34-167-29485

Well Details

Well ID: 34-167-29485
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Warren Township
Operator Name: HEINRICH ENTERPRISES INC DBA W
Well Pad ID:
Farm/Lease Name: CRAIG R # 2-SH117
License Status: Producing
License Date: 2000-11-09
Spud Date: 2000-12-04
Spud Drilling Contractor: WARREN DRLG
Final Drill Date: 2000-12-10
Well Total Depth: 6447.00 ft
Configuration: Vertical
Latitude: 39.420000
Longitude: -81.520000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2000-11-09 3793 ENERGY SEARCH INC Proposed Formation CLINTON AND MEDINA Issued Date 11/9/00 Expired Date 11/9/01 6:00:00 AM
Correction to Well 2000-11-17 ADDED FOOTAGE DESCRIPTION: 920'SL & 885'EL OF SEC. 18; CHANGE IN WELL NUMBER TO 2-SH117.
Original Spud 2000-12-04 RBDMS Rec
Completed 2000-12-10 RBDMS Rec
Reached Total Depth 2000-12-10 RBDMS Rec
Completion Report Received 2001-04-02 RBDMS Rec
Construction Permit Expires 2001-11-09 RBDMS Rec
Change of Owner 2008-02-27 Operator changed from 3793, ENERGY SEARCH INC to 1388, NORTH COAST ENERGY INC
Change of Owner 2009-12-14 Operator changed from 1388, EXCO - NORTH COAST ENERGY INC to 7578, ENERVEST OPERATING LLC
Change of Owner 2015-11-04 Operator changed from 7578, ENERVEST OPERATING LLC to 2007, HEINRICH ENT INC/WASHINGTON OP
Record Last Modified 2015-11-04 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2001-06-06 6190 6305 49
6190 6305 49
6190 6305 49

