Well Details

Well ID: 34-155-22316
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Bristol Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: ST JOHN UNIT
License Status: Producing
License Date: 1983-01-06
Spud Date: 1983-02-08
Spud Drilling Contractor: MOBILE AIR DRLG
Final Drill Date: 1983-02-14
Well Total Depth: 4150.00 ft
Configuration: Vertical
Latitude: 41.410000
Longitude: -80.860000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1983-01-06 Issued Date 12/30/82 Expired Date 6/28/83 Acres 0107113 Tool Type RTA Proposed Formation CLINTON Proposed Depth 04150 Proposed Drill Depth 04150
Original Spud 1983-02-09 PERMIT EXPIRED.
Completed 1983-02-14 PERMIT EXPIRED.
Reached Total Depth 1983-02-14 PERMIT EXPIRED.
Construction Permit Expires 1983-06-28 PERMIT EXPIRED.
CO 1983-12-31 130 LESLIE OIL & GAS CO INC GeoDate 1/6/83
Completion Report Received 1984-08-17 PERMIT EXPIRED.
CO 1993-09-27 54 TITAN ENERGY CORP GeoDate 1/6/83
Change of Owner 1998-01-26 Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET
Record Last Modified 2017-02-15 PERMIT EXPIRED.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3890 3965 0
3890 3965 0
2006-09-11 3928 3962 13
3928 3962 13
3890 3965 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1544 Bbl 50000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 LESLIE OIL & GAS CO INC 2964.00 588.00 365
1986 LESLIE OIL & GAS CO INC 2417.00 485.00 365
1989 LESLIE OIL & GAS CO INC 2055.00 343.00 365
1990 LESLIE OIL & GAS CO INC 1732.00 273.00 365
1991 LESLIE OIL & GAS CO INC 712.00 188.00 365
1993 TITAN ENERGY CORP 0.00 125.00 365
1994 TITAN ENERGY CORP 92.00 163.00 365
1997 TITAN ENERGY CORP 17.00 120.00 245
2000 BIG SKY ENERGY INC 0.00 36.00 365
2001 BIG SKY ENERGY INC 118.00 0.00 365
2002 BIG SKY ENERGY INC 152.00 120.00 365
2003 BIG SKY ENERGY INC 17.00 0.00 365
2004 BIG SKY ENERGY INC 43.00 99.00 365
2005 BIG SKY ENERGY INC 58.00 52.00 365
2006 BIG SKY ENERGY INC 368.00 244.00 365
2007 BIG SKY ENERGY INC 152.00 90.00 365
2008 BIG SKY ENERGY INC 2.00 0.00 365
2009 BIG SKY ENERGY INC 445.00 107.00 365
2010 BIG SKY ENERGY INC 211.00 112.00 365
2011 BIG SKY ENERGY INC 59.00 89.00 365
2012 BIG SKY ENERGY INC 161.00 44.00 366
2013 BIG SKY ENERGY INC 190.00 135.00 250
2014 BIG SKY ENERGY INC 697.00 107.00 365
2016 BIG SKY ENERGY INC 0.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 LESLIE OIL & GAS CO INC Brine 422 365
1986 LESLIE OIL & GAS CO INC Brine 518 365
1989 LESLIE OIL & GAS CO INC Brine 0 365
1990 LESLIE OIL & GAS CO INC Brine 0 365
1991 LESLIE OIL & GAS CO INC Brine 0 365
1993 TITAN ENERGY CORP Brine 0 365
1994 TITAN ENERGY CORP Brine 43 365
1997 TITAN ENERGY CORP Brine 42 245
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2010 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 144 250
2014 BIG SKY ENERGY INC Brine 144 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1122374021 2014-2-28 0:00: PW No Violations
-1265268980 2018-3-12 0:00: PW No Violations
-1288506250 2015-5-26 0:00: PW No Violations 0.70
-36008195 2015-6-22 0:00: PW No Violations 1.00
0000PL3921 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0036008195 2015-06-22 Production Wells No Violations I was on location for a follow-up inspection in reference to compliance notice no. 1430911289. During my inspection, I found the tank battery full of water with oil hugging the entire edge of the dike wall. I took two high level Quantab readings of the water inside the dike. After 5 minutes, the results of the readings were 5.2 and 5.4 which equates to 1,304 to 1,416 ppm chlorides. I observed a production chart dated 5/15. Inside the production meter with the chart were three (3), pink, field tickets from Kleese Development Inc. (KDA). The northeast corner of the dike has not been repaired. The spare pumpjack has not been removed from the location. I called Bob Barr at 740-260-2154 and left a message with for a return call concerning the tank battery. Photos were taken and are available upon request.
0456328867 2015-07-08 Production Wells No Violations I was on location for a follow-up inspection in reference to compliance notice no. 1430911289. During my inspection, I found the tank battery full of water. I observed several absorbent pads floating in the water on the north and northeast corning of the tank battery I took two high level Quantab readings of the water inside the dike. After 5 minutes, the results of the readings were both 4.6 which equates to 1,020 ppm chlorides. I observed a production chart dated 5/15. The northeast corner of the dike has not been repaired. The spare pumpjack has not been removed from the location. I called Bob Barr at 740-260-2154 and left a message with for a return call concerning the tank battery. Photos were taken and are available upon request.
