X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-015-23372

Well Details

Well ID: 37-015-23372
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Overton Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 154478
Farm/Lease Name: SGL-12 HARDY NORTH UNIT 1H
License Status:
Spud Date:
Permit Date: 2017-09-07
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.593722
Longitude: -76.660172

For data sources see[1][2][3]

Well History

Date Event
2017-09-07 New Permit Application
2018-03-02 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-08-09 2018-08-23 8,785 12,663,300 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Unihib G GeoSafe Acid Inhibitor Listed Below
Water Chief Oil & Gas Carrier/Base Fluid Listed Below
Sand Sargent/Unimin Proppant Listed Below
BIOC11139A Nalco Champion Biocide Listed Below
Unislick CST-LA Chemplex, Solvay Grp Friction Reducer Listed Below
Water 7732-18-5 85 0.15419 195379
Crystallilne silica 14808-60-7 100 16.3259 20,687,800.0
Thiourea 62-56-6 1 0.00001000 2
Distillate, petroleum, hydrotreated, light 64742-47-8 20 0.01356 17188
Hydrochloric acid 7647-01-0 15 0.02721 34479
Ethanol 64-17-5 5 0.00125 1583
Glutaraldehyde 111-30-8 5 0.00125 1583
Ethoxylated (C10-16) alcohols 68002-97-1 35 0.00005000 68
Ethanol, 2,2',2"-nitrilotris-,
tris(dihydrogen phosphate) (ester), sodium salt
68171-29-9 30 0.00161 2042
Diethylene glycol mono-n-butyl ether 112-34-5 60 0.00009000 117
Water 7732-18-5 40 0.00215 2722
Copolymer of 2-Propenamide 79-06-1 20 0.01356 17188
Methanol 67-56-1 5 0.00001000 10
Quaternary ammonium compound 68424-85-1 10 0.0025 3167
Oleic acid diethanolamide 93-83-4 2 0.00136 1719
Acetophenone 98-86-2 1 0.00001000 2
Water 7732-18-5 100 83.3943 105,675,000.0
Water 7732-18-5 80 0.01999 25335
Alcohols, C12-16, ethoxylated 68551-12-2 2 0.00136 1719
Formaldehyde 50-00-0 1 0.00001000 2
Water 7732-18-5 50 0.03391 42970
Ethylene glycol 107-21-1 30 0.00161 2042
Hydrochloric Acid PVS Acidizing Listed Below
SCAL16484A Nalco Champion Scale Inhibitor Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2018 CHIEF OIL & GAS LLC 809,504.55 65 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 3,961,753.66 363 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 CHIEF OIL & GAS LLC Produced Fluid 12,372.59 Bbl REUSE (AT WELL PAD)
2018 CHIEF OIL & GAS LLC Drill Cuttings 1,568.31 Tons LANDFILL 301358
2018 CHIEF OIL & GAS LLC Drilling Fluid Waste 347.21 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 CHIEF OIL & GAS LLC Produced Fluid 240.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 CHIEF OIL & GAS LLC Synthetic Liner Materials 21.49 Tons LANDFILL 301358
2019 CHIEF OIL & GAS LLC Produced Fluid 360.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 CHIEF OIL & GAS LLC Synthetic Liner Materials 32.54 Tons LANDFILL 301358
2019 CHIEF OIL & GAS LLC Drilling Fluid Waste 58.91 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2019 CHIEF OIL & GAS LLC Produced Fluid 11,199.73 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2676748 Primary Facility 2018-01-02 Preoperation Inspection No Violations Noted Site meets the requirements of 3258. Inspection and production of materials, witnesses, depositions and rights of entry.

(a.1) Preoperation inspections.--The operator may not commence drilling activities until the department has conducted an inspection of the unconventional well site after the installation of erosion and sediment control measures. The department may conduct follow-up inspections of well sites and related activities to determine compliance with this chapter. All E&Scontrols in place. Site built to plan design. No violations noted.

2701615 Primary Facility 2018-03-06 Drilling/Alteration No Violations Noted Two well cellars are being built by a development crew. All removed soil and gravel being placed within roll off containers. No other equipment on location.
2812025 Primary Facility 2018-12-06 Routine/Complete Inspection No Violations Noted Routine inspection conducted to assess overall site conditions. Two wells have recently been completed and are in flowback. Two frac tank batteries are on location within secondary containment. Most the pad surface and the surface within the secondary containments was ice-covered.

Two steel produced water tanks are present and in good condition. These sit within steel containment with spay-in liner in good condition. There was no water within this containment. Two GPUs are present within containment. The water within the containment was unfrozen and had a conductivity of less than 100 uS/cm.

Two sediment traps appear to be built as permitted and functioning as designed. Compost filter sock is deployed as the E&S plan calls for. Site is stable. No E&S issues noted.

No violations noted.

For data sources see[8]