If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-157-21907 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.35,"lon":-81.36,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Tuscarawas | |
Municipality: Rush Township | |
Operator Name: HADDAD & BROOKS INC | |
Well Pad ID: | |
Farm/Lease Name: MCCAULEY | |
License Status: Final Restoration | |
License Date: 2017-11-22 | |
Spud Date: 1973-06-21 | |
Spud Drilling Contractor: | |
Final Drill Date: 1973-08-04 | |
Well Total Depth: 5316.00 ft | |
Configuration: Vertical | |
Latitude: 40.350000 | |
Longitude: -81.360000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1973-03-22 | 3552 PHOENIX NTL PETROLEUM CO GeoDate 3/22/73 |
Original Spud | 1973-06-21 | UPDATE LOCATION PER DOGRM SURVEYOR, ALE 2/12/18. |
Completed | 1973-08-04 | UPDATE LOCATION PER DOGRM SURVEYOR, ALE 2/12/18. |
Reached Total Depth | 1973-08-04 | UPDATE LOCATION PER DOGRM SURVEYOR, ALE 2/12/18. |
CO | 1991-11-20 | 395 HADDAD & BROOKS INC GeoDate 3/22/73 |
APP | 2017-11-22 | Proposed Formations:CLINTON, Issued Date:11/22/2017, Expired Date:11/22/2019 12:00:00 PM, Drilling unit acres:65.92, Proposed Well Type:OG, Proposed Well Class: |
Plugged/Abandoned | 2017-12-17 | UPDATE LOCATION PER DOGRM SURVEYOR, ALE 2/12/18. |
Record Last Modified | 2018-06-20 | UPDATE LOCATION PER DOGRM SURVEYOR, ALE 2/12/18. |
Construction Permit Expires | 2019-11-22 | UPDATE LOCATION PER DOGRM SURVEYOR, ALE 2/12/18. |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5135 | 5270 | 21 |
5135 | 5270 | 21 | |
5135 | 5270 | 21 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1900 Bbl | 40000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1997 | HADDAD & BROOKS INC | 2155.00 | 64.00 | 275 |
1998 | HADDAD & BROOKS INC | 2043.00 | 0.00 | 341 |
1999 | HADDAD & BROOKS INC | 1033.00 | 0.00 | 240 |
2000 | HADDAD & BROOKS INC | 3561.00 | 64.00 | 365 |
2001 | HADDAD & BROOKS INC | 2150.00 | 0.00 | 365 |
2002 | HADDAD & BROOKS INC | 2448.00 | 101.00 | 365 |
2003 | HADDAD & BROOKS INC | 2013.00 | 0.00 | 365 |
2004 | HADDAD & BROOKS INC | 1602.00 | 0.00 | 365 |
2005 | HADDAD & BROOKS INC | 1660.00 | 0.00 | 365 |
2006 | HADDAD & BROOKS INC | 2340.00 | 0.00 | 365 |
2007 | HADDAD & BROOKS INC | 3536.00 | 85.00 | 365 |
2008 | HADDAD & BROOKS INC | 2276.00 | 0.00 | 365 |
2009 | HADDAD & BROOKS INC | 2194.00 | 0.00 | 365 |
2010 | HADDAD & BROOKS INC | 3194.00 | 0.00 | 365 |
2011 | HADDAD & BROOKS INC | 2790.00 | 108.00 | 365 |
2012 | HADDAD & BROOKS INC | 2207.00 | 0.00 | 366 |
2013 | HADDAD & BROOKS INC | 2542.00 | 0.00 | 365 |
2014 | HADDAD & BROOKS INC | 1373.00 | 0.00 | 365 |
2015 | HADDAD & BROOKS INC | 950.00 | 0.00 | 365 |
2016 | HADDAD & BROOKS INC | 706.00 | 53.00 | 270 |
2017 | HADDAD & BROOKS INC | 127.00 | 0.00 | 270 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1997 | HADDAD & BROOKS INC | Brine | 0 | 275 |
1998 | HADDAD & BROOKS INC | Brine | 0 | 341 |
1999 | HADDAD & BROOKS INC | Brine | 0 | 240 |
2000 | HADDAD & BROOKS INC | Brine | 70 | 365 |
2001 | HADDAD & BROOKS INC | Brine | 0 | 365 |
2002 | HADDAD & BROOKS INC | Brine | 15 | 365 |
2003 | HADDAD & BROOKS INC | Brine | 0 | 365 |
2004 | HADDAD & BROOKS INC | Brine | 0 | 365 |
2005 | HADDAD & BROOKS INC | Brine | 0 | 365 |
2006 | HADDAD & BROOKS INC | Brine | 75 | 365 |
2007 | HADDAD & BROOKS INC | Brine | 170 | 365 |
2008 | HADDAD & BROOKS INC | Brine | 0 | 365 |
2009 | HADDAD & BROOKS INC | Brine | 92 | 365 |
2010 | HADDAD & BROOKS INC | Brine | 0 | 365 |
2011 | HADDAD & BROOKS INC | Brine | 62 | 365 |
2012 | HADDAD & BROOKS INC | Brine | 59 | 366 |
2013 | HADDAD & BROOKS INC | Brine | 0 | 365 |
2014 | HADDAD & BROOKS INC | Brine | 36 | 365 |
2015 | HADDAD & BROOKS INC | Brine | 0 | 365 |
2016 | HADDAD & BROOKS INC | Brine | 25 | 270 |
2017 | HADDAD & BROOKS INC | Brine | 0 | 270 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-57271040 | 2018-5-11 0:00: | FR | No Violations | 0.30 |
0057271040 | 2018-05-11 | Final Restoration | No Violations | On the day of inspection, I found that the final restoration inspection has been completed. The site passed final restoration according to ORC 1509.072 (B). |
0159289332 | 2017-12-11 | Plug / Plug Back | No Violations | Upon arrival on location I found the rig crew moving in and getting ready to start plugging the well. They were waiting on the service rig to arrive. They stated they would be ready to pump on the well Tuesday morning |
