X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-22060

Well Details

Well ID: 34-155-22060
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Bristol Township
Operator Name: BIG SKY ENERGY INC
Well Pad ID:
Farm/Lease Name: MACDONALD
License Status: Producing
License Date: 1982-09-02
Spud Date: 1982-09-30
Spud Drilling Contractor: PERKINS DRLG
Final Drill Date: 1982-10-04
Well Total Depth: 4140.00 ft
Configuration: Vertical
Latitude: 41.410000
Longitude: -80.890000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1982-09-02 Issued Date 9/2/82 Expired Date 3/1/83 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04140 Proposed Drill Depth 04140
Original Spud 1982-09-30 PERMIT EXPIRED.
Completed 1982-10-04 PERMIT EXPIRED.
Reached Total Depth 1982-10-04 PERMIT EXPIRED.
Construction Permit Expires 1983-03-01 PERMIT EXPIRED.
CO 1983-12-31 130 LESLIE OIL & GAS CO INC GeoDate 9/2/82
Completion Report Received 1984-08-17 PERMIT EXPIRED.
CO 1993-09-27 54 TITAN ENERGY CORP GeoDate 9/2/82
Change of Owner 1998-01-26 Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET
Record Last Modified 2017-02-15 PERMIT EXPIRED.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3844 3978 0
3844 3978 0
2006-09-11 3865 3947 16
3865 3947 16
3844 3978 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 66000 Gal 49000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1985 LESLIE OIL & GAS CO INC 2656.00 1145.00 365
1986 LESLIE OIL & GAS CO INC 2817.00 631.00 365
1989 LESLIE OIL & GAS CO INC 1739.00 1467.00 365
1990 LESLIE OIL & GAS CO INC 2362.00 1088.00 365
1991 LESLIE OIL & GAS CO INC 1824.00 692.00 365
1992 TITAN ENERGY CORP 1276.00 656.00 365
1993 TITAN ENERGY CORP 1593.00 708.00 365
1994 TITAN ENERGY CORP 1154.00 603.00 365
1997 TITAN ENERGY CORP 780.00 423.00 245
2000 BIG SKY ENERGY INC 63.00 121.00 365
2001 BIG SKY ENERGY INC 380.00 180.00 365
2002 BIG SKY ENERGY INC 797.00 330.00 365
2003 BIG SKY ENERGY INC 341.00 183.00 365
2004 BIG SKY ENERGY INC 1247.00 240.00 365
2005 BIG SKY ENERGY INC 1177.00 375.00 365
2006 BIG SKY ENERGY INC 1800.00 281.00 365
2007 BIG SKY ENERGY INC 1333.00 338.00 365
2008 BIG SKY ENERGY INC 433.00 83.00 365
2009 BIG SKY ENERGY INC 2112.00 271.00 365
2010 BIG SKY ENERGY INC 2800.00 337.00 365
2011 BIG SKY ENERGY INC 778.00 120.00 365
2012 BIG SKY ENERGY INC 965.00 28.00 366
2013 BIG SKY ENERGY INC 303.00 176.00 250
2014 BIG SKY ENERGY INC 522.00 118.00 365
2016 BIG SKY ENERGY INC 118.00 68.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1985 LESLIE OIL & GAS CO INC Brine 100 365
1986 LESLIE OIL & GAS CO INC Brine 0 365
1989 LESLIE OIL & GAS CO INC Brine 0 365
1990 LESLIE OIL & GAS CO INC Brine 0 365
1991 LESLIE OIL & GAS CO INC Brine 0 365
1992 TITAN ENERGY CORP Brine 0 365
1993 TITAN ENERGY CORP Brine 124 365
1994 TITAN ENERGY CORP Brine 262 365
1997 TITAN ENERGY CORP Brine 245
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2010 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 131 250
2014 BIG SKY ENERGY INC Brine 112 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1022140214 2013-11-6 0:00: PW No Violations 1.50
-1585089435 2012-10-23 0:00 PW No Violations 0.50
-779094285 2012-9-20 0:00: PW No Violations 0.50
-868096804 2019-3-13 0:00: PW No Violations
0000PL4055 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0098792919 2016-04-08 Production Wells No Violations I was on location in reference to compliance notice 1440176584. My inspection found the dike surrounding the tank battery to have 2 BBLs of oil contained inside of it. The production tank appears to have been over flowed and there is a line repair clamp on the 2 dump line leading from the separator to the production tank. After reviewing previous inspection reports, the 100 BBL brine tank was to be removed from the tank battery. The tank battery consists of a 100 BBL production tank, a 100 BBL brine tank, a mechanical separator, and a compressor. The oil saturated stone and soil needs to be removed from inside the tank battery. There is currently soil sitting on plastic liner outside the tank battery on the lease road from a previous spill. I contacted Mr. Barr and left a message to notify him of the issues on the location. Fred Romeo from Emergency Response was on location and attempted to contact Mr. Barr as well. He texted Fred to let him know he would start clean up at the location on 4/13/16.
0339614025 2017-06-20 Production Wells No Violations I was on location to assess compliance notice # 1440176584. I found the oil impacted gravel and soil at the tank battery and pumping unit have not been removed and replaced as requested. The production equipment and wellhead is stained from oil, paraffin and brine. The saturated absorbent pads and booms are still lying in the tank battery.

