X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-22368

Well Details

Well ID: 34-155-22368
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Brookfield Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: O' BRIEN J
License Status: Producing
License Date: 1983-07-21
Spud Date: 1983-09-15
Spud Drilling Contractor: ARMSTRONG DRLG
Final Drill Date: 1983-09-20
Well Total Depth: 5170.00 ft
Configuration: Vertical
Latitude: 41.260000
Longitude: -80.520000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1983-07-21 Issued Date 7/21/83 Expired Date 1/17/84 Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05170 Proposed Drill Depth 05170
Original Spud 1983-09-16
Completed 1983-09-20
Reached Total Depth 1983-09-20
CO 1983-11-09 54 TITAN ENERGY CORP GeoDate 7/21/83
Construction Permit Expires 1984-01-17
Completion Report Received 1984-04-24
CO 1995-09-20 1639 BASS ENERGY CO INC GeoDate 7/21/83
Change of Owner 2000-10-21 Operator changed from 1639, BASS ENERGY CO INC to 1333, BARR ROBT/dba BIG SKY PET
Change of Owner 2017-04-13 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2017-04-13

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4884 5018 0
4884 5018 0
2006-09-11 4939 5018 26
4939 5018 26
4884 5018 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
ACID 0 500 Gal 0 FRAC;H2O,SAND,N2,ACID
N2 0 198 Mscf 0
H2O 0 60000 Gal 70000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 TITAN ENERGY CORP 31956.00 72.00 0
1986 TITAN ENERGY CORP 11391.00 31.00 365
1987 TITAN ENERGY CORP 7382.00 0.00 365
1988 TITAN ENERGY CORP 8075.00 0.00 365
1989 TITAN ENERGY CORP 17845.00 60.00 365
1990 TITAN ENERGY CORP 14301.00 0.00 365
1991 TITAN ENERGY CORP 3503.00 0.00 365
1992 TITAN ENERGY CORP 3583.00 0.00 365
1993 TITAN ENERGY CORP 3797.00 0.00 365
1994 TITAN ENERGY CORP 1984.00 0.00 365
1996 SABRE ENERGY CORPORATION 2946.00 0.00 365
1997 BASS ENERGY CO INC 1880.00 0.00 365
1998 BASS ENERGY CO INC 831.00 0.00 365
1999 BASS ENERGY CO INC 0.00 0.00 0
2001 BIG SKY ENERGY INC 7211.00 0.00 365
2002 BIG SKY ENERGY INC 6555.00 0.00 365
2003 BIG SKY ENERGY INC 2628.00 0.00 365
2004 BIG SKY ENERGY INC 4170.00 0.00 365
2005 BIG SKY ENERGY INC 2196.00 0.00 365
2006 BIG SKY ENERGY INC 1436.00 0.00 365
2007 BIG SKY ENERGY INC 1487.00 0.00 365
2008 BIG SKY ENERGY INC 3496.00 0.00 365
2009 BIG SKY ENERGY INC 1645.00 0.00 365
2010 BIG SKY ENERGY INC 954.00 0.00 365
2011 BIG SKY ENERGY INC 2269.00 0.00 365
2012 BIG SKY ENERGY INC 2576.00 0.00 366
2013 BIG SKY ENERGY INC 1886.00 0.00 365
2014 BIG SKY ENERGY INC 1792.00 0.00 365
2016 BIG SKY ENERGY INC 847.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 TITAN ENERGY CORP Brine 0 0
1986 TITAN ENERGY CORP Brine 0 365
1987 TITAN ENERGY CORP Brine 0 365
1988 TITAN ENERGY CORP Brine 0 365
1989 TITAN ENERGY CORP Brine 0 365
1990 TITAN ENERGY CORP Brine 0 365
1991 TITAN ENERGY CORP Brine 0 365
1992 TITAN ENERGY CORP Brine 0 365
1993 TITAN ENERGY CORP Brine 35 365
1994 TITAN ENERGY CORP Brine 0 365
1996 SABRE ENERGY CORPORATION Brine 10 365
1997 BASS ENERGY CO INC Brine 0 365
1998 BASS ENERGY CO INC Brine 0 365
1999 BASS ENERGY CO INC Brine 0 0
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2010 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 0 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-819204157 2016-6-13 0:00: UP No Violations 1.00
-908233168 2016-6-27 0:00: UP No Violations 0.70
0000PL3884 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0026834059 2016-06-08 UrbanProduction Wells No Violations

-2369. The two storage tanks and separator are surrounded by overgrown weeds. There is no identification at the well or tank battery. There are no further changes since the previous inspection on 4/28/2016. Photos were taken and are available upon request. I called and left a message on 6/7/2016 with Bob Barr for a return call concerning the complaint.

The operator needs to: Repair the defective casing and tubing at the clamp.

0100461536 2017-03-10 UrbanProduction Wells No Violations

-

Big Sky still needs to: The well needs shut in immediately per the temporary restraining order issued by the Trumbull County Court of Common Pleas, dated 4/11/2016. Cut down the overgrown weeds surrounding the production equipment. Post the proper identification at the well and tank battery. Build a dike around the tanks.

The equipment on the pad consists of the following:



0141295561 2016-04-28 UrbanProduction Wells Violations Noted I conducted an inspection of this well. The well was equipped with a plunger lift assembly. The valves at the welhead were closed. A domestic gas line came off of the 4.5 casing. The tank battery consisted of one, 100 BBL production tank, one, 50 BBL brine tank and a mechanical separator. The tank battery was shared with well 22369. The chart in the mechanical separator was dated 4/4/16. The tank battery was partially diked. The signage was not legible and needs replaced. The access was stable and driveable.
0143342148 2016-07-13 UrbanProduction Wells No Violations I was on location in reference to complaint ID 5349. At the time of my inspection, I found the gas leak at the well repaired on 7/7/2016. The 2 flow line valve coming off of the well is closed. The domestic gas supply coming off of the wellhead is disconnected.
0819204157 2016-06-13 UrbanProduction Wells No Violations
0908233168 2016-06-27 UrbanProduction Wells No Violations


Big Sky still needs to: Repair the gas leak at the well. Cut down the overgrown weeds surrounding the production equipment. Post the proper identification at the well and tank battery.

100461536 2017-3-10 0:00: UP No Violations 0.70
1043804603 2016-09-07 UrbanProduction Wells No Violations
141295561 2016-4-28 0:00: UP No Violations
143342148 2016-7-13 0:00: UP No Violations 0.50
1466615484 2016-06-20 UrbanProduction Wells No Violations


Big Sky still needs to: Repair the gas leak at the well. Cut down the overgrown weeds surrounding the production equipment. Post the proper identification at the well and tank battery.

1468004365 2016-07-08 UrbanProduction Wells No Violations

reference to compliance notice # 141295561 and complaint ID 5349. At the time of my inspection, I


Emergency repair operations were:


-2368, to the 100 bbl storage tank.



--

1468427117 2016-07-11 Production Wells No Violations


Emergency repair operations were:


-passed the well into the 100 barrel tank.




Lance Martinez Ronnie Boltz Jeff Brooks John Davis Rick Morrow

DOGRM: John Fleming Fred Romeo and Rick Anderson

2032364766 2007-07-18 Production Wells No Violations no violations .
26834059 2016-6-8 0:00:0 UP No Violations 1.00
945632598 2020-9-21 0:00: UP No Violations
PL3884 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0141295561 US-OH-112150 2016-05-26 ID (a-i)

For data sources see[9]

References