X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-005-30381

Well Details

Well ID: 37-005-30381
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: East Franklin Township
Operator Name: SNYDER BROS INC
Well Pad ID: 146142
Farm/Lease Name: C H SNYDER CO UNIT
License Status: Plugged and Abandoned
Spud Date: 2010-04-23
Permit Date: 2009-06-30
Well Type: GAS
Unconventional Well: Y
Configuration: Vertical Well
Conservation: Yes
Latitude: 40.836610
Longitude: -79.554152

For data sources see[1][2][3]

Well History

Date Event
2009-06-30 New Permit Application
2010-04-21 Performed Spud Operation
2010-05-01 Drilling Completion
2010-07-01 Perforation
2013-05-15 NEWLY DRILLED
2018-05-01 Begin Plugging
2018-05-04 Finished Plugging
2018-08-23 Fully Plugged

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 SNYDER BROS INC 25,316.00 143 0.00 0 0.00 0
2011 SNYDER BROS INC 29,621.00 292 0.00 0 0.00 0
2012 SNYDER BROS INC 26,830.00 361 0.00 0 0.00 0
2013 SNYDER BROS INC 20,420.00 360 0.00 0 0.00 0
2014 SNYDER BROS INC 15,953.00 360 0.00 0 0.00 0
2015 SNYDER BROS INC 14,045.00 358 0.00 0 0.00 0
2016 SNYDER BROS INC 15,037.00 361 0.00 0 0.00 0
2017 SNYDER BROS INC 11,410.00 352 0.00 0 0.00 0
2018 SNYDER BROS INC 2,759.00 110 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 SNYDER BROS INC Produced Fluid 965.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 SNYDER BROS INC Produced Fluid 220.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2011 SNYDER BROS INC Produced Fluid 180.00 Bbl INJECTION DISPOSAL WELL 34-155-23795
2012 SNYDER BROS INC Produced Fluid 160.00 Bbl INJECTION DISPOSAL WELL 34-155-21438
2012 SNYDER BROS INC Produced Fluid 80.00 Bbl INJECTION DISPOSAL WELL 34-155-23584
2013 SNYDER BROS INC Produced Fluid 94.00 Bbl INJECTION DISPOSAL WELL 34-155-21893
2014 SNYDER BROS INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-23759
2015 SNYDER BROS INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-23732
2016 SNYDER BROS INC Produced Fluid 93.00 Bbl INJECTION DISPOSAL WELL 34-155-23196
2017 SNYDER BROS INC Produced Fluid 95.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2017 SNYDER BROS INC 95.00 Bbl INJECTION DISPOSAL WELL 34-155-23223
2018 SNYDER BROS INC Produced Fluid 15.00 Bbl INJECTION DISPOSAL WELL 34-099-23158

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1800201 Primary Facility 2009-05-21 Routine/Complete Inspection No Violations Noted Well staked, site not constructed at the time of the inspection. Met onsite with operator representatives Todd Kunselman and Doug Miller to review the proposed site and existing access road. The E&S plan as submitted should effectively minimize accelerated erosion & sedimentation, provided the erosion control measures are implemented and maintained properly.
1882318 Primary Facility 2010-04-27 Routine/Complete Inspection No Violations Noted Drill rig was on-site during the inspection. Drill pit appears to be in sound condition. Located the Site ID sign and E&S plan. E&S controls such as silt fence and rocked culverts have been installed. The operator has already seeded and mulched many of the disturbed areas. At this time, there are no signs of erosion or sedimentation on the access road or well site.
1883728 Primary Facility 2010-04-26 Drilling/Alteration No Violations Noted MARCELLUS - drilling/E&S ok/ID&pit ok
1894959 Primary Facility 2010-06-29 Complaint Inspection No Violations Noted shawn clark called said had oil taste in spring water, turned over to wqs
1896395 Primary Facility 2010-06-30 Complaint Inspection No Violations Noted Frac crews on-site at the time of the inspection. Site ID sign and E&S plan located. The pit appears to be in sound condition. No visible signs of a brine release or pit failure. No E&S concerns at this time.
1919204 Primary Facility 2010-09-28 Routine/Complete Inspection No Violations Noted Well is equipped for production. Tag located. Brine tanks appear to be in sound condition. The site was recently seeded & mulched. No E&S concerns at this time.
2082730 Primary Facility 2012-07-12 Site Restoration No Violations Noted At the time of inspection the well appeared to be drilled and equipped for production. The associated well apparatus, brine tank, and pump jack located onsite appear to be in sound condition. The site is restored and meets the 70% uniform vegetative coverage criteria.
2448897 Primary Facility 2016-02-11 Routine/Complete Inspection No Violations Noted Well tagged-in production. Well head casing-production equipment- 2-100 bbl tanks look ok.
2725239 Primary Facility 2018-05-02 Routine/Complete Inspection No Violations Noted Inspection conducted in response to electronic plugging notification submitted by operator. At time of inspection, rig on-site actively working on well.
2727925 Primary Facility 2018-05-09 Plugging(Includes Plugged/Mined Through) No Violations Noted The operator has just finished plugging this well and the rig was gone at the time of this inspection. The well was cemented solid from the TD to surface and a monument with the well API number permanently affixed to it was set.
2819944 Primary Facility 2018-12-27 Site Restoration No Violations Noted Inspection conducted in response to a Post Plugging Site Restoration Report received by Department.

At time of inspection well is plugged. Monument present with permit number permanently affixed (photo #1). No E and S issues observed on site. Site appears to be returned to near original contours. Vegetation appears to have reached >70% uniform growth. This Restoration Report is approved.

For data sources see[7]

References