Well Details

Well ID: 37-005-31115
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Boggs Township
Operator Name: SNYDER BROS INC
Well Pad ID: 146480
Farm/Lease Name: BVL-MCCONNELL UNIT 1M
License Status:
Spud Date:
Permit Date: 2012-12-20
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 40.889047
Longitude: -79.474425

For data sources see[1][2][3]

Well History

Date Event
2012-12-20 New Permit Application
2013-05-22 Performed Spud Operation
2013-06-01 Drilling Completion
2013-10-04 Perforation
2014-04-15 NEWLY DRILLED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-10-14 2013-10-14 6,614 163,163 0

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Other Ingredients Nabors Completion and Production Services Other Ingredients Water 7732-18-5 48 0.00044 0
Proprietary Proprietary 15 0.000778 0
Propylene glycol 57-55-6 15 0.017158 0
Phosphoric Acid 7664-38-2 100 0.001381 0
Solvent Proprietary 1 0.001381 0
Proprietary Proprietary 2 0.002288 0
Water 7732-18-5 87.5 0.141912 0
Polymer Proprietary 10 0.013813 0
Demineralized Water 7732-18-5 50 0.000335 0
Water 7732-18-5 50 0.069063 0
Proprietary Proprietary 1 0.001381 0
Proprietary Proprietary 50 0.002593 0
Ammonium salts Proprietary 100 0.027625 0
Water 7732-18-5 80 0.004512 0
Water 7732-18-5 60 0.003111 0
Alkyl Phosphate Ether Proprietary 1 0.001381 0
Polymer Proprietary 1 0.001381 0
Monoethanolamine Proprietary 100 0.001381 0
Proprietary Proprietary 100 0.138126 0
Water 7732-18-5 40 0.045754 0
Anionic Polyacrylamide 910644-97-2 40 0.045754 0
2-Butoxyethanol 111-76-2 13 0.000119 0
Dioxane 123-91-1 1 0.00000900 0
ammonium, (2-Hydroxyethyl)trimethyl-, chloride 67-48-1 80 0.000536 0
PA Specific 30/50 mesh Sand Nabors Completion and Production Services Sand - Bulk - Pennsylvania Crystalline Silica, quartz 14808-60-7 99.9 6.9531 0
Titanium Oxide 13463-67-7 0.1 0.00696 0
Aluminum Oxide 1344-28-1 1.1 0.076561 0
Iron Oxide 1309-37-1 0.1 0.00696 0
Super GREEN SOLV Nabors Completion and Production Services Paraffin & Scale Additives BTEX Free Aliphatic Hydrocarbon 64742-96-7 100 0.001267 0
HCL Acid (0%-7.5%) Nabors Completion and Production Services Bulk Acid Hydrogen Chloride 7647-01-0 7.5 0.011965 0
Water 7732-18-5 92.5 0.147564 0
Super 100 NE Nabors Completion and Production Services Surfactants & Foamers Isopropyl Alcohol 67-63-0 40 0.05525 0
Glycol Ether 111-76-2 5 0.006906 0
Methanol 67-56-1 15 0.020719 0
N-Cocoamidopropyl-N,N-dimethyl-N-2-hydroxypropylsulfobetaine
68139-30-0 15 0.020719 0
KR-153SL Nabors Completion and Production Services Biocides 2,2-dibromo-3-nitrilopropionamide 10222-01-2 20 0.001128 0
Polyethlyene-Glycol 25322-68-3 50 0.00282 0
ICP-1000 Nabors Completion and Production Services Iron Control Additives Anionic Copolymer Proprietary 50 0.005398 0
Propylene glycol 57-55-6 50 0.005398 0
HCl Acid (12.5%-18.0%) Nabors Completion and Production Services Bulk Acid Hydrogen Chloride 7647-01-0 18 0.029193 0
Water SNYDER BROTHERS INC Water Water 7732-18-5 100 50.405 0
PA Specific 40/70 mesh Sand Nabors Completion and Production Services Sand - Bulk - Pennsylvania Aluminum Oxide 1344-28-1 1.1 0.130019 0
Iron Oxide 1309-37-1 0.1 0.01182 0
Titanium Oxide 13463-67-7 0.1 0.01182 0
Crystalline Silica, quartz 14808-60-7 99.9 11.8081 0
Nitrogen per MSCF Nabors Completion and Production Services Nitrogen Materials Nitrogen 7727-37-9 100 30.2164 0
WFR-3B Nabors Completion and Production Services Friction Reducer Ethoxylated oleylamine 26635-93-8 5 0.005719 0
Ethoxylated alcohols 68002-97-1 15 0.017158 0
Hydrotreated light distillates, non-aromatic, BTEX free 64742-47-8 30 0.034316 0
Acid Inhibitor 2 (AI-2) Nabors Completion and Production Services Acid Corrosion Inhibitors Glycol Ethers 111-46-6 40 0.000367 0
Propargyl Alcohol 107-19-7 40 0.000367 0
Tar bases, quinoline derivs, benzyl chloride-quaternized 72480-70-7 10 0.00009200 0
Isopropyl Alcohol 67-63-0 40 0.000367 0
Ethoxylated Nonylphenol 68412-54-4 13 0.000119 0