0625351048 2014-12-04 Administrative Inspection No Violations I performed an administrative inspection for Compliance Notice #1401366511, which has been closed at this time. Operator was granted a stay in reference to Chiefs Order 2014-43.
0777261121 2015-05-06 Production Wells No Violations I was on location for a follow-up inspection in reference to compliance notice no. 1430911289. During my inspection, I found the diked tank battery half full of water. I observed all of the gravel inside the dike had a rusty, orange color. I took a high level Quantab reading of the water in the dike. After 5 minutes, the result of the high level Quantab was a 9, which equates to 6,396 ppm chlorides. Upon further inspection, I found a one foot section of the north dike wall allowing water from inside the dike to leach through. The spare pumpjack has not been removed from the location. I called and spoke with Don Gooseman, field supervisor for Big Sky. Mr. Gooseman stated the tank battery is on a list to be addressed. I instructed Mr. Gooseman that the water inside the dike and the gravel inside the dike needed removed. Also, I told Mr. Gooseman to repair the north side of the dike and remove the spare pumpjack. Next, I called and left a message with Bob Barr to return my call. A follow-up inspection will be conducted by 5/17/2015. Additional photos were taken and available upon request.
1122374021 2014-02-28 Production Wells Violations Noted I checked this well to determine if the company is in compliance with chiefs order # 2014-43 . I found the tank battery is equipped with 1 100 bbl , 1 210 bbl steel tanks and 1 separator . The 210 bbl tank was 1/2 full of fluid . I could not access the 100 bbl tank to determine the amount of fluid in it due to there was no ladder to access it . The chart on the gas meter was marked with the date of 2-26 with no year indicated . The clock in the gas meter was running but there was no indication on the chart the well was producing or not . The valves from the flow line to the separator and from the separator to the sales line were open . At the well location I found the well is equipped with a pumping unit . The pumping unit was not operating at the time of my inspection . The valve from the flow line to the well was open . There was a active domestic hook-up off of the production casing . NOTE: This well shares a common tank battery with P# 2328 . I could not determine definitively if the well was or was not in production .
1265268980 2018-03-12 Production Wells No Violations I conducted a compliance notice folllow-up inspection for compliance notice 1430911289. At the time of my inspection, I found the well not in production. The motor and belt are still missing from the pumping unit. The flow line valves were open. The gravel in the diked tank battery has not been removed and replaced with cleaned out. The 100 BBL tank is corroding along the base of the tank and has rust pitting. The pumping unit with no motor or weights is still on location next to the tank battery. There is an identification sign posted at the tank battery but not at the well. The well shares the tank battery with permit 2-2328.
1288506250 2015-05-26 Production Wells No Violations I was on location for a follow-up inspection in reference to compliance notice no. 1430911289. During my inspection, I found the water inside the diked tank battery completely evaporated. All of the gravel, soil and weeds are a rusty color. The spare pumpjack has not been removed from the location. There is a rusty, brine stain on the outside of the dike in the northwest corner indicating seepage. I called and left a message with Bob Barr to return my call concerning the condition of the tank battery. Additional photos were taken and are available upon request.
1333718600 2012-04-05 Production Wells No Violations My inspection of this well site found this well was capable of production. No violations were found at this time.
1401366511 2014-05-28 Production Wells Violations Noted

