X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-155-21676

Well Details

Well ID: 34-155-21676
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Brookfield Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: BROOKFIELD TRI-CO CONS CLUB
License Status: Producing
License Date: 1980-12-18
Spud Date: 1981-07-17
Spud Drilling Contractor:
Final Drill Date: 1981-07-24
Well Total Depth: 5169.00 ft
Configuration: Vertical
Latitude: 41.260000
Longitude: -80.540000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-12-18 54 TITAN ENERGY CORP GeoDate 12/18/80
Oil and Gas 1980-12-18 Issued Date 12/18/80 Expired Date Acres 0040000 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Original Spud 1981-07-17
Completed 1981-07-24
Reached Total Depth 1981-07-24
Completion Report Received 1981-10-28
Change of Owner 1998-01-26 Operator changed from 54, TITAN ENERGY CORP to 1333, BARR ROBT/dba BIG SKY PET
Change of Owner 2017-04-13 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2017-04-13

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4968 5044 21
4968 5044 21
4968 5044 21

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 206585 0 SCF N2
H2O 0 59000 Gal 70000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 TITAN ENERGY CORP 8215.00 146.00 0
1985 TITAN ENERGY CORP 5637.00 128.00 365
1986 TITAN ENERGY CORP 4814.00 0.00 365
1987 TITAN ENERGY CORP 4577.00 0.00 365
1988 TITAN ENERGY CORP 3963.00 0.00 365
1989 TITAN ENERGY CORP 3466.00 66.00 365
1990 TITAN ENERGY CORP 3137.00 0.00 365
1991 TITAN ENERGY CORP 1600.00 0.00 365
1992 TITAN ENERGY CORP 3807.00 0.00 365
1993 TITAN ENERGY CORP 2559.00 0.00 365
1994 TITAN ENERGY CORP 1389.00 73.00 365
1997 TITAN ENERGY CORP 2300.00 40.00 245
2000 BIG SKY ENERGY INC 2458.00 0.00 365
2001 BIG SKY ENERGY INC 2812.00 189.00 365
2002 BIG SKY ENERGY INC 3433.00 0.00 365
2003 BIG SKY ENERGY INC 2702.00 0.00 365
2004 BIG SKY ENERGY INC 2040.00 65.00 365
2005 BIG SKY ENERGY INC 2440.00 32.00 365
2006 BIG SKY ENERGY INC 2593.00 0.00 365
2007 BIG SKY ENERGY INC 2638.00 0.00 365
2011 BIG SKY ENERGY INC 2020.00 22.00 365
2012 BIG SKY ENERGY INC 1293.00 0.00 365
2013 BIG SKY ENERGY INC 604.00 0.00 365
2014 BIG SKY ENERGY INC 631.00 0.00 365
2016 BIG SKY ENERGY INC 1130.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 TITAN ENERGY CORP Brine 0 0
1985 TITAN ENERGY CORP Brine 0 365
1986 TITAN ENERGY CORP Brine 0 365
1987 TITAN ENERGY CORP Brine 0 365
1988 TITAN ENERGY CORP Brine 0 365
1989 TITAN ENERGY CORP Brine 0 365
1990 TITAN ENERGY CORP Brine 0 365
1991 TITAN ENERGY CORP Brine 0 365
1992 TITAN ENERGY CORP Brine 0 365
1993 TITAN ENERGY CORP Brine 0 365
1994 TITAN ENERGY CORP Brine 0 365
1997 TITAN ENERGY CORP Brine 245
2000 BIG SKY ENERGY INC Brine 0 365
2001 BIG SKY ENERGY INC Brine 0 365
2002 BIG SKY ENERGY INC Brine 0 365
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2007 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 365
2013 BIG SKY ENERGY INC Brine 0 365
2014 BIG SKY ENERGY INC Brine 0 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1302389020 2016-8-30 0:00: UP No Violations 0.50
-677545668 2020-3-18 0:00: UP No Violations
0000PL4088 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0079960551 2014-12-16 UrbanProduction Wells Violations Noted I was on location for a status check. During my inspection, I found the well in production. The well was equipped with a plunger lift assembly. The flow line ball valve at the well was in the open position. A domestic gas line came off of the 4.5 casing with an open flow line valve. The tank battery consisted of a 100 barrel production tank, a 50 barrel brine tank and a separator. Upon further inspection, I found the dike around the production and brine tanks that was completely weathered on the north side An identification sign was posted on the production tank. Bull plugs were installed on the production and brine tanks. There was a seven (7) day production chart inside the separator dated 12/15. The lease road was in stable condition. The well was placed into production prior to House Bill 278. According to our RBDMS database, Big Sky has failed to file annual production statements since 2007. I called and left a message with Mr. Barr for a return call concerning the condition of the tank battery and well. Big Sky is required to:


Photos were taken and available upon request.

1302389020 2016-08-30 UrbanProduction Wells No Violations
1764937310 2016-04-28 Production Wells Violations Noted My inspection found the well to be equipped with a plunger lift unit. The valves on the wellhead leading into the flow line are open. There is a domestic supply plumbed into the 4.5 casing. The tank battery consists of a 100 BBL production tank and a 50 BBL brine tank. There is 6 ft by 2 ft area of dead vegetation leading from the transfer line between the two tanks. The heated separator is outside of the tank battery with the proper spacing. The production chart was last changed on 2/29/16. The well was not in production at the time of the inspection. The identification sign is ilegible and needs replaced. The dike around the tank battery needs rebuilt. The lease road is in stable condition.
79960551 2014-12-16 0:00 UP No Violations 0.50
PL4088 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0079960551 US-OH-129090 2016-07-26 9-9-05(A)9 No SPCC dike/or failure to keep dike free of water or oil
0079960551 US-OH-129091 2016-07-26 NONEC Statement of annual production not filed
1764937310 US-OH-117548 2016-06-14 Failure to legibly identify well

For data sources see[9]

References