37-015-20668

Well Details

Well ID: 37-015-20668
Loading map...
Country: United States
State: Pennsylvania
County: Bradford
Municipality: Canton Township
Operator Name: CHIEF OIL & GAS LLC
Well Pad ID: 146453
Farm/Lease Name: SECHRIST UNIT 1H
License Status: INACTIVE
Spud Date:
Permit Date: 2010-03-11
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: No
Latitude: 41.658389
Longitude: -76.808778

For data sources see[1][2][3]

Well History

Date Event
2010-03-11 New Permit Application
2010-06-22 Performed Spud Operation
2010-08-26 NEWLY DRILLED
2010-11-09 Perforation

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2011 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2012 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0
2013 CHIEF OIL & GAS LLC 4,188.00 61 0.00 0 0.00 0
2014 CHIEF OIL & GAS LLC 9,287.00 323 0.00 0 0.00 0
2015 CHIEF OIL & GAS LLC 2,365.85 258 0.00 0 0.00 0
2016 CHIEF OIL & GAS LLC 5,223.21 41 0.00 0 0.00 0
2017 CHIEF OIL & GAS LLC 1,051.14 7 0.00 0 0.00 0
2018 CHIEF OIL & GAS LLC 1,320.28 4 0.00 0 0.00 0
2019 CHIEF OIL & GAS LLC 0.00 0 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 CHIEF OIL & GAS LLC Drilling Fluid Waste 1,726.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR119
2010 CHIEF OIL & GAS LLC Drilling Fluid Waste 2,442.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0027057
2010 CHIEF OIL & GAS LLC Fracing Fluid Waste 55.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0027057
2010 CHIEF OIL & GAS LLC Fracing Fluid Waste 4,304.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2011 CHIEF OIL & GAS LLC Fracing Fluid Waste 487.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0008451
2013 CHIEF OIL & GAS LLC Produced Fluid 581.00 Bbl REUSE OTHER THAN ROAD SPREADING
2014 CHIEF OIL & GAS LLC Produced Fluid 1,819.87 Bbl REUSE OTHER THAN ROAD SPREADING
2015 CHIEF OIL & GAS LLC Produced Fluid 318.63 Bbl REUSE OTHER THAN ROAD SPREADING
2016 CHIEF OIL & GAS LLC Produced Fluid 483.11 Bbl REUSE OTHER THAN ROAD SPREADING
2017 CHIEF OIL & GAS LLC Produced Fluid 46.67 Bbl STORAGE PENDING DISPOSAL OR REUSE
2017 CHIEF OIL & GAS LLC Produced Fluid 60.12 Bbl REUSE (AT WELL PAD)

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1889236 Primary Facility 2010-06-01 Routine/Complete Inspection No Violations Noted
1897008 Primary Facility 2010-07-07 Routine/Partial Inspection No Violations Noted
2100713 Primary Facility 2012-09-13 Administrative/File Review Viol(s) Noted & Immediately Corrected
2144071 Primary Facility 2013-02-28 Routine/Complete Inspection No Violations Noted
2203926 Primary Facility 2013-09-12 Routine/Complete Inspection Violation(s) Noted
2228855 Primary Facility 2013-11-05 Routine/Complete Inspection No Violations Noted
2469473 Primary Facility 2016-03-30 Site Restoration No Violations Noted Restoration Report approved.
2560135 Primary Facility 2017-02-09 Routine/Complete Inspection No Violations Noted One well in production phase. One separator within plastic containment. Site stable. Inspection records will be requested for corroded production storage tank. No violations noted at this time.
2581280 Primary Facility 2017-04-11 Routine/Complete Inspection No Violations Noted One well in production phase. One separator within plastic containment. The steel production tank was removed and replaced. Site stable. No violations noted at this time.
2679869 Primary Facility 2018-01-09 Routine/Complete Inspection No Violations Noted Inspection to assess overall site conditions. No violations cotes.
2789269 Primary Facility 2018-10-16 Routine/Complete Inspection No Violations Noted Weather was 52° and sunny at time of inspection. There were no chief representatives on location at time of inspection. Well had digital pressure monitoring equipment on the production tubing and the production casing. Well had a 0-3k psi gauge on the production tubing attached above the swab valve that read 2000 psi. There was a 0-5k psi analog pressure gauge attached to the production casing via a wing valve that also read 2000 psi at time of inspection. The well emergency shut in device(ESD) appeared to be actuated at time of inspection. Spoke with Jon Hafer over the phone and it was determined that the ESD was not triggered in an emergency situation. This was just how the well was closed in due to poor production. There was a 0-5k psi gauge attached to the pay line past the ESD that read 0 psi at time of inspection. There was one annulus vent plumbed to surface that was run into a poly vent tank. The poly vent tank had a small amount of water in the bottom of it however 0% Combustible gas was detected at
2840313 Primary Facility 2019-02-13 Routine/Complete Inspection No Violations Noted Routine inspection conducted to assess overall site conditions. Site was snow-covered at the time of inspection. One well is staged for production and has a well tag. One GPU is present within containment and is in good condition. A cap is coming off of the back of the GPU (see photo #3). One steel produced water tank is present and in good condition. The secondary containment around the produced water tank is steel with plastic lining and it is in good condition. No ESCGP was ever issued for this site. The pad size has been reduced.

No violations noted.

Violations Commited

Inspection ID Violation ID Violation Date Date Resolved Violation Code Violation Type Violation Comments
2100713 649473 09/13/2012 2012-09-13 78.122 - Drillers Log not on site Administrative overdue well record report
2203926 677834 09/12/2013 2013-09-12 206C - Failure to restore well site within nine months after completion of drilling, failure to remove all pits, drilling supplies and equipment not needed for production. Administrative 2012 OGA Section 3216c cited

Penalties Applied

Violation ID Penalty ID Penalty Code Penalty Status Penalty Date Enforcement Date Penalty Amount Amount Collected
649473 288645 CACP - Consent Assessment of Civil Penalty Comply/Closed 2012-09-13 2012-09-13 $500.00 $500.00
677834 302161 NOV - Notice of Violation Administrative Close Out 2014-01-15

For data sources see[7]