If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-021-21184 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.616453,"lon":-78.729883,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Cambria | |
Municipality: West Carroll Township | |
Operator Name: SLA EXPLORATION LLC | |
Well Pad ID: | |
Farm/Lease Name: LOWMASTER 1-5 | |
License Status: | |
Spud Date: | |
Permit Date: 2011-11-10 | |
Well Type: GAS | |
Unconventional Well: N | |
Configuration: Vertical Well | |
Conservation: No | |
Latitude: 40.616453 | |
Longitude: -78.729883 |
Date | Event |
---|---|
2011-11-10 | New Permit Application |
2012-01-10 | Performed Spud Operation |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2011 | NTS ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | NTS ENERGY LLC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | NTS ENERGY LLC | 5,331.00 | 120 | 0.00 | 0 | 0.00 | 0 |
2014 | NTS ENERGY LLC | 10,154.00 | 210 | 0.00 | 0 | 0.00 | 0 |
2015 | NTS ENERGY LLC | 9,892.00 | 360 | 0.00 | 0 | 0.00 | 0 |
2016 | NTS ENERGY LLC | 3,011.00 | 120 | 0.00 | 0 | 0.00 | 0 |
2018 | SLA EXPLORATION LLC | 6,121.00 | 365 | 0.00 | 0 | 0.00 | 0 |
2019 | HIGHPOINTE OIL & GAS LLC | 1,964.00 | 122 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | NTS ENERGY LLC | Fracing Fluid Waste | 780 Bbl | CENT WASTE TRT FAC NPDES | PA0095273 |
2012 | NTS ENERGY LLC | Drilling Fluid Waste | 380 Bbl | CENT WASTE TRT FAC NPDES | PA0095443 |
2012 | NTS ENERGY LLC | Fracing Fluid Waste | 780.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2012 | NTS ENERGY LLC | Fracing Fluid Waste | 80 Bbl | CENT WASTE TRT FAC NPDES | PA0095443 |
2012 | NTS ENERGY LLC | Drilling Fluid Waste | 380.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095443 |
2012 | NTS ENERGY LLC | Fracing Fluid Waste | 80.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095443 |
2015 | NTS ENERGY LLC | Produced Fluid | 35 Bbl | CENT WASTE TRT FAC NPDES | PA0095273 |
2015 | NTS ENERGY LLC | Produced Fluid | 35.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2016 | NTS ENERGY LLC | Produced Fluid | 80.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
2018 | SLA EXPLORATION LLC | Produced Fluid | 140.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | PA0095273 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2033276 | Primary Facility | 2012-01-11 | Drilling/Alteration | No Violations Noted | Well Id sign and E&S plan were present at access road. At the time of the inspection, no E&S concerns and no freeboard at the pit were present at the site. Filter fence was located on down gradient side of site. Phillips was contracted by NTS. Conductor pipe (20¿ pipe) was set at 34 feet and was sanded in. No mine shaft or void was encountered. Mine casing (13 3/8¿ pipe) was set at 211 feet with no cement basket. 180 sacks of Type 1 were used to cement mine casing with 2 bbls returns. Plug was down at 10:15 am at 1/11/12. Universal completed the cementing of the well. Phillips was allowing the 8 hours cement set time. The anticipated depth of water protection casing (9 5/8¿) was set at 500 feet. |
2034207 | Primary Facility | 2011-01-13 | Drilling/Alteration | No Violations Noted | Well Id sign and E&S plan were present at access road. At the time of the inspection, no E&S concerns and no freeboard at the pit were present at the site. Filter fence was located on down gradient side of site. Phillips was contracted by NTS. Water protection casing (9 5/8¿) was set at 463 feet and was cemented with 160 sacks of Type I and 5 bbls of return. Plug was down at 07:30 at 1/12/12. Intermediate casing (7¿) was set at 968 feet and was cemented with 180 sacks of Type I and 7 bbls of return. Plug was down at 23:50 hours on 1/12/12. Phillips was preparing the BOP connection. Coal intervals were recorded at 90¿ to 94¿, 160¿ to 164¿, 285¿ to 292¿ and 305¿to 315¿ and 325¿ to 330¿. |
2035245 | Primary Facility | 2012-01-19 | Drilling/Alteration | No Violations Noted | Well Id sign and E&S plan were present at access road. At the time of the inspection, no E&S concerns and no freeboard at the pit were present at the site. Filter fence was located on down gradient side of site. Phillips had completed well to 5200¿. Phillips was repairing the double pump on the rig. |
2036815 | Primary Facility | 2012-01-12 | Routine/Complete Inspection | No Violations Noted | Site visit was part of routine inspection. |
2047113 | Primary Facility | 2012-03-02 | Routine/Complete Inspection | No Violations Noted | At the time of this inspection, well site ID sign and ES plan onsite. Well Spudded 1/10/12. |
2211980 | Primary Facility | 2013-10-07 | Routine/Complete Inspection | No Violations Noted | At time of inspection, well equipped for production. Dept. does not observe accelerated erosion or sedimentation issues on well site or access road at this time. Access road in good condition and adequately rocked. Brine tank appears to be sound. Well tag was not legible during inspection. Dept. recommends operator replace well tag. |
