37-015-22076

Well Details

Well ID: 37-015-22076
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Leroy Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 146000
Farm/Lease Name: YODER UNIT 1H
License Status:
Spud Date:
Permit Date: 2011-12-20
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.679172
Longitude: -76.675161

For data sources see[1][2][3]

Well History

Date Event
2011-12-20 New Permit Application
2012-04-12 Performed Spud Operation

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2012-10-11 2012-10-11 7,138 4,751,628
2 2012-07-02 2012-07-02 7,138 1,536,948

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Fresh Water Base Fluid Fresh Water 100.00 82.08
(J609) Schlumberge
Friction Reducer
Ammonium Sulfate

7783-20-2 10.0 - 30.0 r
0.09
Biocide - Bactron K 139 Champion Technologies Biocide Glutaraldehyde 111-30-8 0.03
Ethanol 64-17-5
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1
benzyl-C12-16 alkyldimethyl,chlorides
Sand (Proppant) Schlumberger Propping Agent
Quartz 14808-60-7 99.90 17.79
(J609) Schlumberge
Friction Reducer
Ammonium Sulfate

7783-20-2 10.0 - 30.0 r
Champion Technologies Biocide
Scale Inhibitor - Gyptron T-390 Champion Technologies Scale Inhibitor Methanol 67-56-1 0.00900000
2 Scale Inhibitor - Gyptron T-390 Champion Technologies Scale Inhibitor
Methanol 67-56-1 0.01
Hydrochloric Acid 15 Frac Tech Services (FTS) Acid Water 7732-18-5
Hydrochloric acid 7647-01-0 0.39
Fresh Water Base Fluid Fresh Water 100.00 84.00
FRW-600 Frac Tech Services (FTS) Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 0.10
Sand (Proppant) Frac Tech Services (FTS) Propping Agent
Quartz 14808-60-7 99.90 15.43
Biocide - Bactron K 139 Champion Technologies Biocide
Ethanol 64-17-5
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1
benzyl-C12-16 alkyldimethyl,chlorides
Glutaraldehyde 111-30-8 0.06

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 1,670,494.00 254 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 1,469,824.00 365 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 802,275.51 340 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 731,348.76 365 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 481,176.21 271 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 605,645.15 363 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 398,532.63 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 CHIEF OIL & GAS LLC Drill Cuttings 1,556.04 Tons LANDFILL 301358
2012 CHIEF OIL & GAS LLC Fracing Fluid Waste 2,015.00 Bbl REUSE OTHER THAN ROAD SPREADING
2012 CHIEF OIL & GAS LLC Drill Cuttings 15.57 Tons LANDFILL 100933
2013 CHIEF OIL & GAS LLC Produced Fluid 114.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123SW018
2013 CHIEF OIL & GAS LLC Produced Fluid 10,067.50 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHIEF OIL & GAS LLC Produced Fluid 3,082.80 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHIEF OIL & GAS LLC Fracing Fluid Waste 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR119
2015 CHIEF OIL & GAS LLC Produced Fluid 406.12 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Produced Fluid 1,005.41 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Produced Fluid 471.93 Bbl REUSE (AT WELL PAD)
2017 CHIEF OIL & GAS LLC Produced Fluid 18.46 Bbl REUSE OTHER THAN ROAD SPREADING
2018 CHIEF OIL & GAS LLC Soil Contaminated by Oil 28.50 Tons LANDFILL 301358
2018 CHIEF OIL & GAS LLC Soil Contaminated by Oil & Gas Related Spills 28.50 Tons LANDFILL 301358
2018 CHIEF OIL & GAS LLC Produced Fluid 1,007.20 Bbl REUSE (AT WELL PAD)
2019 CHIEF OIL & GAS LLC Produced Fluid 161.11 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2041629 Primary Facility 2012-02-08 Routine/Complete Inspection No Violations Noted
2062925 Primary Facility 2012-04-26 Incident- Response to Accident or Event Violation(s) Noted
2072760 Primary Facility 2012-05-20 Drilling/Alteration No Violations Noted
2072762 Primary Facility 2012-05-23 Drilling/Alteration No Violations Noted
2081137 Primary Facility 2012-07-05 Incident- Response to Accident or Event Violation(s) Noted
2086563 Primary Facility 2012-07-26 Routine/Complete Inspection Outstanding Violations - No Viols Req'd
2089730 Primary Facility 2012-08-07 Routine/Complete Inspection Outstanding Violations - No Viols Req'd
2097401 Primary Facility 2012-09-05 Routine/Complete Inspection No Violations Noted
2100730 Primary Facility 2012-09-18 Routine/Complete Inspection No Violations Noted
2120407 Primary Facility 2012-10-16 Incident- Response to Accident or Event Viol(s) Noted & Immediately Corrected
2341171 Primary Facility 2015-01-30 Routine/Partial Inspection No Violations Noted
2556407 Primary Facility 2017-01-30 Routine/Complete Inspection No Violations Noted One well in production phase. One water separator within steel containment. No leaks detected from production equipment at this time. Silt sock on top of tarp material surrounding quarter of pad. The DEP will request inspection documents related to the corroded production tank. This request is in accordance with PA code Chapter 25, 78a.57. Control, Storage and disposal of production fluids.

