X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-167-25482

Well Details

Well ID: 34-167-25482
Loading map...
Country: United States
State: Ohio
County: Washington
Municipality: Belpre Township
Operator Name: WILSON ENERGY LLC
Well Pad ID:
Farm/Lease Name: OXBOW DEVELOPMENT
License Status: Producing
License Date: 1981-06-01
Spud Date: 1980-05-14
Spud Drilling Contractor:
Final Drill Date: 1980-05-20
Well Total Depth: 2099.00 ft
Configuration: Vertical
Latitude: 39.310000
Longitude: -81.630000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1980-05-14
Completed 1980-05-20
Reached Total Depth 1980-05-20
CO 1981-06-01 2202 DECKER WELL SERVICE GeoDate 6/1/81
Change of Owner 2013-02-05 Operator changed from 2202, DECKER WELL SERVICE to 8355, WILSON ENERGY LLC
Record Last Modified 2013-10-03

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 1982 1988 5
1982 1988 5
1982 1988 5

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 54000 Gal 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 COLUMBIA GAS TRANSMISSION LLC 2404.00 0.00 0
1985 DECKER WELL SERVICE LLC 3008.00 65.00 335
1986 DECKER WELL SERVICE LLC 2478.00 0.00 330
1987 DECKER WELL SERVICE LLC 2425.00 0.00 365
1988 DECKER WELL SERVICE LLC 2177.00 0.00 365
1989 DECKER WELL SERVICE LLC 1762.00 0.00 365
1990 DECKER WELL SERVICE LLC 1811.00 0.00 365
1991 DECKER WELL SERVICE LLC 2111.00 0.00 365
1992 DECKER WELL SERVICE LLC 1078.00 0.00 365
1993 DECKER WELL SERVICE LLC 621.00 9.00 365
1994 DECKER WELL SERVICE LLC 750.00 0.00 365
1995 DECKER WELL SERVICE LLC 985.00 0.00 365
1996 DECKER WELL SERVICE LLC 1461.00 0.00 365
1997 DECKER WELL SERVICE LLC 1209.00 0.00 365
1998 DECKER WELL SERVICE LLC 787.00 0.00 365
1999 DECKER WELL SERVICE LLC 889.00 0.00 365
2000 DECKER WELL SERVICE LLC 704.00 0.00 365
2001 DECKER WELL SERVICE LLC 518.00 0.00 365
2002 DECKER WELL SERVICE LLC 639.00 0.00 365
2003 DECKER WELL SERVICE LLC 524.00 0.00 365
2004 DECKER WELL SERVICE LLC 302.00 0.00 365
2005 DECKER WELL SERVICE LLC 246.00 0.00 365
2006 DECKER WELL SERVICE LLC 226.00 0.00 365
2007 DECKER WELL SERVICE LLC 333.00 0.00 365
2008 DECKER WELL SERVICE LLC 203.00 0.00 365
2009 DECKER WELL SERVICE LLC 580.00 0.00 365
2010 DECKER WELL SERVICE LLC 457.00 0.00 365
2011 DECKER WELL SERVICE LLC 385.00 0.00 365
2012 DECKER WELL SERVICE LLC 427.00 37.00 366
2013 WILSON ENERGY LLC 295.00 0.00 365
2014 WILSON ENERGY LLC 286.00 0.00 297
2015 WILSON ENERGY LLC 344.00 0.00 365
2016 WILSON ENERGY LLC 547.00 0.00 365
2017 WILSON ENERGY LLC 469.00 0.00 365
2018 WILSON ENERGY LLC 433.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 COLUMBIA GAS TRANSMISSION LLC Brine 0 0
1985 DECKER WELL SERVICE LLC Brine 1 335
1986 DECKER WELL SERVICE LLC Brine 0 330
1987 DECKER WELL SERVICE LLC Brine 0 365
1988 DECKER WELL SERVICE LLC Brine 0 365
1989 DECKER WELL SERVICE LLC Brine 0 365
1990 DECKER WELL SERVICE LLC Brine 0 365
1991 DECKER WELL SERVICE LLC Brine 0 365
1992 DECKER WELL SERVICE LLC Brine 0 365
1993 DECKER WELL SERVICE LLC Brine 10 365
1994 DECKER WELL SERVICE LLC Brine 0 365
1995 DECKER WELL SERVICE LLC Brine 0 365
1996 DECKER WELL SERVICE LLC Brine 0 365
1997 DECKER WELL SERVICE LLC Brine 0 365
1998 DECKER WELL SERVICE LLC Brine 0 365
1999 DECKER WELL SERVICE LLC Brine 0 365
2000 DECKER WELL SERVICE LLC Brine 0 365
