X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-005-31202

Well Details

Well ID: 37-005-31202
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: South Buffalo Township
Operator Name: XTO ENERGY INC
Well Pad ID: 151111
Farm/Lease Name: ALEXANDER LINDSAY UNIT
License Status: Active
Spud Date: 2014-08-05
Permit Date: 2014-05-06
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: No
Latitude: 40.738939
Longitude: -79.683653

For data sources see[1][2][3]

Well History

Date Event
2014-05-06 New Permit Application
2014-08-04 Performed Spud Operation
2014-09-13 Drilling Completion
2015-03-19 Perforation
2015-03-20 Performed Stage 1 of Stimulation
2015-03-21 Performed Stage 2 of Stimulation
2015-03-21 Performed Stage 3 of Stimulation
2015-03-23 Performed Stage 4 of Stimulation
2015-03-25 Performed Stage 5 of Stimulation
2015-03-26 Performed Stage 6 of Stimulation
2015-03-27 Performed Stage 7 of Stimulation
2015-03-27 Performed Stage 8 of Stimulation
2015-03-28 Performed Stage 9 of Stimulation
2015-03-30 Performed Stage 10 of Stimulation
2015-03-30 Performed Stage 11 of Stimulation
2015-04-01 Performed Stage 12 of Stimulation
2015-04-03 Performed Stage 13 of Stimulation
2015-04-06 Performed Stage 14 of Stimulation
2015-04-07 Performed Stage 15 of Stimulation
2015-04-08 Performed Stage 16 of Stimulation
2015-04-09 Performed Stage 17 of Stimulation
2015-04-10 Performed Stage 18 of Stimulation
2015-04-11 Performed Stage 19 of Stimulation
2015-04-13 Performed Stage 20 of Stimulation
2016-06-21 Deviated

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2015-03-18 2015-04-13 6,434 6,876,450 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Biocide, EC6116A Nalco Biocide Polyethylene Glycol 25322-68-3 60 0.00741475 4762.91
Dibromoacetonitrile 3252-43-5 5 0.000617896 396.909
Other - (non-hazardous) NA 5 0.000617896 396.909
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 30 0.00370738 2381.45
Water XTO Carrier/Base Fluid Water 7732-18-5 100 89.3337 57,384,000.0
Hydrochloric Acid (7.5%) Axiall Acidizing Hydrochloric Acid 7647-01-0 7.5 0.0379402 24371.1
Other - (non-hazardous) NA 92.5 0.882884 567126
Hydrochloric Acid 7647-01-0 7.5 0.0157487 10116.3
Hydrochloric Acid 7647-01-0 7.5 0.0178963 11495.8
Acid Inhibitor, Unihib G GeoSafe Acid Inhibitor Ethoxylated alcohol 68002-97-1 35 0.000215503 138.43
Formaldehyde 50-00-0 1 0.00000616 3.955
Acetophenone 98-86-2 1 0.00000616 3.955
Methanol 67-56-1 5 0.00003079 19.776
Short chained glycol ether 112-34-5 60 0.000369434 237.308
Thiourea 62-56-6 1 0.00000616 3.955
Hydrochloric Acid (15%) Axiall Acidizing Hydrochloric Acid 7647-01-0 15 0.0085629 5500.43
Other - (non-hazardous) NA 85 0.194092 124676
Hydrochloric Acid 7647-01-0 15 0.0181534 11660.9
Hydrochloric Acid 7647-01-0 15 0.00753535 4840.38
Scale Inhibitor, ScaleHib A Nalco Scale Inhibitor Ethylene Glycol 107-21-1 30 0.00366751 2355.84
Other - (non-hazardous) NA 70 0.00855752 5496.97
Friction Reducer, Unislick ST-50 CESI Chemical Friction Reducer Other - (non-hazardous) NA 70 0.0443605 28495.2
Petroleum distillates, hydrotreated light 64742-47-8 30 0.0190116 12212.2
Sand (Proppant) Universal Proppant Silica Substrate NA 100 9.39491 6,034,870.0

For data sources see[5]

Stimulation Data

Stimulation Date Phase Number Chemical Agent Volume (gal) Treating Pressure (psi) Breakdown Pressure (psi)
2015-03-20 1 SAND 5,359,829 7,017 5,480
2015-03-21 2 SAND 5,359,829 7,336 6,015
2015-03-21 3 SAND 5,359,829 7,011 6,465
2015-03-23 4 SAND 5,359,829 7,083 4,404
2015-03-25 5 SAND 5,359,829 7,042 4,640
2015-03-26 6 SAND 5,359,829 6,974 3,928
2015-03-27 7 SAND 5,359,829 6,843 4,868
2015-03-27 8 SAND 5,359,829 7,611 6,279
2015-03-28 9 SAND 5,359,829 7,280 6,805
2015-03-30 10 SAND 5,359,829 7,178 3,699
2015-03-30 11 SAND 5,359,829 6,847 4,640
2015-04-01 12 SAND 5,359,829 6,835 4,790
2015-04-03 13 SAND 5,359,829 6,825 6,051
2015-04-06 14 SAND 5,359,829 7,250 5,846
2015-04-07 15 SAND 5,359,829 7,046 5,440
2015-04-08 16 SAND 5,359,829 6,781 6,873
2015-04-09 17 SAND 5,359,829 6,950 5,800
2015-04-10 18 SAND 5,359,829 6,798 6,716
2015-04-11 19 SAND 5,359,829 7,191 6,250
2015-04-13 20 SAND 5,359,829 7,316 4,554

