structurally sound. Area to right as you enter the pad area, looking toward the well head, is rocked. Per current and previous inspections, Depart requests submission of Disposal Records for drill pit that was previously constructed within seasonal high groundwater table. Site appears temporarily stabilized. Fill slope seeded and mulched, however, 70% uniform vegetative growth not yet achieved. Depart recommends Operator repair and continue to monitor and maintain temporary BMP's. Previous E&S issues addressed at this site; no new E&S issues observed on site or access road. Outstanding violations still exist for this site.
2382718 Primary Facility 2015-06-17 Administrative/File Review Outstanding Violations - No Viols Req'd Admin. Inspection in response to follow-up phone call with Operator regarding inspection ID # 2381207. Department left phone message for Operator on 6-17-15. Operator returned call later that morning. Department recommended Operator maintain temporary BMP’s at site until 70% growth is achieved, and remove when permanent stabilization achieved. Department recommended Operator submit restoration report as requested from previous inspections. No E&S issues on site or access road.
2438993 Primary Facility 2015-12-09 Routine/Complete Inspection No Violations Noted At the time of inspection, well was in production. No issues at the site.
2468471 Primary Facility 2016-03-23 Routine/Complete Inspection No Violations Noted no issues. gas well in production.
2472708 Primary Facility 2016-03-25 Follow-up Inspection Outstanding Violations - No Viols Req'd FUI to previous Inspections where vios issued for failure to implement E&S plan & failure to implement & maintain BMP’s, failure to restore site w/i 9 months, and failure to achieve perm stabilization. At time of inspection AR rocked. Culvert pipe at top of AR near well pad appears unmaintained. Well equipped for production. Well tag present. Brine tank appears structurally sound. Site appears temporarily stabilized. Temp BMP’s remain down gradient of site. Dept recommends Opr remove temp BMP’s from site since permanent stabilization achieved. Piping and uninstalled silt fence remain on site. Depart recommends Opr remove equipment not necessary for production from site.Written response to NOV & previously requested manifest and disposal records for pit liner and pit contents not received by Depart. Previously issued vio for failure to achieve permanent stabilization has self-corrected.Previously issued vios for failure to implement E&S plan, failure to maintain BMP's, and failure to restore site within 9 mon
2647629 Primary Facility 2017-10-16 Routine/Complete Inspection No Violations Noted system running no issues
2656156 Primary Facility 2017-11-01 Compliance Evaluation No Violations Noted Compliance Evaluation Inspection to inspection record #2083861, #2084915, #2177803, and #2199604.

Well appears to be in production. Violations issued under the above inspection record #'s have been corrected.

2658391 Primary Facility 2017-11-08 Routine/Complete Inspection No Violations Noted System producing. No,issues at the time of visit
2665910 Primary Facility 2017-11-20 Administrative/File Review No Violations Noted ADMIN inspection to inspection record #2656156.

Above mentioned inspection returned to Department by USPS as 'not deliverable as addressed'. Inspection re-mailed to Home, PA address. Department recommends operator update records to reflect current address.

2681278 Primary Facility 2018-01-11 Routine/Complete Inspection No Violations Noted System running no issues. Well tag present. Emergency contact sign present.
2688261 Primary Facility 2018-01-29 Administrative/File Review No Violations Noted ADMIN Inspection. Department received Well Site Restoration Report via email from operator rep Steve Phillips. This Restoration Report is administratively incomplete. Department recommends operator resubmit Restoration Report.
2691466 Primary Facility 2018-02-05 Administrative/File Review No Violations Noted ADMIN inspection. Department received well site restoration report from operator via email.

Previously issued violations for this site were corrected on 3-25-16 and 11-1-17.

2810115 Primary Facility 2018-12-04 Routine/Complete Inspection No Violations Noted Well was in production.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2083861 644333 07/11/2012 2012-07-11 78.56PITCNST - Impoundment not structurally sound, impermeable, 3rd party protected, greater than 20" of seasonal high ground water table Administrative
2084915 644515 07/19/2012 2012-07-19 102.4 - Failure to minimize accelerated erosion, implement E&S plan, maintain E&S controls. Failure to stabilize site until total site restoration under OGA Sec 206(c)(d) Environmental Health & Safety
2177803 671454 06/19/2013 2013-06-19 78.56(2) - Failure to maintain 2 ' of freeboard in an impoundment. Administrative self corrected/pit removed
2177803 671455 06/19/2013 2013-06-19 206C - Failure to restore well site within nine months after completion of drilling, failure to remove all pits, drilling supplies and equipment not needed for production. Administrative
2199604 676260 08/21/2013 2013-08-21 102.22 - Failure to achieve permanent stabilization of earth disturbance activity. Administrative

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
644333 286123 NOV - Notice of Violation
644515 286196 NOV - Notice of Violation
671454 299210 NOV - Notice of Violation Comply/Closed 2017-11-02
671455 299210 NOV - Notice of Violation Comply/Closed 2017-11-02
676260 301329 NOV - Notice of Violation Comply/Closed 2017-11-02

For data sources see[7]

References