" (i) Tanks storing brine or other fluids produced during operation of the well shall be inspected by the operator at least once per calendar month and documented. Deficiencies noted during the inspection shall be addressed and remedied. When substantial modifications are necessary to correct deficiencies, they shall be made in accordance with manufacturer's specifications and applicable engineering design criteria. Any deficiencies identified during the inspection shall be reported to the Department electronically through its web site within 3 days of the inspection and remedied prior to continued use of the tank. Insp

2556870 Primary Facility 2017-01-31 Routine/Complete Inspection No Violations Noted One well in production phase. One water separator within steel containment. No leaks detected from production equipment at this time. Silt sock on top of tarp material surrounding quarter of pad. The DEP will request inspection documents related to the corroded production tank. This request is in accordance with PA code Chapter 25, 78a.57. Control, Storage and disposal of production fluids. " (i) Tanks storing brine or other fluids produced during operation of the well shall be inspected by the operator at least once per calendar month and documented. Deficiencies noted during the inspection shall be addressed and remedied. When substantial modifications are necessary to correct deficiencies, they shall be made in accordance with manufacturera^€TMs specifications and applicable engineering design criteria. Any deficiencies identified during the inspection shall be reported to the Department electronically through its web site within 3 days of the inspection and remedied prior to continued use of the tank. In
2581364 Primary Facility 2017-04-11 Routine/Complete Inspection No Violations Noted One well in production phase. One separator within plastic lined containment. No leaks detected from production equipment. Production tank replaced. Site stable. No violations noted.
2594932 Primary Facility 2017-05-16 Routine/Complete Inspection No Violations Noted
2616475 Primary Facility 2017-07-05 Routine/Complete Inspection No Violations Noted Drilling of the 3H well will be complete tonight. The drill of the 2H will begin shortly thereafter. All substances within secondary containment. No leaks or spills detected. No violations. Precision Rig 569 on site.
2649675 Primary Facility 2017-10-18 Incident- Response to Accident or Event Viol(s) Noted & Immediately Corrected I arrived at the site in response to a spill notification received Tuesday 10/17 at 16:00 hrs. Chief reported that approximately 1 barrel of fracwater/brine with friction reducer was spilled to the pad when a valve cover failed on the missile. I met Justin Myers and Chris Marsh when I was on-site. We looked at the area where the spill had occurred, and they informed me that Kellon Balum of Chief arrived soon after the spill and stopped the frac. They observed fluid coming out from under the liner, so Kellon had the equipment removed from the area, the containment pulled back, and immediately began removing the affected soil. Chris estimated that 2.5-3 cubic yards of soil had been removed, and pointed out the pile of soil on containment. Kellon assisted the excavation by screening the soil for TDS and had the excavation continue until the soil reached background levels (100-200 ppm). Once he determined that the release had been removed, he noted several holes in the liner that had been pulled back. Th
2659876 Primary Facility 2017-11-09 Routine/Complete Inspection No Violations Noted I met Floyd Roberts of Chief when I arrived. Workover rig on location to drill out plugs. Some small puddles were present in the area of the spill reported on 10/17; conductivity of these puddles was low (from .098 to .9 mS/cm). Some of the foam berms had been removed in antraffic area on the containment; although I didn't note any chemicals or waste in this area, I recommended to Floyd that he assess whether or not the berms should be put back in place.
2676434 Primary Facility 2018-01-02 Incident- Response to Accident or Event Pending Well is shut in due to a fire in one of the GPU units on 12/29/2017.