-43. I noticed during my inspection the pumpjack in production and operating. The tank battery consisted of a 210 barrel production tank, a 100 barrel brine tank, and a separator. A dike surrounded the two tanks and separator. The inside of the separator was oil stained and missing a door. There was a 7 day production chart on the sales line dated 5/28/2014. The tank battery and lease road was shared with permit number 2-3328. An identification sign was posted on the production tank, but not at the pumpjack. Photos were taken of the production equipment and of the well in operation. The well was in production which was in non--43. The well needs to be shut-in immediately.

1430911289 2015-04-14 Production Wells Violations Noted I was on location for a status check. During my inspection, I found the diked tank battery full of water with a slight sheen on top. The tank battery consists of a 210 barrel production tank, a 100 barrel brine tank and a mechanical separator. An identification sign is posted. The dike surrounds the tank battery. I observed a spare pumpjack positioned next to the tank battery stripped of weights, a motor, and belts. Upon further inspection of the water in the tank battery, I placed four (4) low level Quantabs on all four sides of the dike. After several minutes, the reading on the low level Quantabs was maxed out. Next, I placed four (4) high level Quantab on all four sides of the dike. After several minutes, the reading on the high level Quantabs was a 9, which equates to 6,396 ppm chlorides. The water is contained inside the dike. I immediately called Don Gooseman, field supervisor for Big Sky Energy. I told Mr. Gooseman of my findings and instructed him that the water needed to be removed immediately along with all impacted soil, gravel and weeds. Also, I told Mr. Gooseman to inspect both tanks for a possible leak and to remove the stripped pumpjack from the location. Mr. Gooseman stated the companys water truck was not in operation. Also, Mr. Gooseman stated he would contact Bob Barr, owner of Big Sky Energy about getting a water truck. Mr. Gooseman claimed that the 100 barrel brine tank may be leaking and needs to be replaced. Next, I called and left a message with Bob Barr to return my call concerning the condition of the tank battery. I researched our RBDMS database and found Big Sky did not file annual production for 2013. A compliance notice will be issued for failure to keep dike free of water or oil. A follow-up inspection will be conducted by 4/24/2015. Photos were taken and available upon request.
1460123073 2016-04-08 Production Wells No Violations I was on location for a follow-up inspection in reference to compliance notice no. 1430911289. My inspection found the well is equipped with a pumpjack. The motor has been removed from the pump jack. The valves on the well are in the open position. There is a spare pump jack on location that needs to be removed as requested by Inspector Skidmore. The dike surrounding the tank battery is currently full of water. There are absorbent pads floating in multiple locations inside the tank battery. A quantab revealed the water contains 503 ppm chlorides. The tank battery consists of a 210 BBL production tank, a 100 BBL brine tank, and a mechanical separator. The valves on the separator are in the open position. The production chart is saturated with water and is not legible. The impacted soil and gravel inside the tank battery has not been removed as requested by Inspector Skidmore. The tank battery and lease road are being shared with permit #2-2328. Photos are avaliable upon request.
1472488049 2016-08-29 Production Wells No Violations

-2328.

Big Sky still needs to: Post the proper identification at the well. Remove all brine impacted gravel in the diked tank battery and replace with clean gravel.

1484755166 2015-05-19 Production Wells No Violations I was on location for a follow-up inspection in reference to compliance notice no. 1430911289. During my inspection, I found water in the northwest corner of the diked tank battery and a three foot by four foot pool of water in front of the separator. I observed all of the gravel inside the dike had a rusty, orange color. I took two, high level Quantab readings of the water in the dike. After 5 minutes, the results of the high level Quantabs were both a 9, which equates to 6,396 ppm chlorides. Upon further inspection, I found the one foot section in the northwest corner of the dike still not repaired. The spare pumpjack has not been removed from the location. I called and left a message with Bob Barr to return my call concerning the condition of the tank battery. Photos were taken and available upon request.
456328867 2015-7-8 0:00:0 PW No Violations 1.00
625351048 2014-12-4 0:00: AM No Violations 0.20
777261121 2015-5-6 0:00:0 PW No Violations 1.00
PL3921 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1122374021 US-OH-103094 2014-03-21 Violation of separator spacing requirements
1401366511 US-OH-111876 2015-02-06 Failure to register/obtain or maintain bond/insurance
1430911289 US-OH-112594 2015-07-31 No SPCC dike/or failure to keep dike free of water or oil

For data sources see[9]