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2013 SNYDER BROS INC 10,430.00 47 0.00 0 0.00 0
2014 SNYDER BROS INC 33,879.00 364 0.00 0 0.00 0
2015 SNYDER BROS INC 19,123.00 365 0.00 0 0.00 0
2016 SNYDER BROS INC 15,720.00 344 0.00 0 0.00 0
2017 SNYDER BROS INC 12,674.00 365 0.00 0 0.00 0
2018 SNYDER BROS INC 12,443.00 364 0.00 0 0.00 0
2019 SNYDER BROS INC 11,823.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2013 SNYDER BROS INC Fracing Fluid Waste 1,440.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW006
2013 SNYDER BROS INC Fracing Fluid Waste 1,125.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE EPA ID: 748-163
2013 SNYDER BROS INC Drilling Fluid Waste 815.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE WMGR123NW006
2013 SNYDER BROS INC Drill Cuttings 114.00 Tons ON SITE ENCAPSULATION
2013 SNYDER BROS INC Produced Fluid 90.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE EPA ID: 748-163
2013 SNYDER BROS INC Fracing Fluid Waste 1,125.00 Bbl CENT WASTE TRT FAC NPDES EPA ID: 748-163
2013 SNYDER BROS INC Produced Fluid 250.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2013 SNYDER BROS INC Produced Fluid 90.00 Bbl CENT WASTE TRT FAC NPDES EPA ID: 748-163
2014 SNYDER BROS INC Produced Fluid 110.00 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW009
2014 SNYDER BROS INC Produced Fluid 95.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2014 SNYDER BROS INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-21447
2015 SNYDER BROS INC Produced Fluid 94.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2016 SNYDER BROS INC Produced Fluid 120.00 Bbl REUSE OTHER THAN ROAD SPREADING
2018 SNYDER BROS INC Produced Fluid 112.00 Bbl INJECTION DISPOSAL WELL 34-099-23158
2019 SNYDER BROS INC Produced Fluid 90.00 Bbl INJECTION DISPOSAL WELL 34-099-23158

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2168115 Primary Facility 2013-05-15 Routine/Complete Inspection No Violations Noted Drilling was not ongoing at the time of the inspection. Well-site constructed in accordance with the E&S plan located onsite. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. Drill pit located onsite and it contained minimal fluids. Drill pit liner appeared to be intact.
2177838 Primary Facility 2013-06-25 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. Drill pit located onsite and it contained drill cuttings and fluids. Drill pit had more than the required two feet of lined freeboard.
2200272 Primary Facility 2013-08-30 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. Drill pit located onsite and it contained drill cuttings and fluids. Drill pit had more than the required two feet of lined freeboard.
2235754 Primary Facility 2014-01-13 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Site had been regraded and seeded and mulched. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2248090 Primary Facility 2014-02-25 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Site had been regraded and seeded and mulched. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2395677 Primary Facility 2015-08-04 Site Restoration No Violations Noted Well appeared to be equipped for production, brine tanks located onsite and they appeared to be in sound condition. Site had been properly restored and the vegetation had attained 70% uniform coverage.. There was no observed accelerated erosion or sedimentation in relation to the site or access road.

For data sources see[8]