The operator still needs to: Remove the leaking production tank. Remove all impacted gravel and soil from the tank battery and replace with clean gravel. Remove all of the impacted soil at the wellhead. Make repairs at the well to prevent further leaks.

0779094285 2012-09-20 Production Wells No Violations I conducted a production well inspection status check. My inspection found the well equipped with a pumping unit that was in good condition. The tank battery contained two, 100 barrel oil/brine storage tanks, a separator, and the proper identification. I noticed the motor running at the pumping unit with a broken belt and oil stained gravel at the tank battery. I called Jaime Campbell at 440-858-7252 to tell him the belt needed repaired and the oil stained gravel needed removed. I will conduct a follow-up inspection by 10/01/2012.
0821264087 2016-11-17 Production Wells No Violations I was on location to assess compliance notice # 1440176584. At the time of my inspection, I found the status of the well and tank battery has not changed. Oil impacted gravel and soil has not been cleaned up in the tank battery or at the well. The production equipment and wellhead is stained from oil, paraffin and brine. There are several saturated absorbent pads and booms lying in the tank battery. Photos have been taken and are available upon request.

The operator still needs to: Remove the leaking production tank. Remove all impacted gravel and soil from the tank battery and replace with clean gravel. Remove all of the impacted soil at the wellhead. Make repairs at the well to prevent further leaks.

0868096804 2019-03-13 Production Wells No Violations I conducted a compliance notice follow-up for compliance notice 1440176584, regarding the cleanup of impacted soil at the well and tank battery locations. The oil impacted gravel and soil at the tank battery and pumping unit showed no cleanup of impacted site was conducted, at the time of this inspection. The area inside the diked tank battery had very dark, stained soil and stone from the previous release but no active leak was observed, during this inspection. The stenciled identification sign was posted on a 100 BBL tank but missing well information. The well was not in production and the wellhead is stained from old oil which still needs cleaned up. The diked tank battery still needs cleaned up and the impacted material needs to be disposed of at a proper facility. Update identification with the well information.
1022140214 2013-11-06 Production Wells Violations Noted My inspection found the well in production. I noticed oil and brine stained gravel throughout the tank battery. Also, there was oil and brine stained grass in a wet area on the outside of the tank battery on the north side; the impacted area was approximately 10 by 20. Peat moss was spread through the tank battery and the wet grassy area. Two 2 load lines next to the production tanks were missing plugs and the separator was completely oil stained. I dug a 6 sump inside the tank battery and performed a chloride test using a high level Quantab. Then, I performed 3 chloride tests outside the tank battery in the impacted grassy area using high level Quantabs. The Quantab test result from inside the tank battery was approximately 3,800 part per million. The three Quantab test results from the wet grassy area was approximately 400 parts per million each. I performed two pH tests in the wet grassy area and the results came to 7. Photos of the entire area were taken. During my inspection, Bobby Barr Jr. arrived on location. Bobby stated he knew about the oil and brine stained gravel and grass. Bobby claimed a backhoe and other equipment was in route to the tank battery to begin clean-up operations. I instructed Bobby to remove all of the impacted gravel and grass and replace with clean gravel. I told Bobby to reseed the area impacted on the north side of tank battery. Also, I told Bobby to install two, 2 plugs on the load lines and to clean up the oil stained separator.
1146073290 2016-06-03 Production Wells No Violations I was on location to assess compliance notice #1440176584. At the time of my inspection, I found the well not in production. There are no belts on the motor for the pumping unit. The approximately 2-3 bbls of oil in the tank battery and the oil impacted soil at the well still has not been cleaned up. There is a stenciled identification sign on a 100 bbl production tank. There are no changes from previous inspections. Photos have been taken and are available upon request.
1269473640 2013-11-20 Production Wells No Violations My inspection found Big Sky still cleaning up the oil and brine stained gravel inside the tank battery. The two, 2 load line plugs were still missing. I called Bobby Barr, Jr. concerning the clean-up operations. Bobby stated Big Sky was working on removing more of the impacted material and that the plugs would be installed today. I will continue to monitor the operations.
1370007348 2018-03-06 Production Wells No Violations DOGRM Steve Ochs and my self performed a follow-up inspection (Chiefs Order 2016-105 ) on the above location the tank battery is equipped with 2-100 barrel tanks and 1-horzional separator. The dike is full of water. All values are shut at the well head no gas sales recorded on the chart. There is a small compressor also on location. No ID signs posted. Well not in production
1384264387 2013-11-12 Production Wells No Violations My inspection found Big Sky still cleaning up the oil stained gravel in the tank battery.
1440176584 2015-08-21 Production Wells Violations Noted



