37-019-21634

Well Details

Well ID: 37-019-21634
Loading map...
Country: United States
State: Pennsylvania
County: Butler
Municipality: Winfield Township
Operator Name: SNYDER BROS INC
Well Pad ID: 146816
Farm/Lease Name: CONCORDIA LUTH MINISTRIES 1 679
License Status:
Spud Date:
Permit Date: 2009-06-12
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 40.753553
Longitude: -79.783327

For data sources see[1][2][3]

Well History

Date Event
2009-06-12 New Permit Application
2009-08-21 Performed Spud Operation
2009-09-01 Drilling Completion
2010-01-20 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 SNYDER BROS INC 3,676.00 24 0.00 0 0.00 0
2011 SNYDER BROS INC 32,593.00 195 0.00 0 0.00 0
2012 SNYDER BROS INC 19,125.00 305 0.00 0 0.00 0
2013 SNYDER BROS INC 47,543.00 359 0.00 0 0.00 0
2014 SNYDER BROS INC 25,649.00 348 0.00 0 0.00 0
2015 SNYDER BROS INC 14,507.00 234 0.00 0 0.00 0
2016 SNYDER BROS INC 2,058.00 69 0.00 0 0.00 0
2017 SNYDER BROS INC 5,052.00 89 0.00 0 0.00 0
2018 SNYDER BROS INC 19,766.00 327 0.00 0 0.00 0
2019 SNYDER BROS INC 9,311.00 321 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 SNYDER BROS INC Produced Fluid 536.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2010 SNYDER BROS INC Produced Fluid 1,690.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 SNYDER BROS INC Produced Fluid 320.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011 SNYDER BROS INC Produced Fluid 310.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2012 SNYDER BROS INC Produced Fluid 80.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2013 SNYDER BROS INC Produced Fluid 454.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2013 SNYDER BROS INC Produced Fluid 320.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2013 SNYDER BROS INC Produced Fluid 175.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW006
2014 SNYDER BROS INC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW005
2014 SNYDER BROS INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-23759
2014 SNYDER BROS INC Produced Fluid 120.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2014 SNYDER BROS INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2015 SNYDER BROS INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2018 SNYDER BROS INC Produced Fluid 100.00 Bbl INJECTION DISPOSAL WELL 34-099-23158
2019 SNYDER BROS INC Produced Fluid 183.00 Bbl INJECTION DISPOSAL WELL 34-099-23158

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1822868 Primary Facility 2009-08-25 Drilling/Alteration No Violations Noted
1823966 Primary Facility 2009-08-28 Drilling/Alteration No Violations Noted
1824380 Primary Facility 2009-08-31 Drilling/Alteration No Violations Noted
1828194 Primary Facility 2009-09-15 Routine/Complete Inspection No Violations Noted
1886265 Primary Facility 2010-05-19 Routine/Complete Inspection No Violations Noted
1923776 Primary Facility 2010-10-05 Site Restoration No Violations Noted Well in production. 70% plus perennial vegetative cover. All pits returned to grade.
1992095 Primary Facility 2011-07-29 Routine/Partial Inspection No Violations Noted
2675966 Primary Facility 2017-12-21 Routine/Partial Inspection No Violations Noted At the time of inspection, well was shut-in. Based on production reporting, it has been shut in since May 2017. Well integrity was in good condition, with no signs of any leaks or spills at the site. Corrosion was only superficial rust. A vent for the annulus was open. The well was labeled and the Emergency Response sign was posted at the access road entrance. The chart was last changed on 11/29/2017. A gauge was reading 1500 psi along the production line before the valve that was closed. There were also 2 fiberglass tanks at the site with 2 separators hooked in to them.

For data sources see[7]