0425511164 | 2017-12-15 | Plug / Plug Back | No Violations | Nicks Well Plugging tripped 114 joints of 1.5 inch diameter tubing down to 3727 feet. A 300 foot big lime plug was set from 3427 feet to 3727 feet within the 7.875 inch diameter borehole. The plug consisted of 86 sacks of class A cement weighing 15.6 pounds per gallon with a yield of 1.18 cubic foot per sack. The plug was displaced with 8.5 barrels of fresh water. 75 joints of tubing were pulled to 1258 feet within the 7.875 inch diameter borehole, 100 feet below the 8.625 inch diameter surface casing. A 200 foot plug was pumped 100 foot within the 8.625 inch diameter surface casing and 100 foot within the 7.875 inch diameter borehole. The plug consisted of 61 sacks of class A cement weighing 15.6 pounds per gallon with a yield of 1.18 cubic foot per sack. The plug was displaced with 2.7 barrels of fresh water. The remaining 38 joints of 1.5 inch tubing were tripped out of hole. |
0478116813 | 2003-10-23 | Production Wells | No Violations | No violation |
0618773581 | 2017-12-18 | Plug / Plug Back | No Violations | Nicks Well Plugging tagged the top of the bottom of surface plug at 1060 feet. The plug remained at its required depth. Six joints of 1.5 inch diameter tubing were tripped into 200 feet below surface grade. A 200 foot plug was set to surface. The plug consisted of class A cement weighing 15.6 pounds per gallon with a yield of 1.18 cubic foot per sack. The remaining 6 joints of tubing were tripped out of the hole and the cement top was 4 foot from surface grade. The hole was topped off and the cement stayed at surface. A total of 81 sacks of cement were pumped for the surface plug. |
1513171844 | 2017-12-12 | Plug / Plug Back | No Violations | The purpose of my inspection was to witness plugging operations. This well was drilled to the Clinton Sands formation and was completed through 4.5 inch diameter casing with 21 perforations from 5135 feet to 5270 feet. The well was equipped with 8.625 inch diameter surface casing ran to 1158 feet, 4.5 inch diameter production casing ran to 5312, 1.5 inch diameter tubing, and a plunger lift system. 60 parts per million of Hydrogen Sulfide were detected at the wellhead. Appalachian Well Surveys, Nicks Well Plugging, Haddad and Brooks Incorporated, and Safety First were on location. Safety First set up a hydrogen sulfide monitoring system around the well location. Nicks Well Plugging nippled up to the 1.5 inch diameter tubing and attempted to pump through the tubing. The pump pressured up to 1000 pounds but could not pump through, confirming that there was a plunger still within the 1.5 inch diameter tubing. Appalachian Well Surveys rigged up and tripped in hole with a tubing cutter. The 1.5 inch diameter tubing was shot free at 5222 feet in depth. Appalachian Well Surveys tripped out of hole, rigged down, and exited the location. Nicks Well Plugging pumped a 400 foot plug through the 1.5 inch tubing a crossed the perforated portion of the 4.5 inch production casing from 5222 feet to 4822 feet in depth. The plug consisted of class A cement weighing 15.6 pound per gallon with a yield of 1.18. 12 barrels of fresh water were pumped for displacement. |
159289332 | 2017-12-11 0:00 | PB | No Violations | 2.50 |
2033634503 | 2017-12-13 | Plug / Plug Back | No Violations | Nicks Well Plugging blew down the 8.625 inch diameter surface casing and discovered high Hydrogen Sulfide readings up to 300 parts per million. The Safety First alarms went off and all personnel temporarily evacuated the wellsite until the gas pressure decreased and the hydrogen sulfide readings decreased. B and E Well Treating arrived on location with Sweetener to help kill the Hydrogen Sulfide Gas flow. 55 gallon of sweetener was mixed with 150 gallon of water and pumped down the well and the Hydrogen Sulfide gas flow was stopped. Nicks Well Plugging tipped within the 4.5 inch diameter casing with their ripping tool and ripped the 4.5 inch casing at 3735 feet, 248 feet below the top of the big lime. Nicks Well Plugging pulled up on the 4.5 inch casing and the block line began to break. The 4.5 inch casing was sat down and secured within the slips. Nicks Well Plugging made the necessary repairs to the rig. |
425511164 | 2017-12-15 0:00 | PB | No Violations | 9.00 |
478116813 | 2003-10-23 0:00 | PW | No Violations | |
618773581 | 2017-12-18 0:00 | PB | No Violations | 4.00 |
For data sources see[9]