Well Details

Well ID: 37-005-30896
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Rayburn Township
Operator Name: EXCO RESOURCES PA LLC
Well Pad ID: 149443
Farm/Lease Name: TICKLE FARM PAD 1H
License Status:
Spud Date:
Permit Date: 2011-10-12
Well Type: GAS
Unconventional Well: Y
Configuration: Horizontal Well
Conservation: Yes
Latitude: 40.842916
Longitude: -79.473120

For data sources see[1][2][3]

Well History

Date Event
2011-10-12 New Permit Application
2012-08-21 Performed Spud Operation
2012-10-20 Drilling Completion
2013-01-04 Perforation
2014-04-14 DEVIATED

For data sources see[4]

Fracking Activities

Fracking Jobs

Job Number Job Start Date Job End Date True Vertical Depth (ft) Total Water Volume (gal) Total Non-Water Volume (gal)
1 2013-01-05 2013-01-05 6,730 4,411,088

Fluid Composition Data

Job Number Trade Name Supplier Purpose Ingredient Name CAS Number Additive Percentage by Mass Job Percentage by Mass Mass Used (lb)
1 Hydrochloric Acid Calfrac Well Services Clean Perforations Polyacrylamide polymer 40.00 0.03
Thiourea polymer 68527-49-1 30.00 0.00040000
Sodium chloride 7647-14-5 1.00 0.00001000
Polyethylene glycol 25322-68-3 70.00 0.01
Illite 12173-60-3 1.00 0.00779000
Citric acid 77-92-9 60.00 0.00285000
Oxyalkylated polyamine 5.00 0.00095000
Apatite 64476-38-6 0.10 0.00400000
Acetic acid 64-19-7 1.00 0.00019000
Ammonium chloride 12125-02-9 10.00 0.00113000
Hydrochloric acid 7647-01-0 37.00 0.28
Biotite 1302-27-8 0.10 0.00400000
Polyoxyalkylenes surfactant 5.00 0.00476000
Goethite 1310-14-1 0.10 0.00624000
Distillates, petroleum, hydrotreated light 64742-47-8 30.00 0.02
Olefin 5.00 0.00007000
Carbonic acid calcium salt (1:1) 471-34-1 1.00 0.02
Amine salt 5.00 0.00095000
Ilmenite (FeTiO3), conc. 98072-94-7 0.10 0.00288000
Organic phosphonate 2 10.00 0.00189000
Methanol 67-56-1 60.00 0.00648000
Propargyl Alcohol 10.00 0.00013000
Nonionic surfactant 5.00 0.00476000
Polyoxyalkylenes 30.00 0.00040000
2,2-Dibromo-3-nitrilopropionamide 10222-01-2 40.00 0.01
Organic phosphonate 1 30.00 0.00567000
Quartz 14808-60-7 100.00 14.00
Fatty acids 30.00 0.00040000
Formalin 50-00-0 0.10 0.00003000
DAP-925 Calfrac Well Services Acid Corrosion Inhibitor
Sand (Proppant) Calfrac Well Services Propping Agent
Water BaseFluid/Mix Water Water 7732-18-5 100.00 85.58
DAP-901 Calfrac Well Services Scale Inhibitor
DWP-944 Calfrac Well Services Biocide
DWP-612 Calfrac Well Services Friction Reducer
DAP-103 Calfrac Well Services Iron Control

For data sources see[5]

Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2011 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2012 EXCO RESOURCES PA LLC 0.00 0 0.00 0 0.00 0
2013 EXCO RESOURCES PA LLC 401,223.00 184 0.00 0 0.00 0
2014 EXCO RESOURCES PA LLC 503,227.00 365 0.00 0 0.00 0
2015 EXCO RESOURCES PA LLC 365,127.00 365 0.00 0 0.00 0
2016 EXCO RESOURCES PA LLC 305,154.00 353 0.00 0 0.00 0
2017 EXCO RESOURCES PA LLC 277,270.00 361 0.00 0 0.00 0
2018 EXCO RESOURCES PA LLC 236,313.00 363 0.00 0 0.00 0
2019 EXCO RESOURCES PA LLC 210,648.00 365 0.00 0 0.00 0

