If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 37-005-30676 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.888822,"lon":-79.421797,"icon":""}]} |
Country: United States | |
State: Pennsylvania | |
County: Armstrong | |
Municipality: Boggs Township | |
Operator Name: SNYDER BROS INC | |
Well Pad ID: 146583 | |
Farm/Lease Name: BVL/SHAWMUT 2M-100 | |
License Status: | |
Spud Date: | |
Permit Date: 2010-06-29 | |
Well Type: GAS | |
Unconventional Well: Y | |
Configuration: Vertical Well | |
Conservation: Yes | |
Latitude: 40.888822 | |
Longitude: -79.421797 |
Date | Event |
---|---|
2010-06-29 | New Permit Application |
2011-04-01 | Performed Spud Operation |
2011-04-08 | Drilling Completion |
2012-02-23 | New Permit Application |
2012-12-06 | Drilling Completion |
2013-08-23 | Perforation |
2014-04-14 | DRILLED DEEPER |
2014-05-06 | NEWLY DRILLED |
For data sources see[4]
Job Number | Job Start Date | Job End Date | True Vertical Depth (ft) | Total Water Volume (gal) | Total Non-Water Volume (gal) |
---|---|---|---|---|---|
1 | 2013-08-27 | 2013-08-28 | 6,638 | 181,697 | 0 |
Job Number | Trade Name | Supplier | Purpose | Ingredient Name | CAS Number | Additive Percentage by Mass | Job Percentage by Mass | Mass Used (lb) |
---|---|---|---|---|---|---|---|---|
1 | Super 100 NE | Nabors Completion and Production Services | Surfactants & Foamers | Methanol | 67-56-1 | 15 | 0.0207 | 0 |
Glycol Ether | 111-76-2 | 5 | 0.0069 | 0 | ||||
N-Cocoamidopropyl-N,N-dimethyl-N-2-hydroxypropylsulfobetaine |
68139-30-0 | 15 | 0.0207 | 0 | ||||
Isopropyl Alcohol | 67-63-0 | 40 | 0.0552 | 0 | ||||
Super GREEN SOLV-M | Nabors Completion and Production Services | Paraffin & Scale Additives | Tridecane | Proprietary | 9 | 0.00009500 | 0 | |
tetradecane | Proprietary | 11 | 0.000116 | 0 | ||||
Dodecane | Proprietary | 14 | 0.000147 | 0 | ||||
Undecane | Proprietary | 8 | 0.00008400 | 0 | ||||
Aliphatic Hydrocarbons | Proprietary | 95 | 0.000998 | 0 | ||||
WFR-3B | Nabors Completion and Production Services | Friction Reducer | Hydrotreated light distillates, non-aromatic, BTEX free | 64742-47-8 | 30 | 0.033363 | 0 | |
Ethoxylated oleylamine | 26635-93-8 | 5 | 0.00556 | 0 | ||||
Ethoxylated alcohols | 68002-97-1 | 15 | 0.016681 | 0 | ||||
Other Ingredients | Nabors Completion and Production Services | Other Ingredients | Water | 7732-18-5 | 48 | 0.000403 | 0 | |
Water | 7732-18-5 | 40 | 0.044484 | 0 | ||||
Solvent | Proprietary | 1 | 0.00138 | 0 | ||||
Monoethanolamine | Proprietary | 100 | 0.00138 | 0 | ||||
Proprietary | Proprietary | 1 | 0.00138 | 0 | ||||
Proprietary | Proprietary | 100 | 0.138001 | 0 | ||||
Alkyl Phosphate Ether | Proprietary | 1 | 0.00138 | 0 | ||||
Water | 7732-18-5 | 50 | 0.069 | 0 | ||||
Polymer | Proprietary | 10 | 0.0138 | 0 | ||||
Anionic Polyacrylamide | 910644-97-2 | 40 | 0.044484 | 0 | ||||
Water | 7732-18-5 | 87.5 | 0.129767 | 0 | ||||
ammonium, (2-Hydroxyethyl)trimethyl-, chloride | 67-48-1 | 80 | 0.00049 | 0 | ||||
Water | 7732-18-5 | 60 | 0.002845 | 0 | ||||
Propylene glycol | 57-55-6 | 15 | 0.016681 | 0 | ||||
Proprietary | Proprietary | 2 | 0.002224 | 0 | ||||
Water | 7732-18-5 | 80 | 0.004125 | 0 | ||||
Proprietary | Proprietary | 50 | 0.002371 | 0 | ||||
Polymer | Proprietary | 1 | 0.00138 | 0 | ||||
Dioxane | 123-91-1 | 1 | 0.00000800 | 0 | ||||
Ammonium salts | Proprietary | 100 | 0.0276 | 0 | ||||
Proprietary | Proprietary | 15 | 0.000711 | 0 | ||||
Phosphoric Acid | 7664-38-2 | 100 | 0.00138 | 0 | ||||
2-Butoxyethanol | 111-76-2 | 13 | 0.000109 | 0 | ||||
Demineralized Water | 7732-18-5 | 50 | 0.000306 | 0 | ||||
ICP-1000 | Nabors Completion and Production Services | Iron Control Additives | Anionic Copolymer | Proprietary | 50 | 0.004936 | 0 | |
Propylene glycol | 57-55-6 | 50 | 0.004936 | 0 | ||||
PA Specific 40/70 mesh Sand | Nabors Completion and Production Services | Sand - Bulk - Pennsylvania | Crystalline Silica, quartz | 14808-60-7 | 99.9 | 10.9972 | 0 | |
Aluminum Oxide | 1344-28-1 | 1.1 | 0.12109 | 0 | ||||
Iron Oxide | 1309-37-1 | 0.1 | 0.011008 | 0 | ||||
Titanium Oxide | 13463-67-7 | 0.1 | 0.011008 | 0 | ||||
