X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-015-21440

Well Details

Well ID: 37-015-21440
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Burlington Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 147968
Farm/Lease Name: CLEAR SPRING DAIRY UNIT 4H
License Status:
Spud Date:
Permit Date: 2011-01-10
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 41.763525
Longitude: -76.534008

For data sources see[1][2][3]

Well History

Date Event
2011-01-10 New Permit Application
2011-04-07 Performed Spud Operation
2011-06-11 Perforation
2011-09-14 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2011-07-01 2011-07-01 7,000 4,787,790

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Alpha 1427 BJ Services Company Biocide Ethanol 64-17-5
Quaternary ammonium compounds,
benzyl-C12-16-alkyldimethyl, chlorides
68424-85-1
Didecyl dimethyl ammonium chloride 7173-51-5
Water 7732-18-5
Glutaraldehyde 111-30-8 0.02
Water Base Fluid Water 100.00 86.76
Scaletrol 720 BJ Services Company Scale Inhibitor Ethylene glycol 107-21-1 0.04
Diethylene glycol 111-46-6
FRW-18 BJ Services Company Friction Reducer Distillates, petroleum, hydrotreated light 64742-47-8 0.08
Techni-Hib 604 BJ Services Company Oxygen Scavenger
Ammonium bisulfite 10192-30-0 75.00 0.01
Water 7732-18-5 5.00
Sand (Proppant) BJ Services Company Propping Agent
Quartz 14808-60-7 99.90 13.06

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 CHIEF OIL & GAS LLC 592,904.00 149 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 1,226,971.98 366 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 1,025,398.00 365 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 811,934.00 349 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 336,841.72 231 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 357,224.47 249 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 424,831.48 365 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 411,295.12 365 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 251,018.06 362 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 8,925.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CHIEF OIL & GAS LLC Produced Fluid 70.00 Bbl REUSE OTHER THAN ROAD SPREADING
2011 CHIEF OIL & GAS LLC Drill Cuttings 1,292.60 Tons LANDFILL 301626
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 595.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2012 CHIEF OIL & GAS LLC Produced Fluid 2,298.90 Bbl REUSE OTHER THAN ROAD SPREADING
2013 CHIEF OIL & GAS LLC Produced Fluid 1,291.60 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHIEF OIL & GAS LLC Produced Fluid 327.00 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Produced Fluid 15.17 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Produced Fluid 99.38 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Produced Fluid 21.01 Bbl STORAGE PENDING DISPOSAL OR REUSE
2017 CHIEF OIL & GAS LLC Produced Fluid 40.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123
2018 CHIEF OIL & GAS LLC Produced Fluid 30.40 Bbl REUSE (AT WELL PAD)

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1986628 Primary Facility 2011-07-06 Follow-up Inspection No Violations Noted
2562755 Primary Facility 2017-02-17 Routine/Complete Inspection No Violations Noted Three wells introduction phase. Three separators within containment. No leaks detected from production tank. No wellsite access gate for security purposes. No violations noted at this time.
2683036 Primary Facility 2018-01-17 Routine/Complete Inspection No Violations Noted Three wells in production phase. Three water separators. Separators within containment. No leaks detected from production equipment. No violations noted.

For data sources see[8]

References