For data sources see[6]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2012 EXCO RESOURCES PA LLC Drill Cuttings 813.14 Tons LANDFILL 100434
2013 EXCO RESOURCES PA LLC Produced Fluid 710.69 Bbl INJECTION DISPOSAL WELL 34-013-20611
2013 EXCO RESOURCES PA LLC Produced Fluid 82.50 Bbl RESIDUAL WASTE PROC FAC (GENERAL PERMIT) WMGR123NW006
2013 EXCO RESOURCES PA LLC Produced Fluid 1,757.49 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EXCO RESOURCES PA LLC Produced Fluid 1,036.70 Bbl INJECTION DISPOSAL WELL 34-059-24067
2013 EXCO RESOURCES PA LLC Fracing Fluid Waste 8,299.00 Bbl REUSE OTHER THAN ROAD SPREADING
2013 EXCO RESOURCES PA LLC Fracturing Fluid Waste 54.07 Tons LANDFILL 100434
2013 EXCO RESOURCES PA LLC Produced Fluid 8,658.24 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2014 EXCO RESOURCES PA LLC Produced Fluid 54.26 Bbl INJECTION DISPOSAL WELL 34-059-24067
2014 EXCO RESOURCES PA LLC Produced Fluid 5,738.99 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2014 EXCO RESOURCES PA LLC Fracturing Fluid Waste 3.54 Tons LANDFILL 100434
2015 EXCO RESOURCES PA LLC Produced Fluid 3,731.80 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid 1,941.70 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2016 EXCO RESOURCES PA LLC Produced Fluid 489.30 Bbl REUSE OTHER THAN ROAD SPREADING
2017 EXCO RESOURCES PA LLC Produced Fluid 2,062.30 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC 1,424.30 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2017 EXCO RESOURCES PA LLC Produced Fluid 103.60 Bbl REUSE (AT WELL PAD)
2017 EXCO RESOURCES PA LLC 103.60 Bbl REUSE (AT WELL PAD)
2018 EXCO RESOURCES PA LLC Produced Fluid 234.80 Bbl INJECTION DISPOSAL WELL 34-007-21847
2018 EXCO RESOURCES PA LLC Produced Fluid 1,398.60 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE
2019 EXCO RESOURCES PA LLC Produced Fluid 1,372.70 Bbl INJECTION DISPOSAL WELL PAS2D205BCLE