Water | SNYDER BROTHERS INC | Water | Water | 7732-18-5 | 100 | 51.327 | 0 | |
PA Specific 30/50 mesh Sand | Nabors Completion and Production Services | Sand - Bulk - Pennsylvania | Aluminum Oxide | 1344-28-1 | 1.1 | 0.064792 | 0 | |
Titanium Oxide | 13463-67-7 | 0.1 | 0.00589 | 0 | ||||
Iron Oxide | 1309-37-1 | 0.1 | 0.00589 | 0 | ||||
Crystalline Silica, quartz | 14808-60-7 | 99.9 | 5.88434 | 0 | ||||
HCl Acid (12.5%-18.0%) | Nabors Completion and Production Services | Bulk Acid | Hydrogen Chloride | 7647-01-0 | 18 | 0.026695 | 0 | |
Nitrogen per MSCF | Nabors Completion and Production Services | Nitrogen Materials | Nitrogen | 7727-37-9 | 100 | 31.2089 | 0 | |
Acid Inhibitor 2 (AI-2) | Nabors Completion and Production Services | Acid Corrosion Inhibitors | Tar bases, quinoline derivs, benzyl chloride-quaternized | 72480-70-7 | 10 | 0.00008400 | 0 | |
Isopropyl Alcohol | 67-63-0 | 40 | 0.000336 | 0 | ||||
Glycol Ethers | 111-46-6 | 40 | 0.000336 | 0 | ||||
Propargyl Alcohol | 107-19-7 | 40 | 0.000336 | 0 | ||||
Ethoxylated Nonylphenol | 68412-54-4 | 13 | 0.000109 | 0 | ||||
KR-153SL | Nabors Completion and Production Services | Biocides | Polyethlyene-Glycol | 25322-68-3 | 50 | 0.002578 | 0 | |
2,2-dibromo-3-nitrilopropionamide | 10222-01-2 | 20 | 0.001031 | 0 | ||||
HCL Acid (0%-7.5%) | Nabors Completion and Production Services | Bulk Acid | Water | 7732-18-5 | 92.5 | 0.134936 | 0 | |
Hydrogen Chloride | 7647-01-0 | 7.5 | 0.010941 | 0 |
For data sources see[5]
Period | Operator Name | Gas Quantity (mcf) | Gas Production Days | Oil Quantity (bbl) | Oil Production Days | Water Quantity (bbl) | Water Production Days |
---|---|---|---|---|---|---|---|
2010 | SNYDER BROS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2011 | SNYDER BROS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2012 | SNYDER BROS INC | 0.00 | 0 | 0.00 | 0 | 0.00 | 0 |
2013 | SNYDER BROS INC | 31,830.00 | 88 | 0.00 | 0 | 0.00 | 0 |
2014 | SNYDER BROS INC | 61,527.00 | 363 | 0.00 | 0 | 0.00 | 0 |
2015 | SNYDER BROS INC | 37,351.00 | 348 | 0.00 | 0 | 0.00 | 0 |
2016 | SNYDER BROS INC | 28,020.00 | 349 | 0.00 | 0 | 0.00 | 0 |
2017 | SNYDER BROS INC | 23,368.00 | 359 | 0.00 | 0 | 0.00 | 0 |
2018 | SNYDER BROS INC | 21,876.00 | 355 | 0.00 | 0 | 0.00 | 0 |
2019 | SNYDER BROS INC | 19,390.00 | 353 | 0.00 | 0 | 0.00 | 0 |
For data sources see[6]
Period | Operator | Waste Type | Quantity | Disposal Method | Waste Facility ID |
---|---|---|---|---|---|
2012 | SNYDER BROS INC | Drill Cuttings | 53.00 Tons | ON SITE ENCAPSULATION | |
2013 | SNYDER BROS INC | Fracing Fluid Waste | 1,710.00 Bbl | RESIDUAL WASTE PROC FAC (GENERAL PERMIT) | WMGR123NW006 |
2013 | SNYDER BROS INC | Produced Fluid | 80.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2013 | SNYDER BROS INC | Fracing Fluid Waste | 370.00 Bbl | CENT WASTE TRT FAC NPDES DISCHARGE | EPA ID: 748-163 |
2013 | SNYDER BROS INC | Fracing Fluid Waste | 695.00 Bbl | REUSE OTHER THAN ROAD SPREADING | |
2013 | SNYDER BROS INC | Fracing Fluid Waste | 370.00 Bbl | CENT WASTE TRT FAC NPDES | EPA ID: 748-163 |
2014 | SNYDER BROS INC | Produced Fluid | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21438 |
2014 | SNYDER BROS INC | Produced Fluid | 95.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23732 |
2014 | SNYDER BROS INC | Produced Fluid | 93.00 Bbl | INJECTION DISPOSAL WELL | 34-155-21447 |
2016 | SNYDER BROS INC | Produced Fluid | 110.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23196 |
2017 | SNYDER BROS INC | Produced Fluid | 36.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 |
2017 | SNYDER BROS INC | 36.00 Bbl | INJECTION DISPOSAL WELL | 34-155-23223 | |
2018 | SNYDER BROS INC | Produced Fluid | 60.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
2019 | SNYDER BROS INC | Produced Fluid | 90.00 Bbl | INJECTION DISPOSAL WELL | 34-099-23158 |
For data sources see[7]
Inspection ID | Inspection Category | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|---|
