37-015-23302

Well Details

Well ID: 37-015-23302
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Overton Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 151617
Farm/Lease Name: SGL-12 B SOUTH UNIT 1H
License Status:
Spud Date:
Permit Date: 2017-01-17
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.589289
Longitude: -76.684750

For data sources see[1][2][3]

Well History

Date Event
2017-01-17 New Permit Application
2017-03-22 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2017-09-18 2017-10-22 8,222 6,164,760 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Water Chief Oil & Gas Carrier/Base Fluid Listed Below
Unihib G GeoSafe Acid Inhibitor Listed Below
Water 7732-18-5 80 0.02032 12190
Water 7732-18-5 100 85.7347 5,144,920.0
Crystallilne silica 14808-60-7 100 14.0254 8,415,900.0
Methanol 67-56-1 5 0.00001000 4
Ethoxylated (C10-16) alcohols 68002-97-1 35 0.00004000 27
Thiourea 62-56-6 1 0.00001000 1
Ethanol 64-17-5 5 0.00127 762
Distillate, petroleum, hydrotreated, light 64742-47-8 30 0.01713 10281
Alcohols, (C10-16), ethoxylated 68002-97-1 5 0.00286 1714
Diethylene glycol mono-n-butyl ether 112-34-5 60 0.00008000 46
Ethylene glycol 107-21-1 30 0.00162 974
Ammonium acetate 631-61-8 13 0.00742 4455
Acetophenone 98-86-2 1 0.00001000 1
Hydrochloric acid 7647-01-0 15 0.02277 13665
Formaldehyde 50-00-0 1 0.00001000 1
Ethanol, 2,2',2"-nitrilotris-,
tris(dihydrogen phosphate) (ester), sodium salt
68171-29-9 30 0.00162 974
Quaternary ammonium compound 68424-85-1 10 0.00254 1524
Alcohols, C12-16, ethoxylated 68551-12-2 5 0.00286 1714
Glutaraldehyde 111-30-8 5 0.00127 762
Alcohols, C12-14, ethoxylated 68439-50-9 5 0.00286 1714
Water 7732-18-5 40 0.00217 1299
Water 7732-18-5 85 0.12905 77434
Sand Sargent/Unimin Proppant Listed Below
BIOC 11139A Nalco Champion Biocide Listed Below
Hydrochloric Acid PVS Acidizing Listed Below
Unislick E CESI Chemical Friction Reducer Listed Below
SCAL 16486A Nalco Champion Scale Inhibitor Listed Below

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2017 CHIEF OIL & GAS LLC 668,113.05 87 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 1,962,197.83 339 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 1,137,088.41 363 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2017 CHIEF OIL & GAS LLC Other Oil & Gas Wastes 3.30 Tons LANDFILL 100280
2017 CHIEF OIL & GAS LLC Unused Fracturing Fluid Waste 90.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2017 CHIEF OIL & GAS LLC Produced Fluid 4,568.50 Bbl REUSE (AT WELL PAD)
2017 CHIEF OIL & GAS LLC Soil Contaminated by Oil 4.45 Tons LANDFILL 301358
2017 CHIEF OIL & GAS LLC Soil Contaminated by Oil & Gas Related Spills 4.45 Tons LANDFILL 301358
2017 CHIEF OIL & GAS LLC Produced Fluid 180.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 CHIEF OIL & GAS LLC Soil Contaminated by Oil 30.27 Tons LANDFILL 301358
2018 CHIEF OIL & GAS LLC Produced Fluid 4,153.63 Bbl REUSE (AT WELL PAD)
2018 CHIEF OIL & GAS LLC Drilling Fluid Waste 108.95 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NC010
2018 CHIEF OIL & GAS LLC Soil Contaminated by Oil & Gas Related Spills 30.27 Tons LANDFILL 301358
2019 CHIEF OIL & GAS LLC Produced Fluid 2,308.89 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2576175 Primary Facility 2017-03-28 Routine/Complete Inspection No Violations Noted Four well cellars and conductors being drilled at time by Halliburton. Drill cuttings are being placed within two roll off containers. Site stable. No violations noted at this time.
2584123 Primary Facility 2017-04-18 Routine/Complete Inspection No Violations Noted The rig is being assembled at this time. Secondary containment not fully completed. No e&s concerns. No violations noted.
2597431 Primary Facility 2017-05-24 Routine/Complete Inspection No Violations Noted I arrived onsite @ 12:05 hrs. and met Ray Miller and Brandon Jessen of Chief. H& P Flex rig 513 on location drilling the South 1H well; crew was nippling up the well for a BOP test when I arrived. Sitewide liner was covered by rig mats, berms appeared to be in good condition. Some rusty colored water had collected in a corner of the containment near the chemical storage area where no rig mats were down; I recommended it be vacced up. Generator sets are being run with natural gas brought in from pipeline. I departed @ 12:50 hrs.
2608497 Primary Facility 2017-06-15 Follow-up Inspection No Violations Noted Arrived @ 12:40. Weather:cloudy, cooler. HP 513 was onsite drilling the SGL 12 B North Unit 1H production hole at 11, 486 at the time of my inspection. There were also three recently TD’ed wells accessible in light of the rig operations. These wells were:

