34-157-21033

Well Details

Well ID: 34-157-21033
Loading map...
Country: United States
State: Ohio
County: Tuscarawas
Municipality: Warwick Township
Operator Name: PETROX, INC
Well Pad ID:
Farm/Lease Name: SCHWARK COMM #1
License Status: Producing
License Date: 1967-08-28
Spud Date: 1900-01-01
Spud Drilling Contractor:
Final Drill Date:
Well Total Depth:
Configuration: Vertical
Latitude: 40.420000
Longitude: -81.410000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1967-08-28 240 EAST OHIO GAS CO GeoDate 8/28/67
CO 1995-04-20 182 BELDEN & BLAKE CO GeoDate 8/28/67
Change of Owner 2002-08-12 Operator changed from 182, BELDEN & BLAKE CORPORATION to 1966, PETROX INC
Record Last Modified 2019-06-04 LOCATION INFO ADDED FROM 96 PROD TOWNSHIP ADDED WARWICK SECTION ADDED LOT ADDED

For data sources see[2]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1995 BELDEN & BLAKE CORPORATION 867.00 0.00 277
1996 BELDEN & BLAKE CORPORATION 1650.00 0.00 380
1997 BELDEN & BLAKE CORPORATION 1616.00 0.00 365
1998 BELDEN & BLAKE CORPORATION 1089.00 0.00 351
1999 BELDEN & BLAKE CORPORATION 931.00 0.00 365
2000 BELDEN & BLAKE CORPORATION 1278.00 0.00 331
2001 BELDEN & BLAKE CORPORATION 1669.00 0.00 346
2002 BELDEN & BLAKE CORPORATION 983.00 37.00 126
2003 PETROX, INC 1985.00 0.00 365
2004 PETROX, INC 1730.00 0.00 365
2005 PETROX, INC 1210.00 0.00 365
2006 PETROX, INC 1919.00 0.00 365
2007 PETROX, INC 1335.00 0.00 365
2008 PETROX, INC 940.00 0.00 365
2009 PETROX, INC 1017.00 0.00 365
2010 PETROX, INC 1047.00 0.00 365
2011 PETROX, INC 1000.00 0.00 365
2012 PETROX, INC 993.00 0.00 366
2013 PETROX, INC 1146.00 0.00 365
2014 PETROX, INC 838.00 0.00 365
2015 PETROX, INC 677.00 0.00 365
2016 PETROX, INC 372.00 0.00 365
2017 PETROX, INC 632.00 0.00 365
2018 PETROX, INC 780.00 0.00 365

For data sources see[3] [4]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1995 BELDEN & BLAKE CORPORATION Brine 0 277
1996 BELDEN & BLAKE CORPORATION Brine 14 380
1997 BELDEN & BLAKE CORPORATION Brine 0 365
1998 BELDEN & BLAKE CORPORATION Brine 0 351
1999 BELDEN & BLAKE CORPORATION Brine 0 365
2000 BELDEN & BLAKE CORPORATION Brine 0 331
2001 BELDEN & BLAKE CORPORATION Brine 0 346
2002 PETROX, INC Brine 0 365
2003 PETROX, INC Brine 0 365
2004 PETROX, INC Brine 0 365
2005 PETROX, INC Brine 0 365
2006 PETROX, INC Brine 0 365
2007 PETROX, INC Brine 365
2008 PETROX, INC Brine 0 365
2009 PETROX, INC Brine 0 365
2010 PETROX, INC Brine 0 365
2011 PETROX, INC Brine 0 365
2012 PETROX, INC Brine 0 366
2013 PETROX, INC Brine 0 365
2014 PETROX, INC Brine 0 365
2015 PETROX, INC Brine 0 365
2016 PETROX, INC Brine 0 365
2017 PETROX, INC Brine 0 365
2018 PETROX, INC Brine 0 365

For data sources see[5] [6]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1674988641 2018-9-14 0:00: PW No Violations 0.30
-183686679 2011-1-5 0:00:0 PW No Violations
0183686679 2011-01-05 Production Wells No Violations Check tank and wellsite found no violations at this time, The well is equipped with a swedge. Well is swabbed once or twice a year.
1502980094 2017-08-17 Production Wells No Violations On the day of my inspection I was accompanied by ODNR Inspector Randy Akins, we found the well equipped with 8 5/8 inch diameter casing, 4 1/2 inch diameter casing, 4 1/2 inch flange valve, 4 inch diameter cross with 3 inch diameter valve on the side, 3 1/2 x 2 3/8 inch diameter swage, and 2 3/8 inch valve. The production equipment is made up of one 100 bbl. steel tank, one vertical separator. The production reporting is up to date, and the tank is properly identified.
1502980820 2017-08-17 Production Wells No Violations On the day of my inspection I was accompanied by Inspector Tom Thomas, please refer to his inspection report.
1674988641 2018-09-14 Production Wells No Violations Upon arrival on location, I witnessed the well was equipped with 4.5 inch diameter casing, adapted with a 4.5 inch valve. The valve was in the open position. This is a swab well. Production equipment included a vertical separator, a steel 100 barrel tank, and a chart recorder with a 3 by .250 inch orifice plate. The production report was up to date and proper identification was present.

For data sources see[7]