1957413 | Primary Facility | 2011-03-15 | Routine/Complete Inspection | No Violations Noted | Site constructed, drilling had not commenced. E&S plan had been implemented as outlined. The erosion controls, if maintained properly, should effectively minimize accelerated erosion & sedimentation. |
1968046 | Primary Facility | 2011-04-25 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed. Well was not equipped for production. Drill pit contained drill cuttings and fluids. Pit had more than the required two feet of lined freeboard. No accelerated erosion or sedimentation in relation to the access road or site. |
2044960 | Primary Facility | 2012-02-23 | Site Restoration | No Violations Noted | Well was not equipped for production. There was no observed accelerated erosion or sedimentation observed in relation to the access road or well-site. |
2082456 | Primary Facility | 2012-07-11 | Routine/Complete Inspection | No Violations Noted | Drilling was not ongoing at the time of the inspection. Drill pit had been regraded. There was no observed accelerated erosion or sedimentation in relation to the well or access road. |
2119254 | Primary Facility | 2012-11-29 | Routine/Complete Inspection | No Violations Noted | Well-site had been enlarged and a new drill pit had been excavated. Drill pit was properly lined and contained no fluids or solids at the time of the inspection. Site had been temporarily stabilized and the site erosion controls had been properly implemented. |
2123907 | Primary Facility | 2012-11-12 | Drilling/Alteration | No Violations Noted | Drilling complete |
2131601 | Primary Facility | 2013-01-17 | Routine/Complete Inspection | No Violations Noted | Drilling was completed on 12/05/12, well was not stimulated. Drill pit located onsite and it had more than the required two feet of lined freeboard. Access road and site erosion controls appeared to be functioning properly and there was no evidence of accelerated erosion or sedimenation observed. The Department recommends that the operator inspect site and access road controls after the most recent snowfall has melted or well stimulation activities are commenced, whichever is sooner. |
2144755 | Primary Facility | 2013-03-04 | Routine/Complete Inspection | No Violations Noted | Drilling was completed on 12/05/12, well was not stimulated. Drill pit located onsite and it had more than the required two feet of lined freeboard. Access road and site erosion controls appeared to be functioning properly and there was no evidence of accelerated erosion or sedimenation observed. |
2168421 | Primary Facility | 2013-05-22 | Routine/Complete Inspection | No Violations Noted | Drilling appeared to have been completed, well was not equipped for production. Drill pit located onsite and it had more than the required two feet of lined freeboard. Access road and site erosion controls appeared to be functioning properly and there was no evidence of accelerated erosion or sedimenation observed. |
2196954 | Primary Facility | 2013-08-12 | Routine/Complete Inspection | No Violations Noted | Drilling was completed on 12/06/12, well was not stimulated. Drill pit located onsite and it had more than the required two feet of lined freeboard. Access road and site erosion controls appeared to be functioning properly and there was no evidence of accelerated erosion or sedimentation observed. |
2243403 | Primary Facility | 2014-02-06 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production. Brine tanks located onsite and they appeared to be in sound condition. The site had been properly restored and there was no observed accelerated erosion or sedimentation. |
2383148 | Primary Facility | 2015-06-29 | Routine/Complete Inspection | No Violations Noted | Well appeared to be equipped for production, brine tanks located onsite and they appeared to be in sound condition. There was no observed accelerated erosion or sedimentation in relation to the site or access road. |
2748360 | Primary Facility | 2018-07-03 | Routine/Complete Inspection | No Violations Noted | This well is tagged and in production. The annulus is open. The well head casing, piping, production set equipment and 2 grounded 100 bbl fiberglass fluid collection tanks look ok. |
For data sources see[8]