Well Details

Well ID: 34-155-22238
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Brookfield Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: HACKETT-KETTLER UNIT
License Status: Producing
License Date: 1982-08-11
Spud Date: 1982-11-10
Spud Drilling Contractor: ARMSTRONG DRLG
Final Drill Date: 1982-11-18
Well Total Depth: 5070.00 ft
Configuration: Vertical
Latitude: 41.240000
Longitude: -80.530000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-08-11 Issued Date 8/11/82 Expired Date 2/1/83 Acres 0053650 Tool Type RTA Proposed Formation CLINTON Proposed Depth 05070 Proposed Drill Depth 05070
Original Spud 1982-11-11
Completed 1982-11-18
Reached Total Depth 1982-11-18
CO 1983-01-15 54 TITAN ENERGY CORP GeoDate 8/11/82
Construction Permit Expires 1983-02-01
Completion Report Received 1983-03-11
Change of Owner 1998-01-26 Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET
Change of Owner 2017-04-13 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2017-04-13

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 4843 4929 0
4843 4929 0
2006-09-11 4853 4910 23
4853 4910 23
4843 4929 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 65000 Gal 70000 FRAC;65MG H2O,70M# SAND,250MCF N2,ACID
N2 0 250 Mscf 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 TITAN ENERGY CORP 9272.00 278.00 0
1985 TITAN ENERGY CORP 2967.00 278.00 365
1986 TITAN ENERGY CORP 4669.00 79.00 365
1987 TITAN ENERGY CORP 3561.00 84.00 365
1988 TITAN ENERGY CORP 4723.00 159.00 365
1989 TITAN ENERGY CORP 3809.00 73.00 365
1990 TITAN ENERGY CORP 3366.00 78.00 365
1991 TITAN ENERGY CORP 1546.00 0.00 365
1992 TITAN ENERGY CORP 1540.00 76.00 365
1993 TITAN ENERGY CORP 1755.00 72.00 365
1994 TITAN ENERGY CORP 762.00 0.00 365
1997 TITAN ENERGY CORP 2610.00 139.00 245
2000 BIG SKY ENERGY INC 2594.00 0.00 365
2001 BIG SKY ENERGY INC 2610.00 95.00 365
2002 BIG SKY ENERGY INC 2007.00 44.00 365
2003 BIG SKY ENERGY INC 2200.00 0.00 365
2004 BIG SKY ENERGY INC 2364.00 0.00 365
2005 BIG SKY ENERGY INC 1618.00 35.00 365
2006 BIG SKY ENERGY INC 2255.00 0.00 365
2007 BIG SKY ENERGY INC 1553.00 0.00 365
2008 BIG SKY ENERGY INC 2653.00 40.00 365
2009 BIG SKY ENERGY INC 1867.00 0.00 365
2010 BIG SKY ENERGY INC 2274.00 42.00 365
2011 BIG SKY ENERGY INC 2380.00 0.00 365
2012 BIG SKY ENERGY INC 968.00 0.00 366
2013 BIG SKY ENERGY INC 898.00 0.00 365
2014 BIG SKY ENERGY INC 643.00 0.00 365
2016 BIG SKY ENERGY INC 207.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 TITAN ENERGY CORP Brine 0 0
1985 TITAN ENERGY CORP Brine 0 365
1986 TITAN ENERGY CORP Brine 0 365
1987 TITAN ENERGY CORP Brine 0 365
1988 TITAN ENERGY CORP Brine 0 365
1989 TITAN ENERGY CORP Brine 0 365
1990 TITAN ENERGY CORP Brine 0 365
1991 TITAN ENERGY CORP Brine 0 365
1992 TITAN ENERGY CORP Brine 0 365
1993 TITAN ENERGY CORP Brine 0 365
1994 TITAN ENERGY CORP Brine 0 365
1997 TITAN ENERGY CORP Brine 245
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2010 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 0 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1086033462 2020-3-18 0:00: UP No Violations
-1144011082 2014-3-4 0:00:0 UP No Violations 1.00
-1537402212 2016-9-13 0:00: UP No Violations 0.50
-343996696 2016-4-7 0:00:0 UP No Violations 0.70
-71307476 2016-4-6 0:00:0 UP No Violations 1.00
0000PL3975 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0071307476 2016-04-06 UrbanProduction Wells No Violations I was on location in reference to compliance to Chiefs Order 2016--4-16. Photos have been taken and available upon request.
0343996696 2016-04-07 UrbanProduction Wells No Violations I was on location in reference to compliance to Chiefs Order 2016-105. At the time of my inspection, I found the 2 flow line valve at the wellhead in the open position. The 2 sales line valve coming off of the separator is in the open position. There is a production meter and 31 day chart in the separator dated 4 April 2016. Photos were taken and available upon request.
1111665897 2014-12-04 Administrative Inspection No Violations I performed an administrative inspection for Compliance Notice #-1144011082, which has been closed at this time. Operator was granted a stay in reference to Chiefs Order 2014-43.
1144011082 2014-03-04 UrbanProduction Wells Violations Noted I was on location to check compliance to Chiefs Order 2014-43. My inspection found the well was equipped with a plunger lift unit. The valve leading to the flow line from the well was open. There was a domestic flow line coming off the 4.5 casing. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank, and a heat, treated separator. The dike was slightly weathered; however, it meets containment requirements. The heat, treated separator has the proper spacing. The flow line valves leading to and exiting the separator were open. The lease road was in stable condition. Photos were taken of all the production equipment. The well was in production which was in non-compliance of Chiefs order #2014-43. The well needs to be shut-in immediately.
1459952055 2016-03-21 UrbanProduction Wells No Violations


The equipment on the site consists of the following:


1 Mechanical separator 1 Production well

1461755820 2016-04-25 UrbanProduction Wells No Violations I was on location in reference to compliance to Chiefs Order 2016-105. At the time of my inspection, I found the 2 flow line valve at the wellhead in the open position. The 2 sales line valve coming off of the separator is in the open position. There is a production meter and 31 day chart in the separator dated 4 April 2016. Photos were taken and available upon request.
1537402212 2016-09-13 UrbanProduction Wells No Violations
PL3975 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1144011082 US-OH-103673 2015-02-06 Non registered operator/ Bond/ Insurance

For data sources see[9]