Well ID: 37-005-31228 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.814731,"lon":-79.614192,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: West Franklin Township | |
Operator Name: EQT PROD CO | |
Well Pad ID: 152319 | |
Farm/Lease Name: CENTURY HILL 593543 | |
License Status: Plugged and Abandoned | |
Spud Date: | |
Permit Date: 2015-03-10 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Horizontal Well | |
Conservation: No | |
Latitude: 40.814731 | |
Longitude: -79.614192 |
Date | Event |
---|---|
2015-03-10 | New Permit Application |
2015-03-23 | Performed Spud Operation |
2016-05-18 | New Permit Application |
2018-05-04 | Begin Plugging |
2018-05-07 | Finished Plugging |
2018-08-28 | Fully Plugged |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2015 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2016 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2017 | EQT PROD CO | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
For data sources see[5]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2015 | EQT PROD CO | Drilling Fluid Waste | 690.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2015 | EQT PROD CO | Drill Cuttings | 254.00 Tons | LANDFILL | 100585 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 80.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123SW019 |
2018 | EQT PROD CO | Other Oil & Gas Wastes | 65.00 Bbl | RESIDUAL WASTE PROCESSING FACILITY | WMGR123NW009 |
For data sources see[6]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
2354311 | Primary Facility | 2015-03-24 | Preoperation Inspection | Viol(s) Noted & Immediately Corrected | Drilling had commenced, but was not ongoing at the time of the inspection. Site and access road erosion controls had been implemented as outlined in the E&S plan located onsite. All cut and fill slopes had been temporarily stabilized and there was no observed accelerated erosion or sedimentation in relation to the site or access road. It was noted that drilling had commenced prior to completion of a pre-operational inspection. |
2354603 | Primary Facility | 2015-03-24 | Drilling/Alteration | No Violations Noted | Waiting on rig to commence tophole drilling. |
2357506 | Primary Facility | 2015-04-02 | Routine/Complete Inspection | No Violations Noted | Drilling had commenced but was not ongoing at the time of the inspection. All cut and fill slopes had been temporarily stabilized with seed and mulch. All site and access road controls had been properly installed and there was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2357597 | Primary Facility | 2015-03-30 | Drilling/Alteration | No Violations Noted | Moving out Alpha Hunter rig#8 equipment at time of inspection. Waiting on rig to continue tophole drilling. |
2377406 | Primary Facility | 2015-06-09 | Routine/Complete Inspection | No Violations Noted | Drilling had commenced but was not ongoing at the time of the inspection. All cut and fill slopes had been temporarily stabilized, although these areas were minimal due to the cultivated agricultural fields around the well pad. All site and access road controls had been properly installed and there was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2377836 | Primary Facility | 2015-06-08 | Drilling/Alteration | No Violations Noted | Waiting on rig to continue tophole drilling. |
2406059 | Primary Facility | 2015-09-09 | Routine/Complete Inspection | No Violations Noted | Drilling had commenced but was not ongoing at the time of the inspection. All cut and fill slopes had been temporarily stabilized, although these areas were minimal due to the cultivated agricultural fields around the well pad. All site and access road erosion controls had been properly installed and there was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2484830 | Primary Facility | 2016-05-17 | Routine/Complete Inspection | No Violations Noted | Drilling was not ongoing at the time of the inspection. All cut and fill slopes had been temporarily stabilized, although these areas were minimal due to the cultivated agricultural fields around the well pad. All site and access road erosion controls had been properly installed and there was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2566735 | Primary Facility | 2017-03-02 | Routine/Complete Inspection | No Violations Noted | There was no activity ongoing at the site at the time of the inspection. There was no observed accelerated erosion or sedimentation in relation to the site or access road. The site had been effectively stabilized and agricultural fields were noted adjacent to the well site. |
2726910 | Primary Facility | 2018-05-07 | Plugging(Includes Plugged/Mined Through) | No Violations Noted | This well was only drilled to 648' and was not finished. The plugging rig cemented the well solid from the TD of 648' to surface. A monument plate with the required well information was permanently affixed to the top of the cemented casing and buried 5' below the surface. All equipment on site looked ok. |
2748409 | Primary Facility | 2018-07-03 | Routine/Complete Inspection | No Violations Noted | At time of inspection, both wells on this pad have been plugged. Plugging was completed for Well 593543 on 5/7/2018. |
2824337 | Primary Facility | 2019-01-09 | Administrative/File Review | No Violations Noted | Admin inspection conducted in response to restoration report received by the Department on 10/01/2018.
This well is an unconventional well and was reported to be plugged on 5/7/2018. Per current regulations, the post-plugging restoration report shall be made electronically on forms provided by the Department through the Department’s web site. As this restoration report was incorrectly submitted, it is not being approved. No violations are being noted at this time as the operator is within the regulatory requirements for submission of the post-plugging restoration report. |
2836029 | Primary Facility | 2019-02-04 | Site Restoration | No Violations Noted | On 2/4/19 at 1109 hrs., I conducted a restoration inspection of EQT Production Co.'s Century Hill well site in response to a Post-Plugging Restoration Report submitted for well permit 005-31228 by EQT on 1/21/19 (attached). The well site is located in West Franklin Twp., Armstrong County. A review of previous Department inspections show that a paper submittal of this report was initially rejected due to the fact that the operator is required to submit the report electronically. Previous Department inspections also reflect that the ESCGP associated with the site has been terminated. Upon inspection, it was confirmed that the well site has been restored and is permanently stabilized according to the as-built schematic (attached) which was also submitted with the restoration report. The restoration report is hereby approved; however the operator should remove the well permit signs, Act 9 site ID sign, and permit mailbox from the entrance to the location. There are no violations noted for this inspection. |
Inspection ID | Violation ID | Violation Date | Date Resolved | Violation Code | Violation Type | Violation Comments |
---|---|---|---|---|---|---|
2354311 | 718324 | 03/24/2015 | 2015-03-24 | OGA3258(A.1) - Drilling commenced without preoperation inspection. | Environmental Health & Safety |
Violation ID | Penalty ID | Penalty Code | Penalty Status | Penalty Date | Enforcement Date | Penalty Amount | Amount Collected |
---|---|---|---|---|---|---|---|
718324 | 321183 | NOV - Notice of Violation | Comply/Closed | 2015-03-24 |
For data sources see[7]