X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

37-005-01316

Well Details

Well ID: 37-005-01316
Loading map...
Country: United States
State: Pennsylvania
County: Armstrong
Municipality: Plumcreek Township
Operator Name: ALLIANCE PETRO CO LLC
Well Pad ID:
Farm/Lease Name: H H WOOD 1
License Status: INACTIVE
Spud Date:
Permit Date:
Well Type: GAS
Unconventional Well: N
Configuration: Vertical Well
Conservation: No
Latitude: 40.683920
Longitude: -79.303126

For data sources see[1][2][3]

Well History

Date Event
1904-12-01 Drilling Completion
1986-01-01 NEWLY DRILLED

For data sources see[4]


Production Data

Period Operator Name Gas Quantity (mcf) Gas Production Days Oil Quantity (bbl) Oil Production Days Water Quantity (bbl) Water Production Days
1991 2390.00 365 0.00 0 0.00 0
1996 1043 365 0.00 0 0.00 0
1998 1305 306 0.00 0 0.00 0
1999 CONSOL GAS CO 3013 365 0.00 0 0.00 0
2000 CONSOL GAS CO 2211 365 0.00 0 0.00 0
2001 CONSOL GAS CO 922 365 0.00 0 0.00 0
2002 CONSOL GAS CO 347 365 0.00 0 0.00 0
2003 CONSOL GAS CO 195 365 0.00 0 0.00 0
2005 CONSOL GAS CO 147 365 0.00 0 0.00 0
2006 CONSOL GAS CO 0.00 0 0.00 0 0.00 0
2007 CONSOL GAS CO 0.00 0 0.00 0 0.00 0
2008 CONSOL GAS CO 0.00 0 0.00 0 0.00 0
2009 CONSOL GAS CO 89.00 365 0.00 0 0.00 0
2010 CONSOL GAS CO 206.00 365 0.00 0 0.00 0
2011 CONSOL GAS CO 0.00 0 0.00 0 0.00 0
2012 CNX GAS CO LLC 211.00 366 0.00 0 0.00 0
2013 CNX GAS CO LLC 184.00 365 0.00 0 0.00 0
2014 CNX GAS CO LLC 117.00 365 0.00 0 0.00 0
2015 CNX GAS CO LLC 66.00 365 0.00 0 0.00 0
2016 CNX GAS CO LLC 20.00 92 0.00 0 0.00 0
2017 CNX GAS CO LLC 66.00 153 0.00 0 0.00 0
2018 CNX GAS CO LLC 10.00 89 0.00 0 0.00 0
2019 ALLIANCE PETRO CO LLC 12.00 184 0.00 0 0.00 0

For data sources see[5]

Waste Data

Period Operator Waste Type Quantity Disposal Method Waste Facility ID
2006 CONSOL GAS CO Brine 0.00 Bbl Other

For data sources see[6]

Inspection Data

Inspections Performed

Inspection ID Inspection Category Inspection Date Inspection Type Inspection Result Inspection Comments
2779903 Primary Facility 2018-09-26 Routine/Complete Inspection No Violations Noted This well is tagged and in production. The annulus is shut.

NOTE: The well head is showing severe corrosion and will need some attention in the near future in order to prevent leakage and potential loss of mechanical integrity. (See attached photos.) I am asking for a call after the corrosion issue on this well has been addressed. I am coding this well NOVIO at this time, BUT, if the well head corrosion issue is not addressed before it gets worse, this coding will likely change.

The rest of the well head piping, equipment and small fluid collection tank look ok.

For data sources see[7]

References