SGL 12 B N Unit 3H SGL 12 B S Unit 1H SGL 12 B S Unit 3H. Accompanying me was Jon Hafer (Chief) who brought with him a fresh water truck and a vac truck. Met with Company Man Trey Villeneuve. The purpose of this inspection was to fill the cellars of the TD’ed wells, to determine whether there was methane outside of surface casing. Water was added to each cellar to a level just above the wellhead flutes, where the cement between the conductor and surface casing was exposed. Following the addition of the water, we waited approximately 20 minutes and searched for any signs of bubbling. No signs of bubbling were seen in the cellars of the 3 wells listed above. Following these observations, the vac truck removed the water from the cellars. The result of

2626310 Primary Facility 2017-08-16 Routine/Complete Inspection No Violations Noted Arrived @ 9:40. Weather: sunny. There were 4 wells on site, all with frac heads.

SGL12 B S Unit 3H – cellar empty, cement bottom visible. Only 9-5/8” x 5-1/2” annulus vent open to polytank.13-3/8” x 9-5/8” annulus appeared to be open, the welded cap across the annulus appeared to be partially off. SGL 12 B N Unit 3H – GE RSH2 wellhead, gravel in cellar with water. Water level approximately 2” above the flutes, no bubbling. 5-1/2” 2000 psi (0-10,000 psi analog). 13-3/8” x 9-5/8” and 9-5/8” x 5-1/2” annuli plumbed to a polytank shared with the SGL12 B S Unit 3. 80% methane/volume at polytank opening (Altair 5X gas meter calibrated on 8-14-17). SGL 12 B S Unit 1H – GE RSH2 wellhead. Water and gravel in cellar, can’t see flutes, no bubbling. 5-1/2”:2000 psi (0-10,000 psi analog). 13-3/8” x9-5/8” and 9-5/8” x 5-1/2” annuli plumbed to polytank . SGL 12 B N Unit 1H – GE RSH2 wellhead. Flutes visible water and gravel in cellar, no bubbles. 5-1/2”; 2000 psi (0-10,000 psi, analog). Both annuli plumbed to polytank

2656926 Primary Facility 2017-10-31 Routine/Complete Inspection No Violations Noted Site was quiet when I arrived, with only 2 vac trucks and their operators on location. 4 temporary sand separators were set up on containment near the well heads. The secondary containments for the Baker tanks were in excellent condition, and the sitewide liner also appeared to be in good shape. Some foam berms had been removed from the sitewide liner in a traffic area, but no fluid was present on or off containment that showed elevated conductance. I recommend that these berms be left in place as much as possible.
2747182 Primary Facility 2018-06-29 Routine/Complete Inspection No Violations Noted Fours wells staged for production phase. Four each water separators. Dump lines wrapped in insulating blanket. No leaks detected from production equipment. Equipment being stored on location for SGL 12 D frac and operations on the Hardy pad. On equipment stored on secondary containment. No violations noted.
2813060 Primary Facility 2018-12-06 Routine/Complete Inspection No Violations Noted Routine inspection conducted to assess overall site conditions. Four wells are staged for production. The well tag for the South 1H well has fallen off and is sitting next to the well head. An unlabeled container is present near the well heads. The department recommends labeling the container.

Four steel produced water tanks are present and in good condition. These sit within steel containment with spay-in liner in good condition. The water within the containment was frozen at the time of inspection. Four GPUs are present within containment. The water within the containment was unfrozen and had a conductivity of less than 100 uS/cm.

Two infiltration areas appear to be built as permitted and functioning as designed. Compost filter sock is deployed as the E&S plan calls for. The slope near the northwest corner of the pad is rocked. There is a series of rills in the rock here. Some of the rock appears to have slid down this slope as well. The department recommends inspecting this slope frequently to prevent

For data sources see[8]