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1559 Bbl 46000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2000 ENERGY SEARCH INC 420.00 0.00 0
2001 ENERGY SEARCH INC 5017.00 0.00 365
2002 ENERGY SEARCH INC 3396.00 0.00 365
2003 ENERGY SEARCH INC 2349.00 0.00 365
2004 ENERGY SEARCH INC 2520.00 0.00 365
2005 ENERGY SEARCH INC 1486.00 0.00 365
2006 ENERGY SEARCH INC 1381.00 0.00 365
2007 ENERGY SEARCH INC 1268.00 0.00 365
2008 EXCO - NORTH COAST ENERGY INC 1472.00 0.00 366
2009 EXCO - NORTH COAST ENERGY INC 1178.00 0.00 365
2010 ENERVEST OPERATING LLC 1043.00 0.00 365
2011 ENERVEST OPERATING LLC 1227.00 0.00 0
2012 ENERVEST OPERATING LLC 1055.00 0.00 366
2013 ENERVEST OPERATING LLC 1090.00 0.00 365
2014 ENERVEST OPERATING LLC 774.00 0.00 365
2015 ENERVEST OPERATING LLC 346.00 0.00 243
2016 HEINRICH ENTERPRISES INC DBA W 0.00 0.00 365
2017 HEINRICH ENTERPRISES INC DBA W 0.00 0.00 365
2018 HEINRICH ENTERPRISES INC DBA W 0.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2000 ENERGY SEARCH INC Brine
2001 ENERGY SEARCH INC Brine 221 365
2002 ENERGY SEARCH INC Brine 365
2003 ENERGY SEARCH INC Brine 365
2004 ENERGY SEARCH INC Brine 82 365
2005 ENERGY SEARCH INC Brine 0 365
2006 ENERGY SEARCH INC Brine 0 365
2007 ENERGY SEARCH INC Brine 0 365
2008 EXCO - NORTH COAST ENERGY INC Brine 145 366
2009 EXCO - NORTH COAST ENERGY INC Brine 0 365
2010 ENERVEST OPERATING LLC Brine 61 365
2011 ENERVEST OPERATING LLC Brine 17
2012 ENERVEST OPERATING LLC Brine 0 366
2013 ENERVEST OPERATING LLC Brine 0 365
2014 ENERVEST OPERATING LLC Brine 0 365
2015 ENERVEST OPERATING LLC Brine 68 243
2016 HEINRICH ENTERPRISES INC DBA W Brine 777 365
2017 HEINRICH ENTERPRISES INC DBA W Brine 0 365
2018 HEINRICH ENTERPRISES INC DBA W Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1258197731 2017-2-7 0:00:0 AM No Violations 0.50
-157185155 2017-2-7 0:00:0 PW No Violations
-1683264804 2017-1-3 0:00:0 AM No Violations 0.30
-1691642928 2018-3-1 0:00:0 PW No Violations
-1798512392 2002-1-2 0:00:0 PL No Violations
-373932950 2017-1-3 0:00:0 AM No Violations 0.30
-407379800 2017-1-4 0:00:0 AM No Violations 0.40
-785814135 2017-1-4 0:00:0 AM No Violations 0.50
-903647059 2017-1-3 0:00:0 AM No Violations 0.30
0157185155 2017-02-07 Production Wells No Violations I went to the release location to inspect the remediation efforts today. There was a bulldozer at the end of the lease road. When I arrived at the location there was a backhoe sitting below the dike. Nobody was at the location working on the cleanup today. They removed dirt below the dike and removed dirt and grass in the area affected by the scald to the dead evergreen tree. Inspection of the well found fluid to be seeping out from the threads on the tubing head. There was also gas leaking out around the bull plug on the 8.625 inch diameter casing head. I notified Sam Johnson of my findings at the well.
0373932950 2017-01-03 Administrative Inspection No Violations Sam called me back after checking his notes to give me more specific dates. He said the spill happened on the afternoon of June 17th. The water was hauled by them on the 20th to their injection well from the Craig well. This was to verify an earlier statement and to acquire specific dates.
0407379800 2017-01-04 Administrative Inspection No Violations Brian Chavez returned my call from the day before to talk about the notice on this well. He asked for more time because of the weather and the fact that the land owner leases the ground for hunting. I explained I would have to call him back with a definitive answer.
0785814135 2017-01-04 Administrative Inspection No Violations I tried to call Brian back but only got a fax machine ring. I then called Sam Johnson back and explained that they would need to put their request for an extension in writing with the reasons and the plan of action for completing the work. I also explained that the pit on the vocational well will need closed in and that a notice would be issued. I also told Sam that the Sullivan well was leaking around the bull plug and that it would need to be tightened to prevent the escape of gas.
0903647059 2017-01-03 Administrative Inspection No Violations I called Sam Johnson who said the water was hauled to their WES injection well with their own trucks. He was not able to guess at the amount of brine that was lost outside of the dike. He said he could look and tell me the date the spill was noticed and the brine was hauled from the tank. He also stated he miss spoke when he said the area was seeded and mulched, He corrected the statement and said it fertilized and seeded.
1258197731 2017-02-07 Administrative Inspection No Violations Sam Johnson returned my call. I left a voicemail earlier to inquire about where the contaminated soil was going from this well. Sam called me back with the coordinates and explained that it was near their compressor station straight back the lease road from the intersection of Shay rd. and Twp. Rd 34. He also added that it was near well API # 22913. He stated that it was in a lined pit.
1297511758 2016-12-22 Production Wells No Violations I was accompannied by Supervisor Eric Conrad who was conducting a ride along with me. Inspection of this well brought me to the tank battery first. The identification at the tank battery was not correct or filled out properly. The tank battery was comprised of a 210 barrel steel tank with no plugs in the top of the tank, meter and a separator. The dike drain was open at the end and the cap that was on the end was unscrewed. There was a very significant and large scald area out side the dike. That using my gps I concluded was about 75 feet wide and traveled 250 feet downhill. There were at least 4 cedar trees in the affected area 3 of these trees that were closer to the source were heavily distressed. The production tubing in the well was shut in and disconnected. The 4 1/2 inch diameter pipe was leaking around the top of the tubing head no gas was detected and it was just clear fluid. A field test with Quantabs maxed out the low strips indicating at least 600 ppm chlorides. The 8 inch diameter casing was leaking below the casing head. These two leaks were causing pollution and contamination around the well head. Further investigation will be needed to deduce why the 4 1/2 inch diameter and 8 inch diameter were full of brine causing the casing heads to leak. When we returned to the truck Sam Johnson, Productin Manager for Condevco Washington Operations, pulled up. He addmitted that the tank over ran back in June or July. He said that he tried to call Andy Thomas but the number was wrong. He said that they seeded and mulched the area then. All contaminated soil will be removed and taken to an epa approved landfill. Noncontaminated soil will be brought in to replace the contaminated soil removed. All affected areas will be seeded and mulched to allow vegetaion to reestablish to prevent erosion. The dike drain shall be made to prevent the escape of fluids. The tank battery shall be properly identified with the Company name and telephone as well as the other required inf
1484920617 2016-01-17 Administrative Inspection No Violations On January 13, 2017, I received a written request from Heinrich Enterprises requesting an extension to complete work on the well site. On January 18, 2017, I mailed a written response to Heinrich Enterprises offering them an extension until February 20, 2017 to complete all work on the site.
1599743280 2018-02-12 Production Wells No Violations This well was issued a compliance notice from Inspector Matt Fulk for well operation causing pollution and contamination, well sufficiently equipped to prevent the escape of oil and gas, failure to legibly identify well, dike or pit not able to prevent escape of brine or other wastes, and defective casing, leaking well. The inspection this day revealed that this well is equipped with 8 5/9 inch diameter surface and a 4 1/2 inch diameter production casing. The valves on the wellhead are closed but the well is equipped in a manner for production. The areas mentioned by Inspector Matt Fulk in his reports have been cleaned up and there are no signs of any contamination or spill. The wellhead is equipped and repaired in a way that there is no fluid actively leaking from the well. There is proper identification on the wellhead and the tank battery. The tank battery is equipped with a 210 barrel steel tank and a vertical separator. There is a proper earthen dike built around the tank. There are no signs of the original pollution and contamination, the well is properly identified, and the leak has been repaired on the well. This well is now in compliance.
1683264804 2017-01-03 Administrative Inspection No Violations Called Heinrich Inc, spoke with receptionist and asked to talk to someone who could answer questions concerning the Craig well I issued a compliance notice for. She stated that Brian Chavez wasnt in and would not be in till tomorrow and that this was indeed the best number to reach him at. She then gave me Sam Johnsons cell number. I called Sam Johnson to get some information about when the spill occurred and if brine was hauled from the location.
1691642928 2018-03-01 Production Wells No Violations Inspector Brian Sefcik asked me to close out this violation on my side since he has passed it.
1798512392 2002-01-02 Preliminary Restoration No Violations

For data sources see[9]

References