2353855 | Primary Facility | 2015-03-12 | Routine/Complete Inspection | Violation(s) Noted | At time of inspection, well appears drilled and equipped for production. Brine tank appears sound. Shared access road plowed. |
2372813 | Primary Facility | 2015-05-15 | Routine/Complete Inspection | No Violations Noted | At the time of the inspection, no E&S concerns. Gas well was in production. |
2376012 | Primary Facility | 2015-06-01 | Follow-up Inspection | Outstanding Violations - No Viols Req'd | On-site inspection conducted as follow-up to inspection record 2353855 (enf ID 321128) for failure to install well tag in a legible, visible, and permanent manner and for failure to submit a well site restoration report.At time of inspection, well appears drilled and equipped for production. Brine tank appears sound. Well tag present, legible.Shared access road stable.Located adjacent to ag field.No accelerated E&S issues noted at this time.To date, the well site restoration report has not yet been received by the Department.Violations issued under 3211(h) for failure to install the well tag on the well in a legible, visible, and permanent manner have been corrected. Violations issued under 78.65(3) for failure to submit a well site restoration report remain outstanding. Add'l comments on paper SAIR. |
2466681 | Primary Facility | 2016-03-17 | Routine/Complete Inspection | No Violations Noted | At the time of the inspection, no E&S concerns. Gas well was in production. |
2603798 | Primary Facility | 2017-06-01 | Routine/Complete Inspection | No Violations Noted | system running. no issues |
2633363 | Primary Facility | 2017-09-07 | Routine/Complete Inspection | No Violations Noted | |
2655932 | Primary Facility | 2017-11-01 | Follow-up Inspection | Outstanding Violations - Viols Req'd | Follow up inspection to inspection record #2353855.
Well appears equipped for production. Violation for failure to submit the well site restoration report remains outstanding. |
2662402 | Primary Facility | 2017-11-20 | Administrative/File Review | In Compliance with Policy | ADMIN inspection to inspection record #2655932.
Above mentioned inspection returned to Department by USPS as 'not deliverable as addressed'. Inspection re-mailed to Home, PA address. Department recommends operator update records to reflect current address. Previously issued violation for failure to submit well site restoration report remains outstanding |
2678131 | Primary Facility | 2018-01-04 | Routine/Complete Inspection | No Violations Noted | System running no issues. Well tag present. Emergency contact sign present. |
2688253 | Primary Facility | 2018-01-29 | Administrative/File Review | Outstanding Violations - Viols Req'd | ADMIN Inspection to inspection record #2353855. Department received Well Site Restoration Report via email from operator rep Steve Phillips. This Restoration Report is administratively incomplete. Department recommends operator resubmit Restoration Report.
Previously issued violation still exists for this site. |
2691465 | Primary Facility | 2018-02-05 | Compliance Evaluation | No Violations Noted | CEI to inspection record #2353855. Department received well site restoration report from operator via email. Operator appears in compliance at this time.
Previously issued violation under inspection record #2353855 for failure to submit well site restoration report has been corrected and closed. |
2698015 | Primary Facility | 2018-02-26 | Routine/Complete Inspection | No Violations Noted | Well tag present and emergency contact information present. No issues at the site |
2725774 | Primary Facility | 2018-05-03 | Routine/Complete Inspection | No Violations Noted | Well was in production. Well tag and emergency contact present. No issues at the site |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2353855 | 718168 | 03/12/2015 | 2015-03-12 | 78.65(3) - SITE RESTORATION - Owner or operator failed to submit a well site restoration report to the Department within 60 days after restoration of the well site. | Administrative | |
2353855 | 718169 | 03/12/2015 | 2015-03-12 | OGA3211(H) - WELL PERMITS - LABELING - Failure to install, in a permanent manner, the permit number on a completed well. | Administrative | |
2655932 | 801111 | 2017-11-01 | 78.65(3) | Administrative | Violation issued 3-12-15. This violation remains outstanding. | |
2688253 | 807034 | 2015-03-12 | 2018-02-05 | 78.65(3) | Administrative |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
718168 | 321128 | NOV - Notice of Violation | Comply/Closed | 2018-02-08 | |||
718169 | 321128 | NOV - Notice of Violation | Comply/Closed | 2018-02-08 |
For data sources see[7]