For data sources see[6]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2014 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2015 XTO ENERGY INC 0.00 0 0.00 0 0.00 0
2016 XTO ENERGY INC 710,807.00 324 0.00 0 0.00 0
2017 XTO ENERGY INC 1,440,526.00 364 0.00 0 0.00 0
2018 XTO ENERGY INC 1,163,956.86 365 0.00 0 0.00 0
2019 XTO ENERGY INC 819,164.95 353 0.00 0 0.00 0

For data sources see[7]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2014 XTO ENERGY INC Drill Cuttings 256.01 Tons LANDFILL 100434
2014 XTO ENERGY INC Drill Cuttings 57.45 Tons LANDFILL 100585
2016 XTO ENERGY INC Produced Fluid 1,691.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2016 XTO ENERGY INC Produced Fluid 1,454.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2016 XTO ENERGY INC Produced Fluid 120.00 Bbl INJECTION DISPOSAL WELL 34-133-24189
2017 XTO ENERGY INC Produced Fluid 117.40 Bbl INJECTION DISPOSAL WELL 34-133-21076
2017 XTO ENERGY INC 300.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2017 XTO ENERGY INC Produced Fluid 543.60 Bbl INJECTION DISPOSAL WELL 34-133-24189
2017 XTO ENERGY INC 3,726.90 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2017 XTO ENERGY INC 90.00 Bbl INJECTION DISPOSAL WELL 34-133-21076
2017 XTO ENERGY INC Produced Fluid 300.00 Bbl INJECTION DISPOSAL WELL 34-133-24096
2017 XTO ENERGY INC Produced Fluid 4,939.60 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2018 XTO ENERGY INC Soil Contaminated by Oil 0.31 Tons RESIDUAL WASTE PROCESSING FACILITY 101674
2018 XTO ENERGY INC Produced Fluid 169.00 Bbl INJECTION DISPOSAL WELL 34-133-24189
2018 XTO ENERGY INC Soil Contaminated by Oil & Gas Related Spills 0.31 Tons RESIDUAL WASTE PROCESSING FACILITY 101674
2018 XTO ENERGY INC Produced Fluid 3,899.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 XTO ENERGY INC Produced Fluid 753.00 Bbl RESIDUAL WASTE PROCESSING FACILITY WMGR123NW009
2019 XTO ENERGY INC Produced Fluid 87.00 Bbl INJECTION DISPOSAL WELL 34-133-24189
2019 XTO ENERGY INC Produced Fluid 476.00 Bbl INJECTION DISPOSAL WELL 34-133-24096

For data sources see[8]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2278243 Primary Facility 2014-06-12 Routine/Complete Inspection No Violations Noted Pre-operational inspection performed. Perimeter E&S controls had been installed as outlined in the E&S plan contained within the ESCGP. There was no observed accelerated erosion or sedimentation in relation to the site or access road. It was noted on the right as you enter the well pad from the access road between the silt sock and the well pad the property owner had seeded the area with soybeans.
2294439 Primary Facility 2014-08-06 Drilling/Alteration No Violations Noted Well spud in.
2294448 Primary Facility 2014-08-07 Drilling/Alteration No Violations Noted First Class Energy moving in rig#8 at time of inspection.
2296566 Primary Facility 2014-08-19 Routine/Complete Inspection No Violations Noted Drilling had commenced but was not ongoing at the time of the inspection. There was no observed accelerated erosion or sedimentation in relation to the site or access road. Secondary containment was observed onsite.
2296980 Primary Facility 2014-08-20 Drilling/Alteration No Violations Noted Waiting on rig to commence lateral drilling. First Class Energy rig#8 RD20 tophole at 5000’.
2306645 Primary Facility 2014-09-17 Drilling/Alteration No Violations Noted Waiting on frac.
2316074 Primary Facility 2014-10-27 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed and there was no ongoing well development activity or equipment located onsite. There was no observed evidence of any spills or discharges on the well-site and there was no observed accelerated erosion or sedimentation in relation to the site or access road.
2339893 Primary Facility 2015-01-30 Routine/Complete Inspection No Violations Noted Drilling had been completed, well was not equipped for production.. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2376831 Primary Facility 2015-06-08 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Site had been temporarily stabilized and there was no observed accelerated erosion or sedimentation in relation to the site or access road.
2400247 Primary Facility 2015-08-19 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Site had been temporarily stabilized and there was no observed accelerated erosion or sedimentation in relation to the site or access road.
2463626 Primary Facility 2016-03-11 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production equipment-tank battery-dike looked ok.
2481542 Primary Facility 2016-05-05 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Site had been temporarily stabilized and there was no observed accelerated erosion or sedimentation in relation to the site or access road.
2605212 Primary Facility 2017-06-19 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion in relation to the site or access road.
2680632 Primary Facility 2018-01-10 Routine/Partial Inspection No Violations Noted At time of inspection, 5H and 7H are both drilled and appear equipped for production.

For data sources see[9]

References