Well Details

Well ID: 37-015-23399
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Leroy Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 154876
Farm/Lease Name: SGL-12 N WEST UNIT 3H
License Status:
Spud Date:
Permit Date: 2018-02-07
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.660583
Longitude: -76.679042

For data sources see[1][2][3]

Well History

Date Event
2018-02-07 New Permit Application
2018-06-25 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2019-01-14 2019-02-14 8,210 14,629,900 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 FR-11 Chemplex, Salvoy Group Friction Reducer Listed Below
Unihib G GeoSafe Acid Inhibitor Listed Below
BIOC11219A Nalco Champion Biocide Listed Below
Hydrochloric Acid PVS Acidizing Listed Below
SCAL16486A Nalco Champion Scale Inhibitor Listed Below
Sand Sargent/Unimin Proppant Listed Below
Water Chief Oil & Gas Carrier/Base Fluid Listed Below
Crystallilne silica 14808-60-7 100 15.3177 22,152,900.0
Methanol 67-56-1 5 0.00001000 10
Ethoxylated (C10-16) alcohols 68002-97-1 35 0.00005000 71
Quaternary ammonium compound 68424-85-1 10 0.00229 3306
Thiourea 62-56-6 1 0.00001000 2
Ethylene glycol 107-21-1 30 0.00157 2269
Water 7732-18-5 40 0.00209 3026
Hydrochloric acid 7647-01-0 15 0.02463 35624
Oleic acid diethanolamide 93-83-4 2 0.00146 2108
Formaldehyde 50-00-0 1 0.00001000 2
Water 7732-18-5 100 84.417 122,086,000.0
Distillate, petroleum, hydrotreated, light 64742-47-8 20 0.01457 21076
Methanol 67-56-1 45 0.01029 14875
Water 7732-18-5 85 0.13958 201867
Water 7732-18-5 40 0.00914 13222
Glutaraldehyde 111-30-8 5 0.00114 1653
Diethylene glycol mono-n-butyl ether 112-34-5 60 0.00008000 122
Alcohols, C12-16, ethoxylated 68551-12-2 2 0.00146 2108
Ethanol, 2,2',2"-nitrilotris-,
tris(dihydrogen phosphate) (ester), sodium salt
68171-29-9 30 0.00157 2269
Water 7732-18-5 50 0.03643 52689
Acetophenone 98-86-2 1 0.00001000 2
Copolymer 2-Propenamide 79-06-1 20 0.01457 21076

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2019 CHIEF OIL & GAS LLC 5,238,121.27 293 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 CHIEF OIL & GAS LLC Drill Cuttings 1,297.50 Tons LANDFILL 301358
2018 CHIEF OIL & GAS LLC Synthetic Liner Materials 13.47 Tons LANDFILL 301358
2019 CHIEF OIL & GAS LLC Produced Fluid 360.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 CHIEF OIL & GAS LLC Drill Cuttings 5.68 Tons LANDFILL 301358
2019 CHIEF OIL & GAS LLC Synthetic Liner Materials 17.14 Tons LANDFILL 301358
2019 CHIEF OIL & GAS LLC Produced Fluid 33,763.15 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2737628 Primary Facility 2018-06-05 Preoperation Inspection No Violations Noted Site meets the requirements of § 3258. Inspection and production of materials, witnesses, depositions and rights of entry.

(a.1) Preoperation inspections.--The operator may not commence drilling activities until the department has conducted an inspection of the unconventional well site after the installation of erosion and sediment control measures. The department may conduct follow-up inspections of well sites and related activities to determine compliance with this chapter. All E&Scontrols in place. Site built to plan design. No violations noted.

Site preoperational approved on 6/5/2018.

2752969 Primary Facility 2018-07-18 Routine/Complete Inspection No Violations Noted Weather was 71° and sunny at time of inspection. There were no Chief representatives on location at time of inspection. Well is a spud conductor. A steel plate was welded over the top of the conductor casing at time of inspection. The mouse hole was also set and open. No violations noted at time of inspection.

For data sources see[8]