37-015-23430

Well Details

Well ID: 37-015-23430
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Overton Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 153744
Farm/Lease Name: RAIMO EAST UNIT 1H
License Status:
Spud Date:
Permit Date: 2018-05-08
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.662603
Longitude: -76.528008

For data sources see[1][2][3]

Well History

Date Event
2018-05-08 New Permit Application
2018-09-12 Performed Spud Operation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2019 CHIEF OIL & GAS LLC 4,140,776.56 185 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 CHIEF OIL & GAS LLC Drill Cuttings 179.53 Tons LANDFILL 301358
2019 CHIEF OIL & GAS LLC Produced Fluid 720.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 CHIEF OIL & GAS LLC Synthetic Liner Materials 9.84 Tons LANDFILL 301358
2019 CHIEF OIL & GAS LLC Drill Cuttings 1,401.38 Tons LANDFILL 301358
2019 CHIEF OIL & GAS LLC Soil Contaminated by Oil 56.27 Tons LANDFILL 301358
2019 CHIEF OIL & GAS LLC Soil Contaminated by Oil & Gas Related Spills 56.27 Tons LANDFILL 301358
2019 CHIEF OIL & GAS LLC Produced Fluid 35,711.43 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2786395 Primary Facility 2018-10-09 Routine/Complete Inspection No Violations Noted Weather was 74° and sunny at time of inspection. There were no Chief representatives on location at time of inspection. Well is a spud conductor only. Conductor casing was cemented in to surface. Mouse hole was also set and covered with a steel plate at time of inspection. No violations were noted at time of inspection.
2811972 Primary Facility 2018-12-06 Routine/Complete Inspection No Violations Noted I met Trey Villareal, Jeremy Boyd, and Billy Swanson when I arrived. Precision rig 569 was on location, drilling the surface hole on the East 1H well. Containments appeared to be in excellent condition, site housekeeping was good.
2842966 Primary Facility 2019-02-19 Incident- Response to Accident or Event No Violations Noted On February 19, 2019, the Department conducted an investigation on the Chief Oil & Gas LLC Raimo Pad. A split hose caused a spill of base oil outside of containment off the well pad. The operator estimates about 1 bbl of base oil had spilled. At the time of inspection, the soil of the impacted area has been excavated. The soil has been placed in covered roll-off containers. The excavated area did not appear to have any visually impacted soil remaining. The Department spoke with Jeremy Watson with Chief Oil & Gas LLC. He said that Waste Management was coming to do a profile of the contaminated soil and haul it away.

During the investigation, the operator was cleaning and removing timber mats. There was a vac truck onsite to remove the wash water out of the spill containment.

The Department spoke with Peg Farrell on the phone. The Department discussed that the Act 2 process should be started.

The release of base oil of the well pad is a violation of CSL 402(b), 78a 56(a), and SWMA 301.

For data sources see[7]

References