37-005-30218

Well Details

Well ID: 37-005-30218
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Mahoning Township
Operator Name: SNYDER BROS INC
Well Pad ID:
Farm/Lease Name: ARMCLAR GAS COMPANY 3-130
License Status:
Spud Date:
Permit Date: 2009-02-19
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.930733
Longitude: -79.350334

For data sources see[1][2][3]

Well History

Date Event
2009-02-19 New Permit Application
2010-02-01 Performed Spud Operation
2010-02-05 Drilling Completion
2010-06-11 Perforation
2012-11-08 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
2010 SNYDER BROS INC 5,055.00 156 0.00 0 0.00 0
2011 SNYDER BROS INC 4,305.00 318 0.00 0 0.00 0
2012 SNYDER BROS INC 3,275.00 351 51.00 351 0.00 0
2013 SNYDER BROS INC 2,936.00 363 0.00 0 0.00 0
2014 SNYDER BROS INC 2,492.00 364 50.00 364 0.00 0
2015 SNYDER BROS INC 1,703.00 343 0.00 0 0.00 0
2016 SNYDER BROS INC 2,127.00 320 43.58 25 0.00 0
2017 SNYDER BROS INC 2,075.00 344 0.00 0 0.00 0
2018 SNYDER BROS INC 1,358.00 336 44.13 30 0.00 0
2019 SNYDER BROS INC 1,490.00 347 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2010 SNYDER BROS INC Produced Fluid 60.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0091472
2011 SNYDER BROS INC Produced Fluid 20.00 Bbl ROAD SPREADING
2011 SNYDER BROS INC Produced Fluid 15.00 Bbl CENTRALIZED TREATMENT PLANT FOR RECYCLE PA0101508
2015 SNYDER BROS INC Produced Fluid 16 Bbl CENT WASTE TRT FAC NPDES PA0095273
2015 SNYDER BROS INC Produced Fluid 16.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273
2019 SNYDER BROS INC Produced Fluid 15.00 Bbl CENT WASTE TRT FAC NPDES DISCHARGE PA0095273

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
1860443 Primary Facility 2010-02-02 Drilling/Alteration No Violations Noted Drilling 12 3/8" at 145' 3" H2O @ 60'. Drilling suspended due to fluid level in pit.
1861219 Primary Facility 2010-02-04 Routine/Complete Inspection No Violations Noted Pits, E&S ok. Several areas of possible concern were noted in realtion to the access road.
1872034 Primary Facility 2010-03-22 Routine/Complete Inspection No Violations Noted Drilling was completed, well was not equipped for production at the time of the inspection. Noted that the access road was realtively muddy and unstable, but this was due to the recent weather conditions. The operator should insure that the access road is regraded and stabilized as soon as the weather permits. Observed no accelerated erosion on the site. Due to the proximity of Mahoning Creek to the site and the low lying area the operator should begin site reclamation as soon as the weather permits to minimize the potential for erosion or the degradtion of the above grade pit located onsite. The pit contained the drill cuttings and minimal fluids.
1994514 Primary Facility 2011-08-09 Site Restoration No Violations Noted Drilling was completed on 02/05/10. Well appeared to be equipped for production with a pumpjack apparatus. Operator had implemented posts to protect the well apparatus from damage due to debris during a flood. Brine tank located at the Armclar Gas Company 2 site and appeared to be in sound condition. Site had been effectively restored. Observed no accelerated erosion or sedimentation in relation to the access road or well-site. Noted that the access road required routine maintenance to insure its continued passability.
2650773 Primary Facility 2017-10-23 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The annulus is open. The pump jack, which is the only piece of production equipment on site looks ok.

For data sources see[7]

References