X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-157-22014

Well Details

Well ID: 34-157-22014
Loading map...
Country: United States
State: Ohio
County: Tuscarawas
Municipality: Clay Township
Operator Name: BOWER OIL & GAS LLC
Well Pad ID:
Farm/Lease Name: WILSON UNIT
License Status: Producing
License Date: 1975-05-12
Spud Date: 1975-06-14
Spud Drilling Contractor:
Final Drill Date: 1975-06-25
Well Total Depth: 5007.00 ft
Configuration: Vertical
Latitude: 40.310000
Longitude: -81.470000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1975-05-12 311 STOCKER & SITLER INC GeoDate 5/12/75
Original Spud 1975-06-14 RE-ISS., REV. LOC., CH. WELL # 5-14-75
Completed 1975-06-25 RE-ISS., REV. LOC., CH. WELL # 5-14-75
Reached Total Depth 1975-06-25 RE-ISS., REV. LOC., CH. WELL # 5-14-75
Change of Owner 1999-11-02 Operator changed from 311, STOCKER & SITLER INC to 6295, KNOX ENERGY INC.
Record Last Modified 2019-06-04 RE-ISS., REV. LOC., CH. WELL # 5-14-75

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4816 4837 15
4816 4837 15
4816 4837 15

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 2150 Bbl 70000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 STOCKER & SITLER INC 8740.00 0.00 365
1985 STOCKER & SITLER INC 6817.00 0.00 0
1986 STOCKER & SITLER INC 1725.00 0.00 365
1987 STOCKER & SITLER INC 7644.00 0.00 365
1988 STOCKER & SITLER INC 1671.00 0.00 0
1989 STOCKER & SITLER INC 1922.00 86.00 365
1990 STOCKER & SITLER INC 2915.00 86.00 365
1991 STOCKER & SITLER INC 2769.00 0.00 365
1992 STOCKER & SITLER INC 2404.00 0.00 365
1993 STOCKER & SITLER INC 2008.00 0.00 365
1994 STOCKER & SITLER INC 1624.00 0.00 0
1995 STOCKER & SITLER INC 2047.00 0.00 0
1996 STOCKER & SITLER INC 1633.00 0.00 0
1997 STOCKER & SITLER INC 1273.00 0.00 365
1998 STOCKER & SITLER INC 1105.00 0.00 365
1999 STOCKER & SITLER INC 1731.00 0.00 365
2000 KNOX ENERGY INC. 1829.00 0.00 365
2001 KNOX ENERGY INC. 1606.00 0.00 365
2002 KNOX ENERGY INC. 0.00 0.00 365
2003 KNOX ENERGY INC. 1501.00 0.00 365
2004 KNOX ENERGY INC. 1619.00 0.00 366
2005 KNOX ENERGY INC. 2150.00 0.00 365
2006 KNOX ENERGY INC. 2921.00 0.00 365
2007 KNOX ENERGY INC. 2484.00 0.00 365
2008 KNOX ENERGY INC. 2383.00 0.00 365
2009 KNOX ENERGY INC. 2146.00 136.00 365
2010 KNOX ENERGY INC. 1722.00 0.00 365
2011 KNOX ENERGY INC. 1384.00 0.00 365
2012 KNOX ENERGY INC. 1526.00 0.00 366
2013 KNOX ENERGY INC. 1484.00 0.00 365
2014 KNOX ENERGY INC. 1259.00 0.00 365
2015 KNOX ENERGY INC. 1175.00 0.00 365
2016 KNOX ENERGY INC. 1255.00 0.00 365
2017 KNOX ENERGY INC. 1381.00 0.00 365
2018 KNOX ENERGY INC. 1184.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 STOCKER & SITLER INC Brine 0 365
1985 STOCKER & SITLER INC Brine 0 0
1986 STOCKER & SITLER INC Brine 0 365
1987 STOCKER & SITLER INC Brine 0 365
1988 STOCKER & SITLER INC Brine 0 0
1989 STOCKER & SITLER INC Brine 0 365
1990 STOCKER & SITLER INC Brine 0 365
1991 STOCKER & SITLER INC Brine 0 365
1992 STOCKER & SITLER INC Brine 0 365
1993 STOCKER & SITLER INC Brine 0 365
1994 STOCKER & SITLER INC Brine 0 0
1995 STOCKER & SITLER INC Brine 0 0
1996 STOCKER & SITLER INC Brine 0 0
1997 STOCKER & SITLER INC Brine 0 365
1998 STOCKER & SITLER INC Brine 0 365
1999 STOCKER & SITLER INC Brine 0 365
2000 KNOX ENERGY INC. Brine 0 365
2001 KNOX ENERGY INC. Brine 0 365
2002 KNOX ENERGY INC. Brine 0 365
2003 KNOX ENERGY INC. Brine 0 365
2004 KNOX ENERGY INC. Brine 0 366
2005 KNOX ENERGY INC. Brine 0 365
2006 KNOX ENERGY INC. Brine 0 365
2007 KNOX ENERGY INC. Brine 0 365
2008 KNOX ENERGY INC. Brine 0 365
2009 KNOX ENERGY INC. Brine 0 365
2010 KNOX ENERGY INC. Brine 0 365
2011 KNOX ENERGY INC. Brine 0 365
2012 KNOX ENERGY INC. Brine 0 366
2013 KNOX ENERGY INC. Brine 0 365
2014 KNOX ENERGY INC. Brine 0 365
2015 KNOX ENERGY INC. Brine 0 365
2016 KNOX ENERGY INC. Brine 0 365
2017 KNOX ENERGY INC. Brine 0 365
2018 KNOX ENERGY INC. Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1320374808 2004-11-5 0:00: PL No Violations
-1578372649 2018-12-26 0:00 PW No Violations 0.60
-1791235607 2010-6-9 0:00:0 PW No Violations
1167287523 2004-11-05 Production Wells No Violations no violations dike ok
1277127304 2010-06-05 Production Wells No Violations on location for complaint of a gas odor,complaint came from EPA. Arrived at location and met with landowner who showed me where a 2 gas line is leaking. After doing some checking I found that knox energy owns well. I called knox and they sent out a well
1320374808 2004-11-05 Preliminary Restoration No Violations restoration ok
1426852116 2015-03-19 Production Wells No Violations On the day of my inspection I found a 4 X 1.5 inch wellhead operated by a plunger lift system. The valves are in the open position. The tank battery is made up of a one 100 bbl tank and a horizontal separator, all within an earthen dike. The tank is properly identified and the production reporting is up to date. The are no violations at this time.
1578372649 2018-12-26 Production Wells No Violations Upon arrival on location, I witnessed the well was equipped with 4.5 inch diameter casing, 1.5 inch diameter tubing, and a plunger lift system. The valves on tubing and on the casing were open. Domestic gas was being supplied off the 4.5 inch diameter casing. Production equipment included a steel 210 barrel tank, a steel 50 barrel tank and a horizonal separator within an earthen dike. The production report was up to date and proper identification was present.
1791235607 2010-06-09 Production Wells No Violations arrived on location and found crew repairing line leak, 1:00 pm violation was corrected line has been repaired and well turned back on.

For data sources see[9]

References