{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.94,"lon":-81.64,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: <County> | |
Municipality: | |
Operator Name: DOMINION EAST OHIO | |
Well Pad ID: | |
Farm/Lease Name: BLAZ | |
License Status: Storage Well | |
License Date: 2014-03-05 | |
Spud Date: 2012-11-19 | |
Spud Drilling Contractor: WHIPSTOCK OHIO DRILLING | |
Final Drill Date: 2012-11-25 | |
Well Total Depth: 4384.00 ft | |
Configuration: Directional | |
Latitude: 40.940000 | |
Longitude: -81.640000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
APP | 2012-10-24 | Proposed Formations:CLINTON, Issued Date:10/24/2012, Expired Date:10/24/2014 12:00:00 PM, Drilling unit acres:80, Proposed Well Type:OG, Proposed Well Class:POOL |
Reached Total Depth | 2012-11-25 | |
APP | 2012-12-11 | Proposed Formations:CLINTON, Issued Date:12/11/2012, Expired Date:12/11/2014 12:00:00 PM, Drilling unit acres:-9, Proposed Well Type:OG, Proposed Well Class:POOL |
Completion Report Received | 2013-03-15 | |
Correction to Well | 2013-04-05 | CORRECTION TO TARGET INFORMATION: FOOTAGE & X,Y COORDINATES FROM AS DRILLED SURVEY PLAT. |
Change of Owner | 2014-02-20 | Operator changed from 8632, DOMINION FIELD SERVICES INC to 240, DOMINION EAST OHIO |
APP | 2014-03-05 | Proposed Formations:CLINTON, Issued Date:3/5/2014, Expired Date:3/4/2016 12:00:00 PM, Drilling unit acres:0, Proposed Well Type:SO, Proposed Well Class: |
Construction Permit Expires | 2015-03-05 | |
Record Last Modified | 2015-09-24 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2013-03-19 | 4174 | 4228 | 41 |
4174 | 4228 | 41 | |
4174 | 4228 | 41 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
2013-01-25 | H2O | 15 | 1530 Bbl | 60000 | Universal Well Services Inc. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | DOMINION FIELD SERVICES INC | 5217.00 | 264.00 | 235 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | DOMINION FIELD SERVICES INC | Brine | 192 | 235 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-124997813 | 2015-1-28 0:00: | SO | No Violations | 0.50 |
-1661232615 | 2018-1-17 0:00: | SO | No Violations | |
-184295459 | 2013-4-10 0:00: | DD | No Violations | 1.00 |
-330229272 | 2017-1-11 0:00: | SO | No Violations | |
-535287783 | 2016-3-21 0:00: | SO | No Violations | |
-641069938 | 2020-3-25 0:00: | SO | No Violations | |
0124997813 | 2015-01-28 | Storage Well | No Violations | This gas storage well has no apparent problems at this time. |
0184295459 | 2013-04-10 | Drill / Deepen / Reopen | No Violations | Site remains in same condition as on March 15, 2013 when tanks caught fire. Spoke with Mark Richardson, and Dominion is still investigating the incident. Mark will send me the report once investigation is complete, and will notify me when theyll be replacing tanks, ladders, etc. in the tank battery. As of this date, preliminary restoration is not complete. |
0330229272 | 2017-01-11 | Storage Well | No Violations | Performed annual inspection for Dominion East Ohios Storage Well #4101 on 01/11/2017. The tank battery consists of 2-100 bbl steel tanks, 1-1,550 gal plastic tank, 1-horizontal separator, and 2-vertical separators, located within an earthen dike; the diked area is located within a locked metal fence. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is a rabbit well, located within a locked metal fence. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
0535287783 | 2016-03-21 | Storage Well | No Violations | Inspected Dominion East Ohio Storage Well #4101 on 03/21/2016. The tank battery consists of 2-100 bbl steel tanks, 1-2,100 gal plastic tank, 1-horizontal separator, and 2-vertical separators within an earthen dike. The diked area is located within a locked metal fence. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is a rabbit well, located within a locked metal fence. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
1363619865 | 2013-03-15 | Production Wells | No Violations | Received phone call from Deputy Chief Claus concerning an oil tank fire in Chippewa Township, Wayne County. Investigation revealed fire to be on the Blaz 1-D lease, owned by Dominion East Ohio Gas. Upon my arrival, fire had been extinguished and there was no evidence of any enviromental impact. Met with Mark Richardson, Dominion Supervisor, and he has made arrangements to have unburnt fluid in both tanks removed immediately. Follow up call with Mark on Monday the 18th revealed they steamed the tanks out on Saturday morning, and are having special investigators come in to try to determine a definitive cause for the fire. Once the internal investigation is finished, all equipment from the tank battery will be removed and new installed. Mark is to let me know when the investigators will be on site, and when the new equipment will be installed. |
1368013623 | 2013-05-08 | Production Wells | No Violations | The tanks from the fire have been replaced with 2 140 barrel tanks. New ladders and walkways in place. Location still in need of preliminary restoration. Mark Richardson says the investigation into the fire is still ongoing. |
1376049938 | 2013-08-09 | Production Wells | No Violations | Went to this well to confirm GPS coordinates, as the site is not on the DeLorme mapping system. E-mail to Steve Opritza with pertinent information. |
1416584558 | 2014-11-07 | Storage Well | No Violations | Complaint 4854: Landowner concerned about lack of culvert pipe on lease road. Per permit conditions culvert pipe to be installed wherever needed to facilitate drainage. Contact DEOG, Phil Vrbasnik. See complaint for complete details. |
1492749667 | 2014-12-02 | Production Wells | No Violations | Received call from Phil Vrbasnik. Culvert pipe installed. Contacted complainant and inspected culvert. Landowner is content with procedure and results. Complaint #4854 is closed. |
1502084553 | 2017-01-11 | Preliminary Restoration | No Violations | Inspected storage well on 01/11/2017. All drilling equipment and debris has been removed, pits closed, and the well placed into production. Preliminary restoration passes. |
1632098472 | 2014-11-21 | Storage Well | No Violations | No issues at this time. |
1661232615 | 2018-01-17 | Storage Well | No Violations | Performed annual inspection for Dominion East Ohio Storage Well #4101 on 01/17/2018. The tank battery consists of 2-100 bbl steel tanks, 1-1,550 gal plastic tank, 1-horizontal separator with a master meter, 2-vertical separators with 2-drips and 2-meter boxes, located within an earthen dike; the diked area is located within a locked metal fence with vinyl privacy inserts. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is a rabbit well, located within a locked metal fence with vinyl privacy inserts. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |
1796314400 | 2013-07-12 | Preliminary Restoration | No Violations | Meets requirements for preliminary restoration. Location needs added to mapping system, and status changed to producing well. |
2051359530 | 2019-01-24 | Storage Well | No Violations | Performed annual inspection for Dominion East Ohio Storage Well #4101 on 01/24/2019. The tank battery consists of 2-100 bbl steel tanks, 1-1,550 gal plastic tank, 2-vertical separators with 2-drips and 2-meter boxes, and 1-horizontal separator with a master meter, located within an earthen dike; the diked area is located within a locked metal fence with vinyl privacy inserts. The tank battery is used by multiple wells (2); well identification is clearly displayed for all wells utilizing it. The well is a rabbit well, located within a locked metal fence with vinyl privacy inserts. Well identification is posted at the wellhead as required. No problems were noted at the time of the inspection. |