For data sources see[7]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2094852 Primary Facility 2012-08-22 Drilling/Alteration No Violations Noted at 87' Notification provided
2097767 Primary Facility 2012-09-04 Routine/Complete Inspection No Violations Noted Drilling had commenced, but was not ongoing at the time of the inspection due to a changeover in drilling rigs. Secondary containement was noted as being implemented on the well pad. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. All erosion controls had been implemented and were functioning properly. Frac impoundment located onsite. At the time of the inspection the frac impoundment had not been lined and was holding rainwater.
2103813 Primary Facility 2012-09-20 Drilling/Alteration No Violations Noted @ 410'
2105768 Primary Facility 2012-10-04 Drilling/Alteration No Violations Noted Preparing to resume drilling
2109432 Primary Facility 2012-10-19 Drilling/Alteration No Violations Noted Preparing to install 5.5 production string
2111841 Primary Facility 2012-10-23 Drilling/Alteration No Violations Noted TD prod casing cemented
2144811 Primary Facility 2013-03-04 Routine/Complete Inspection No Violations Noted Drilling appeared to have been completed. Secondary containment was implemented around the well head and under the 18 tanks located onsite to handle flowback. All site and access road erosion controls had been properly maintained and there was no observed accelerated erosion or sedimentation in relation to the site or access road.
2166173 Primary Facility 2013-05-14 Routine/Complete Inspection No Violations Noted Drilling was not ongoing at the time of the inspection. Wells were in the process of being equipped for production. Brine tanks located onsite and they appeared to be in sound condition. Covered roll-off boxes onsite within secondary containment. 16 Frac tanks located onsite also on secondary containment. All frac tanks appeared to be in sound condition. Operator was in the process of having the tanks cleaned and broken down for removal from the site. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2197000 Primary Facility 2013-08-15 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2230472 Primary Facility 2013-12-09 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Erosion controls had been properly implemented and maintained. Site had been temporarily stabilized. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. Impoundment located onsite. Impoundment contained fluids and had more than two feet of lined freeboard.
2287250 Primary Facility 2014-07-15 Complaint Inspection No Violations Noted 4 wells on pad. Producing gas. Tag, tanks, e&s ok.
2293430 Primary Facility 2014-08-05 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Erosion controls had been properly implemented and maintained. Site had been temporarily stabilized. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. Impoundment located onsite. Impoundment contained fluids and had more than two feet of lined freeboard.
2333351 Primary Facility 2015-01-05 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite and it appeared to be in sound condition. Erosion controls had been properly implemented and maintained. Site had been temporarily stabilized. There was no observed accelerated erosion or sedimentation in relation to the access road or well-site. Impoundment located onsite. Impoundment contained fluids and had more than two feet of lined freeboard.
2377649 Primary Facility 2015-06-09 Complaint Inspection No Violations Noted 4 wells equipped for production. Id sign and e&s ok. 2 tanks onsite.
2540132 Primary Facility 2016-11-30 Routine/Complete Inspection No Violations Noted Wells were appropriately labeled and brine tanks located onsite. Brine tanks appeared to be in sound condition. There was no observed accelerated erosion & sedimentation in relation to the site or access road.
2556548 Primary Facility 2017-01-30 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production set equipment-tank battery-dike containment looked ok.
2621957 Primary Facility 2017-08-02 Routine/Complete Inspection No Violations Noted Well appeared to be equipped for production. Brine tank located onsite within containment. Both the tank and containment appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road.
2673036 Primary Facility 2017-12-20 Routine/Complete Inspection No Violations Noted At time of inspection, well 1H drilled and appears equipped for production. Wells 2H, 3H, 4H also drilled and appear equipped for production.
2722659 Primary Facility 2018-04-25 Routine/Complete Inspection No Violations Noted Multi-well pad. At time of inspection, well 1H drilled and appears equipped for production. Wells 2H, 3H, and 4H also drilled and appear equipped for production.
2743019 Primary Facility 2018-06-19 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The well head casing, piping, production set equipment, tank battery and containment dike look ok.
2799025 Primary Facility 2018-11-05 Routine/Complete Inspection No Violations Noted Well appears equipped for production. Well had surrounded by cement barriers. Two brine tanks on site.
2831986 Primary Facility 2019-01-23 Routine/Partial Inspection No Violations Noted At the time of inspection, well was equipped for production. The well integrity appeared to be in good condition, with no signs of any leaks. There was only some minor rust observed. The well was being injected with a foamer combo. The gauges on the well were reading 281 psi on the tubing and 408 psi on the production casing. There were 2 tanks within a lined, steel dike. There were also 2 dual line heaters being used. The well was properly labeled and the Emergency Response sign was posted at the site access entrance.
2837793 Primary Facility 2019-02-08 Routine/Complete Inspection No Violations Noted On 2/8/19 at 1203 hrs., I conducted a routine inspection of Exco Resources PA, LLC's Tickle Farm Pad 1H well (API 005-30896) in Rayburn Twp., Armstrong Co. It is one of four permitted wells that are drilled and equipped for production. A well tag is affixed to the well head. The permit number is posted at the entrance to the pad. There are no violations noted for this inspection.

For data sources see[8]