Big Sky has until 8/31/2015 to correct all of the issues with the tank battery and well. Follow inspections will continue. Photos were taken and available upon

1464782028 2016-05-27 Production Wells No Violations I was on location to assess compliance notice #1440176584 with Fred Romeo from ODNR Emergency Response. At the time of my inspection, I found approximately 2-3 bbls of oil in the tank battery, saturated absorbent pads, oil/brine stained gravel and soil, and debris. There are no changes from previous inspections. Photos have been taken and are available upon request.
1467134741 2016-06-27 Production Wells No Violations I was on location to assess compliance notice # 1440176584. At the time of my inspection, I found the well not in production. The approximately 2-3 bbls of oil in the tank battery and the oil impacted soil at the well still has not been cleaned up. Several saturated absorbent pads are lying in the tank battery. Photos have been taken and are available upon request.

The operator still needs to: Remove the leaking production tank. Remove all impacted gravel and soil from the tank battery and replace with clean gravel. Remove all of the impacted soil at the wellhead. Make repairs at the well to prevent further leaks.

1467897090 2016-07-07 Production Wells No Violations I was on location to assess compliance notice # 1440176584. At the time of my inspection, I found the well not in production. The approximately 2-

The operator still needs to: Remove the leaking production tank. Remove all impacted gravel and soil from the tank battery and replace with clean gravel. Remove all of the impacted soil at the wellhead. Make repairs at the well to prevent further leaks.

1469452395 2016-07-25 Production Wells No Violations I was on location to assess compliance notice # 1440176584. At the time of my inspection, I found the well not in production. There are approximately 3-

The operator still needs to: Remove the leaking production tank. Remove all impacted gravel and soil from the tank battery and replace with clean gravel. Remove all of the impacted soil at the wellhead. Make repairs at the well to prevent further leaks.

1471613472 2016-08-19 Production Wells No Violations


The operator still needs to: Remove the leaking production tank. Remove all impacted gravel and soil from the tank battery and replace with clean gravel. Remove all of the impacted soil at the wellhead. Make repairs at the well to prevent further leaks.

1512656215 2017-12-07 Production Wells No Violations I was on location to assess compliance notice # 1440176584. I found no evidence that Big Sky Energy has started remediation of the oil impacted gravel and soil at the tank battery and pumping unit on the day of my inspection. The saturated booms and absorbent pads are still lying in the diked tank battery. There is oil saturated rags and debris still inside of the separator. The stenciled identification sign is posted on a storage tank. The wellhead is stained from oil, paraffin and brine. The belts for the motor at the pumping unit are lying on the ground. Photos have been taken and are available upon request.

The operator still needs to: Remove the leaking production tank. Remove all impacted gravel and soil from the tank battery and replace with clean gravel. Remove all of the impacted soil at the wellhead. Make repairs at the well to prevent further leaks.

1520044915 2016-06-14 Production Wells No Violations I was on location to assess compliance notice # 1440176584. At the time of my inspection, I found the well not in production. The approximately 2-3 bbls of oil in the tank battery and the oil impacted soil at the well still has not been cleaned up. Photos have been taken and are available upon request.

The operator still needs to: Remove the leaking production tank. Remove all impacted gravel and soil from the tank battery and replace with clean gravel. Remove all of the impacted soil at the wellhead. Make repairs at the well to prevent further leaks.

1585089435 2012-10-23 Production Wells No Violations I conducted a follow-up inspection. My inspection found the belt on the motor for the pumping unit fixed. I noticed rods and tubing covered by grass that needed removed. The proper identification was posted at the tank battery. I sent Jamie Campbell of Big Sky an email asking for the rods and tubing to be cleaned up. I will perform a follow-up inspection by 11/09/2012.
1943895939 2013-11-06 Production Wells No Violations I performed a compliance follow-up inspection on the clean-up operation. My inspection found the backhoe and a crew on location. Bobby stated a dump truck was in route to remove the impacted gravel and grass.
339614025 2017-6-20 0:00: PW No Violations 0.70
821264087 2016-11-17 0:00 PW No Violations 1.00
98792919 2016-4-8 0:00:0 PW No Violations
PL4055 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1022140214 US-OH-100552 2013-11-15 Failure to keep dike or pit free of brine or other wastes
1440176584 US-OH-112810 2015-09-08 Well operation causing pollution and contamination
1440176584 US-OH-112811 2015-09-08 Failure to keep dike or pit free of brine or other wastes

For data sources see[9]

References