2001 DECKER WELL SERVICE LLC Brine 0 365
2002 DECKER WELL SERVICE LLC Brine 0 365
2003 DECKER WELL SERVICE LLC Brine 0 365
2004 DECKER WELL SERVICE LLC Brine 0 365
2005 DECKER WELL SERVICE LLC Brine 0 365
2006 DECKER WELL SERVICE LLC Brine 0 365
2007 DECKER WELL SERVICE LLC Brine 0 365
2008 DECKER WELL SERVICE LLC Brine 0 365
2009 DECKER WELL SERVICE LLC Brine 0 365
2010 DECKER WELL SERVICE LLC Brine 0 365
2011 DECKER WELL SERVICE LLC Brine 0 365
2012 DECKER WELL SERVICE LLC Brine 0 366
2013 WILSON ENERGY LLC Brine 0 365
2014 WILSON ENERGY LLC Brine 0 297
2015 WILSON ENERGY LLC Brine 0 365
2016 WILSON ENERGY LLC Brine 0 365
2017 WILSON ENERGY LLC Brine 0 365
2018 WILSON ENERGY LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0290457660 2015-10-07 Production Wells Violations Noted Upon inspection, it was observed that this well is currently in production. The well consists of 8.625 surface casing, 4.5 production casing, and 1.5 production tubing. The well is producing sales on the 1.5 tubing. There is a mechanical separator, drip, and meter run near the well. The tank battery consists of a 100 bbl production tank and containment dike. Legible and correct ID is posted on the tank. The bottom weld of the tank has rusted through and allowed oily sludge to leak out of the tank and onto the tank pad. Free oil seeped through the southern dike wall and began to run downhill away from the location. The amount of release is less than 10 gallons. I contacted Mr. Bob Wilson via phone call and told him to remove the leaking tank and excavate any contaminated soil in the tank pad, dike wall, and outside the dike. Mr. Wilson stated he would have the mess cleaned up and the tank removed this afternoon. He also stated he will set a smaller tank since the well does not make much fluid. Wilson Energy will have until 10/14/2015 to have the tank pad location remediated.
0322378103 2015-10-08 Production Wells No Violations Upon inspection, it was observed that the contaminated soil has been excavated from the tank pad, dike wall, and area outside the dike wall. The affected area has been limed, seeded, and mulched. The leaking 100 bbl production tank has been removed and a temporary swab tank has been put in place until a 2100 gallon plastic tank can be placed on the tank pad. The dike wall has been rebuilt and is satisfactory. This satisfies the conditions of the compliance notice dated 10/8/2015.
1185440405 2005-09-06 Production Wells No Violations Inspection this day found well producing with rabbit?, tank has good IDs, good dike, current chart in meter.
2020699918 2015-10-08 Administrative Inspection No Violations Received call from Bob Wilson at 9:06 am stating the leaking 100 bbl tank has been removed, oily soil has been excavated and disposed of, and the affected area has been limed, seeded, and mulched. I will check on this location to verify that these activities were performed. Mr. Wilson stated that a new tank will be installed next week.
290457660 2015-10-7 0:00: PW No Violations 1.00
322378103 2015-10-8 0:00: PW No Violations 2.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0290457660 US-OH-123014 2015-10-13 Well operation causing pollution and contamination
0290457660 US-OH-123015 2015-10-13 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]

References