34-157-21214

Well Details

Well ID: 34-157-21214
Loading map...
Country: United States
State: Ohio
County: Tuscarawas
Municipality: Salem Township
Operator Name: ARTH RICHARD E. & PATRICIA
Well Pad ID:
Farm/Lease Name: ARTH
License Status: Domestic Well
License Date: 2014-06-03
Spud Date: 1970-07-07
Spud Drilling Contractor:
Final Drill Date: 1970-08-15
Well Total Depth: 4731.00 ft
Configuration: Vertical
Latitude: 40.360000
Longitude: -81.570000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1970-07-07 REV. LOC. 7-2-70
Completed 1970-08-15 REV. LOC. 7-2-70
Reached Total Depth 1970-08-15 REV. LOC. 7-2-70
CO 1984-10-31 1146 ENNEY OILFIELD COMPANY
CO 1996-06-21 2409 RANDELL OIL CO GeoDate
Change of Owner 2013-02-20 Operator changed from 2409, RANDELL OIL CO to 201, GREEN GAS CO
APP 2014-06-03 Proposed Formations:CLINTON, Issued Date:6/3/2014, Expired Date:6/2/2016 12:00:00 PM, Drilling unit acres:91.62, Proposed Well Type:OG, Proposed Well Class:
Construction Permit Expires 2016-06-02 REV. LOC. 7-2-70
Record Last Modified 2017-02-15 REV. LOC. 7-2-70

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-06-22 4585 4645 13
4585 4645 13
4585 4645 13

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1575 Bbl 30000
H2O 0 1500 Bbl 35000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 SCION ENERGY INC 1895.00 0.00 0
1985 SCION ENERGY INC 1812.00 131.00 365
1986 SCION ENERGY INC 626.00 0.00 365
1987 SCION ENERGY INC 1334.00 0.00 365
1988 SCION ENERGY INC 1127.00 0.00 365
1989 SCION ENERGY INC 863.00 0.00 365
1990 SCION ENERGY INC 664.00 0.00 365
1991 SCION ENERGY INC 477.00 0.00 365
1992 SCION ENERGY INC 1740.00 0.00 365
1993 SCION ENERGY INC 1104.00 0.00 365
1994 SCION ENERGY INC 818.00 44.00 365
1995 SCION ENERGY INC 1167.00 9.00 365
1996 SCION ENERGY INC 274.00 0.00 243
1997 RANDELL OIL CO 1288.00 0.00 365
1998 RANDELL OIL CO 899.00 0.00 210
1999 RANDELL OIL CO 611.00 18.00 360
2000 RANDELL OIL CO 662.00 0.00 360
2001 RANDELL OIL CO 647.00 0.00 365
2002 RANDELL OIL CO 530.00 13.00 365
2003 RANDELL OIL CO 371.00 0.00 365
2004 RANDELL OIL CO 677.00 20.00 365
2005 RANDELL OIL CO 682.00 0.00 365
2006 RANDELL OIL CO 549.00 0.00 365
2007 RANDELL OIL CO 408.00 0.00 365
2008 RANDELL OIL CO 388.00 0.00 365
2009 RANDELL OIL CO 86.00 0.00 365
2010 RANDELL OIL CO 432.00 0.00 365
2011 RANDELL OIL CO 368.00 0.00 365
2012 RANDELL OIL CO 341.00 0.00 366
2013 GREEN GAS CO 13.00 0.00 365
2014 GREEN GAS CO 94.00 0.00 365
2016 GREEN GAS CO 0.00 0.00 0
2017 GREEN GAS CO 0.00 0.00 0
2018 GREEN GAS CO 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 SCION ENERGY INC Brine 0 0
1985 SCION ENERGY INC Brine 2 365
1986 SCION ENERGY INC Brine 0 365
1987 SCION ENERGY INC Brine 0 365
1988 SCION ENERGY INC Brine 0 365
1989 SCION ENERGY INC Brine 0 365
1990 SCION ENERGY INC Brine 0 365
1991 SCION ENERGY INC Brine 0 365
1992 SCION ENERGY INC Brine 0 365
1993 SCION ENERGY INC Brine 32 365
1994 SCION ENERGY INC Brine 23 365
1995 SCION ENERGY INC Brine 43 365
1996 SCION ENERGY INC Brine 13 243
1997 RANDELL OIL CO Brine 5 365
1998 RANDELL OIL CO Brine 0 210
1999 RANDELL OIL CO Brine 15 360
2000 RANDELL OIL CO Brine 0 360
2001 RANDELL OIL CO Brine 13 365
2002 RANDELL OIL CO Brine 7 365
2003 RANDELL OIL CO Brine 0 365
2004 RANDELL OIL CO Brine 18 365
2005 RANDELL OIL CO Brine 0 365
2006 RANDELL OIL CO Brine 0 365
2007 RANDELL OIL CO Brine 0 365
2008 RANDELL OIL CO Brine 0 365
2009 RANDELL OIL CO Brine 0 365
2010 RANDELL OIL CO Brine 0 365
2011 RANDELL OIL CO Brine 0 365
2012 RANDELL OIL CO Brine 0 366
2013 GREEN GAS CO Brine 0 365
2014 GREEN GAS CO Brine 0 365
2016 GREEN GAS CO Brine 0 0
2017 GREEN GAS CO Brine 0 0
2018 GREEN GAS CO Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1109510045 2014-4-24 0:00: PW No Violations 1.50
-1114289741 2020-9-29 0:00: EX No Violations 1.50
001252i379 2009-09-12 Production Wells No Violations no violations
0389854073 2016-11-02 Production Wells No Violations On the day of my inspection I found a 4 1/2 X 2 3/8 inch wellhead with 2 3/8 inch tubing and rods operated by pumping unit, with a gas motor. The valves are in the open position. The tank battery is made up of two 100 bbl. tanks, three horizontal separator, and two recording gauges. The tank is shared with well 34-157-2-1215 and 34-157-2-1197. The production reporting is not up to date, the tank is properly identified, and the last production was in the year of 2012. The well is supplying domestic gas.
1109510045 2014-04-24 Production Wells Violations Noted On the day of my inspection following up on NOV-1392211330, I witnessed that the well was equipped with 8.625 inch casing, 4.5 inch casing, 2.375 inch tubing rods and a pumping unit powered by natural gas. A 50bbl plastic tank and a 55 gallon drum containing oil not in containment were present near the well head. Contamination was present at the base of the tank. Production equipment included a 100bbl tank, a horizontal separator and a 2 inch sales meter with a .25 inch orifice and a chart recorder all shared with the Arth #3 34157212150000 and the Arth #1 34157212160000. All valves were closed at the well head. Call was made to Green Gas advising them of findings and requesting an update.
1252i379 2009-9-12 0:00: PW No Violations
1392211330 2014-01-13 Production Wells Violations Noted I arrived on this location and met with Mr Arth he is the landowner and complaintant. Mr Arth wants this well plugged and abandoned. This well has not produced in years. On 2/15/14 I talked with John Davis of Green Gas Company and he advised me that landowner would not let him on the well location to place well into production or to work over it. Within 180 days apply for a plug permit and make arrangements to plug well.
389854073 2016-11-2 0:00: PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1109510045 US-OH-102709 2016-07-26 9-9-05(A)1 Well insufficiently equipped to prevent escape of oil and gas
1109510045 US-OH-102710 2016-07-26 9-9-05(A)10 Failure to legibly identify well
1392211330 US-OH-111580 2014-02-27 Well shall be plugged

For data sources see[9]