The GPU for the 2H and 3H wells were removed from the well pad as well as containment, to allow access to further investigate the fire.

All wells on the pad were temp shut in at time of inspection.

All annulus vents are vented to polly tank on location.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2062925 637971 04/26/2012 2012-04-26 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety Diesel Fuel spill from Rig generator.
2062925 638295 04/26/2012 2012-04-26 CSL402POTPOL - There is a potential for polluting substance(s) reaching Waters of the Commonwealth and may require a permit Environmental Health & Safety
2062925 638296 04/26/2012 2012-04-26 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety
2081137 643316 07/05/2012 2012-07-05 401 CSL - Discharge of pollultional material to waters of Commonwealth. Environmental Health & Safety 4700 gallons of HCL spilled.
2081137 643317 07/05/2012 2012-07-05 301CSL - Stream discharge of IW, includes drill cuttings, oil, brine and/or silt Environmental Health & Safety 4700 gallons of HCL spilled.
2081137 643318 07/05/2012 2012-07-05 SWMA301 - Failure to properly store, transport, process or dispose of a residual waste. Environmental Health & Safety 4700 gallons of HCL spilled.
2081137 643319 07/05/2012 2012-07-05 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety 4700 gallons of HCL spilled.
2081137 643320 07/05/2012 2012-07-05 307CSL - Discharge of industrial waste to waters of Commonwealth without a permit. Environmental Health & Safety 4700 gallons of HCL spilled.
2120407 655013 10/16/2012 2012-10-16 78.54* - Failure to properly control or dispose of industrial or residual waste to prevent pollution of the waters of the Commonwealth. Environmental Health & Safety Spill of 420 gallons of re-use water.
2120407 655014 10/16/2012 2012-10-16 402CSL - Failure to adopt pollution prevention measures required or prescribed by DEP by handling materials that create a danger of pollution. Environmental Health & Safety Spill of 420 gallons of reuse water.
2649675 799550 2017-10-18 2017-10-18 78A57(A) Environmental Health & Safety Release of pollutional substance to pad surface
2649675 799551 2017-10-18 2017-10-18 SWMA 301 Environmental Health & Safety Release of pollutional substance to pad surface
2649675 799552 2017-10-18 2017-10-18 CSL 402(b) Environmental Health & Safety Release of pollutional substance to pad surface

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
637971 283344 NOV - Notice of Violation Comply/Closed 2014-11-12
638295 283344 NOV - Notice of Violation Comply/Closed 2014-11-12
638296 283344 NOV - Notice of Violation Comply/Closed 2014-11-12
643316 285633 NOV - Notice of Violation Comply/Closed 2015-01-30
643317 285633 NOV - Notice of Violation Comply/Closed 2015-01-30
643318 285633 NOV - Notice of Violation Comply/Closed 2015-01-30
643319 285633 NOV - Notice of Violation Comply/Closed 2015-01-30
643320 285633 NOV - Notice of Violation Comply/Closed 2015-01-30

For data sources see[8]