If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-155-23500 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":41.27,"lon":-80.81,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Trumbull | |
Municipality: Howland Township | |
Operator Name: PIN OAK ENERGY PARTNERS LLC | |
Well Pad ID: | |
Farm/Lease Name: PATER | |
License Status: Producing | |
License Date: 1992-11-24 | |
Spud Date: 1992-12-15 | |
Spud Drilling Contractor: CUBBY DRLG | |
Final Drill Date: 1992-12-20 | |
Well Total Depth: 4594.00 ft | |
Configuration: Vertical | |
Latitude: 41.270000 | |
Longitude: -80.810000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
CO | 1992-11-24 | 2816 P & S ENERGY INC GeoDate 11/24/92 |
Oil and Gas | 1992-11-24 | Issued Date 11/24/92 Expired Date 11/24/93 Acres 0053170 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04594 Proposed Drill Depth 04594 |
Original Spud | 1992-12-15 | |
Completed | 1992-12-20 | |
Reached Total Depth | 1992-12-20 | |
Completion Report Received | 1993-01-04 | |
Construction Permit Expires | 1993-11-24 | |
Change of Owner | 2019-02-26 | Operator changed from 2816, P & S ENERGY INC to 9722, PIN OAK ENERGY PARTNERS LLC |
Record Last Modified | 2019-02-26 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 4329 | 4505 | 27 |
4326 | 4454 | 0 | |
1997-06-29 | 4326 | 4454 | 0 |
4329 | 4505 | 27 | |
4326 | 4454 | 0 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 78358 Gal | 80000 | FRAC W/78,358 GAL H20,800 SX SAND | ||
N2 | 0 | 230 Mscf | 0 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1992 | P & S ENERGY INC | 0.00 | 0.00 | 365 |
1993 | P & S ENERGY INC | 34694.00 | 294.00 | 255 |
1994 | P & S ENERGY INC | 33203.00 | 94.00 | 365 |
1995 | P & S ENERGY INC | 23550.00 | 108.00 | 365 |
1996 | P & S ENERGY INC | 20907.00 | 83.00 | 365 |
1997 | P & S ENERGY INC | 13337.00 | 0.00 | 365 |
1998 | P & S ENERGY INC | 10380.00 | 0.00 | 365 |
1999 | P & S ENERGY INC | 11557.00 | 0.00 | 365 |
2000 | P & S ENERGY INC | 11631.00 | 0.00 | 351 |
2001 | P & S ENERGY INC | 9569.00 | 66.00 | 316 |
2002 | P & S ENERGY INC | 8810.00 | 0.00 | 365 |
2003 | P & S ENERGY INC | 8052.00 | 0.00 | 365 |
2004 | P & S ENERGY INC | 6978.00 | 0.00 | 365 |
2005 | P & S ENERGY INC | 6147.00 | 0.00 | 365 |
2006 | P & S ENERGY INC | 6926.00 | 0.00 | 365 |
2007 | P & S ENERGY INC | 5351.00 | 0.00 | 365 |
2008 | P & S ENERGY INC | 5204.00 | 0.00 | 365 |
2009 | P & S ENERGY INC | 4925.00 | 0.00 | 365 |
2010 | P & S ENERGY INC | 5553.00 | 0.00 | 365 |
2011 | P & S ENERGY INC | 4916.00 | 0.00 | 365 |
2012 | P & S ENERGY INC | 4886.00 | 0.00 | 366 |
2013 | P & S ENERGY INC | 5889.00 | 0.00 | 365 |
2014 | P & S ENERGY INC | 5241.00 | 0.00 | 365 |
2015 | P & S ENERGY INC | 4190.00 | 0.00 | 365 |
2016 | P & S ENERGY INC | 2576.00 | 0.00 | 365 |
2017 | P & S ENERGY INC | 4315.00 | 0.00 | 365 |
2018 | P & S ENERGY INC | 3197.00 | 0.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1992 | P & S ENERGY INC | Brine | 1635 | 365 |
1993 | P & S ENERGY INC | Brine | 1505 | 255 |
1994 | P & S ENERGY INC | Brine | 70 | 365 |
1995 | P & S ENERGY INC | Brine | 0 | 365 |
1996 | P & S ENERGY INC | Brine | 0 | 365 |
1997 | P & S ENERGY INC | Brine | 0 | 365 |
1998 | P & S ENERGY INC | Brine | 0 | 365 |
1999 | P & S ENERGY INC | Brine | 0 | 365 |
2000 | P & S ENERGY INC | Brine | 0 | 351 |
2001 | P & S ENERGY INC | Brine | 0 | 316 |
2002 | P & S ENERGY INC | Brine | 0 | 365 |
2003 | P & S ENERGY INC | Brine | 0 | 365 |
2004 | P & S ENERGY INC | Brine | 0 | 365 |
2005 | P & S ENERGY INC | Brine | 0 | 365 |
2006 | P & S ENERGY INC | Brine | 0 | 365 |
2007 | P & S ENERGY INC | Brine | 0 | 365 |
2008 | P & S ENERGY INC | Brine | 0 | 365 |
2009 | P & S ENERGY INC | Brine | 0 | 365 |
2010 | P & S ENERGY INC | Brine | 0 | 365 |
2011 | P & S ENERGY INC | Brine | 70 | 365 |
2012 | P & S ENERGY INC | Brine | 0 | 366 |
2013 | P & S ENERGY INC | Brine | 0 | 365 |
2014 | P & S ENERGY INC | Brine | 0 | 365 |
2015 | P & S ENERGY INC | Brine | 0 | 365 |
2016 | P & S ENERGY INC | Brine | 32 | 365 |
2017 | P & S ENERGY INC | Brine | 0 | 365 |
2018 | P & S ENERGY INC | Brine | 0 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1533815873 | 2020-6-9 0:00:0 | UP | No Violations | |
0000013503 | Preliminary Restoration | No Violations | PASSED Y WITNESSED 9/13/93 INSPECTOR KEITH WHITE DATE 09/1319/93 DATA FROM OLD VAX INFO | |
0937065921 | 2012-11-02 | UrbanProduction Wells | No Violations | I completed an urban well production well inspection status check. My inspection found the well equipped with a plunger lift unit that was surrounded by a chain link fence and the proper identification sign. The tank battery was surrounded by a chain link fence, a dike, and contained one, 210 barrel oil/brine storage tank, a separator, and the proper identification sign. I noticed no visible spills or leaks. The lease road was in good working condition. There are no violations at this time. |
13503 | PL | No Violations | ||
1353365948 | 2013-06-05 | UrbanProduction Wells | No Violations | I performed an inspection as a request from ODNR Hydrologist Kyle Tharp in reference to complaint ID 4344. My inspection found the well in production. It was equipped with a plunger lift unit and surrounded by a locked chain link fence. An identification sign was posted on the fence. The tank battery contained one, 210 barrel production tank and a separator. There were plugs in the 4 and 2 load lines. The tank battery was surrounded by a locked chain link fence. The proper identification sign was posted. The dike was in good condition and capable of meeting containment requirements. I noticed no visible spills or leak at the tank battery, wellhead, or surrounding area. The lease road was in good condition with an open gate at the entrance. This well was placed into production prior to House Bill 278. |
1490195193 | 2017-03-22 | UrbanProduction Wells | No Violations
-up line is secure with a plug. Identification signs are posted at the tank battery and well. Chain link fences surround the tank battery and well. There is a lock on the fencing around the tank battery. The access road is in good repair with a locked gate at the entrance. The equipment on site:
| |
937065921 | 2012-11-2 0:00: | UP | No Violations | 0.50 |
For data sources see[9]