X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-015-23362

Well Details

Well ID: 37-015-23362
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Leroy Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 154300
Farm/Lease Name: SGL-12 D EAST UNIT
License Status:
Spud Date:
Permit Date: 2017-07-18
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.590617
Longitude: -76.717683

For data sources see[1][2][3]

Well History

Date Event
2017-07-18 New Permit Application
2017-10-23 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2018-07-04 2018-07-10 8,223 7,131,940 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 BIOC11139A Nalco Champion Biocide Listed Below
SCAL16484A Nalco Champion Scale Inhibitor Listed Below
Sand Sargent/Unimin Proppant Listed Below
Oleic acid diethanolamide 93-83-4 2 0.00137 967
Thiourea 62-56-6 1 0.00001000 3
Alcohols, C12-16, ethoxylated 68551-12-2 2 0.00137 967
Water 7732-18-5 100 84.1548 59,516,000.0
Diethylene glycol mono-n-butyl ether 112-34-5 60 0.00021 150
Water 7732-18-5 40 0.00216 1530
Copolymer of 2-Propenamide 79-06-1 20 0.01368 9673
Water 7732-18-5 85 0.14051 99375
Ethylene glycol 107-21-1 30 0.00162 1147
Hydrochloric acid 7647-01-0 15 0.0248 17537
Ethanol, 2,2',2"-nitrilotris-,
tris(dihydrogen phosphate) (ester), sodium salt
68171-29-9 30 0.00162 1147
Crystallilne silica 14808-60-7 100 15.5807 11,019,000.0
Water 7732-18-5 80 0.02003 14166
Water 7732-18-5 50 0.03419 24182
Ethanol 64-17-5 5 0.00125 885
Methanol 67-56-1 5 0.00002000 13
Acetophenone 98-86-2 1 0.00001000 3
Quaternary ammonium compound 68424-85-1 10 0.0025 1771
Ethoxylated (C10-16) alcohols 68002-97-1 35 0.00012 88
Distillate, petroleum, hydrotreated, light 64742-47-8 20 0.01368 9673
Formaldehyde 50-00-0 1 0.00001000 3
Glutaraldehyde 111-30-8 5 0.00125 885
Unislick CST-LA Chemplex, Solvay Group Friction Reducer Listed Below
Acid Inhibitor, Unihib G GeoSafe Acid Inhibitor Listed Below
Water Chief Oil & Gas Carrier/Base Fluid Listed Below
Hydrochloric Acid PVS Acidizing Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2017 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 1,114,844.85 150 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 1,156,455.44 364 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2018 CHIEF OIL & GAS LLC Produced Fluid 9,595.14 Bbl REUSE (AT WELL PAD)
2018 CHIEF OIL & GAS LLC Produced Fluid 825.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 CHIEF OIL & GAS LLC Drill Cuttings 1,150.14 Tons LANDFILL 301358
2018 CHIEF OIL & GAS LLC Synthetic Liner Materials 10.56 Tons LANDFILL 301358
2019 CHIEF OIL & GAS LLC Produced Fluid 140.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2019 CHIEF OIL & GAS LLC Synthetic Liner Materials 2.36 Tons LANDFILL 301358
2019 CHIEF OIL & GAS LLC Produced Fluid 2,041.01 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2677376 Primary Facility 2018-01-03 Drilling/Alteration No Violations Noted No issues as of time of inspection.

Cold windy at time of inspection.

Conductor only.

2687398 Primary Facility 2018-01-23 Routine/Complete Inspection No Violations Noted I met Trey Villareal of Chief when I arrived onsite. H&P rig 513 on location at 2970' on the 3H well. Crews were cleaning ice and snow out of containment. I noted a section of berm near the mud logging trailer where the lock and key style berm was not run straight, but made a s-curve instead; in this area, there were several spots where the berm sections did not meet fully, and the liner was sagging between them. Near the cuttings backyard, I noted several spots where the liner on the berm was torn, likely from vehicular traffic in the area. I then met Aaron Stredny, Environmental Specialist for Chief, and pointed out the containment issues I had noted to him. Aaron took pictures of the aforementioned areas, and we spoke for a few minutes regarding solutions for this and other issues that we had noted on other locations. I informed Trey of my findings as well before I departed.
2734597 Primary Facility 2018-05-25 Routine/Complete Inspection No Violations Noted Six wells drilled. Site being staged for frack.
2747276 Primary Facility 2018-06-29 Drilling/Alteration No Violations Noted 4h and 1h wells being fracked.

No rig matting on location. Only polyurethane and felt liner.

No leaks detected. A small hole in the secondary containment was noted, but was marked by the operator for repair.

2747278 Primary Facility 2018-06-29 Drilling/Alteration No Violations Noted 4h and 1h wells being fracked.

No rig matting on location. Only polyurethane and felt liner.

No leaks detected. A small hole in the secondary containment was noted, but was marked by the operator for repair.

2762528 Primary Facility 2018-08-08 Incident- Response to Accident or Event No Violations Noted I spoke with Chief's Environmental Inspector, Aaron Stredny, who is guiding the cleanup of flowback that sprayed out of a gas buster trailer (photo 1). He said they started flowing back the six Marcellus Shale wells last Saturday (4 days ago), and that the gasbuster overflowed last night.

There was just enough liquid in the excavated area (photo 1) for me to get an electrical conductivity (EC) reading with an Oakton PCSTestr 35; it was 1.1 mS/cm. From puddles on the rest of the pad, the highest EC reading I got was 0.50 mS/cm. 78.56a is cited to the 015-23364 permit. The violation is considered immediately corrected. JLP

2813383 Primary Facility 2018-12-06 Routine/Complete Inspection No Violations Noted Routine inspection conducted to assess overall site conditions. Two frac tank batteries are on location within secondary containment. No problems with the containments were noted. Unlabeled containers are present near the well heads. The department recommends labeling these containers.

Six steel produced water tanks are present and in good condition. These sit within steel containment with spay-in liner in good condition. The water was frozen within this containment. Six GPUs are present within containment. The water within the containment was unfrozen and had a conductivity of less than 100 uS/cm.

Two sediment traps appear to be built as permitted and functioning as designed. Compost filter sock is deployed as the E&S plan calls for. Site is stable. No E&S issues noted.

No violations noted.

For data sources see[8]