34-155-20716

Well Details

Well ID: 34-155-20716
Loading map...
Country: United States
State: Ohio
County: Trumbull
Municipality: Southington Township
Operator Name: VORTEX ENERGY LLC
Well Pad ID:
Farm/Lease Name: BAUGHER ROBERT & JUDITH
License Status: Producing
License Date: 1981-06-30
Spud Date: 1977-11-10
Spud Drilling Contractor:
Final Drill Date: 1977-11-16
Well Total Depth: 4240.00 ft
Configuration: Vertical
Latitude: 41.330000
Longitude: -80.920000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1977-11-10
Completed 1977-11-16
Reached Total Depth 1977-11-16
CO 1981-06-30 271 TGX CORP GeoDate 6/30/81
CO 1994-03-29 182 BELDEN & BLAKE CO GeoDate 6/30/81
Change of Owner 2002-08-09 Operator changed from 182, BELDEN & BLAKE CORPORATION to 1966, PETROX INC
Change of Owner 2004-08-31 Operator changed from 1966, PETROX, INC to 1333, BIG SKY ENERGY INC
Change of Owner 2017-11-08 Operator changed from 1333, BIG SKY ENERGY INC to 9841, VORTEX ENERGY LLC
Record Last Modified 2017-11-08

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4095 4145 12
4095 4145 12
4095 4145 12

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1464 Bbl 32240 1380# CASING PRESSURE

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 TGX CORP 6297.00 64.00 0
1985 TGX CORP 4466.00 113.00 365
1986 TGX CORP 3118.00 37.00 365
1987 TGX CORP 4327.00 73.00 365
1988 TGX CORP 5229.00 61.00 365
1989 TGX CORP 4487.00 76.00 365
1990 TGX CORP 4303.00 45.00 365
1991 TGX CORP 3452.00 58.00 365
1992 TGX CORP 3694.00 0.00 365
1993 TGX CORP 3889.00 115.00 365
1994 BELDEN & BLAKE CORPORATION 2987.00 58.00 290
1995 BELDEN & BLAKE CORPORATION 2051.00 0.00 242
1996 BELDEN & BLAKE CORPORATION 3266.00 68.00 194
1997 BELDEN & BLAKE CORPORATION 3540.00 63.00 365
1998 BELDEN & BLAKE CORPORATION 2456.00 55.00 330
1999 BELDEN & BLAKE CORPORATION 2150.00 41.00 281
2000 BELDEN & BLAKE CORPORATION 1357.00 0.00 315
2001 BELDEN & BLAKE CORPORATION 850.00 168.00 292
2002 BELDEN & BLAKE CORPORATION 872.00 36.00 198
2003 BIG SKY ENERGY INC 1041.00 31.00 365
2004 BIG SKY ENERGY INC 1981.00 0.00 365
2005 BIG SKY ENERGY INC 2524.00 0.00 365
2006 BIG SKY ENERGY INC 2872.00 103.00 365
2008 BIG SKY ENERGY INC 1586.00 81.00 365
2009 BIG SKY ENERGY INC 3346.00 0.00 365
2011 BIG SKY ENERGY INC 38.00 0.00 365
2012 BIG SKY ENERGY INC 1148.00 0.00 366
2013 BIG SKY ENERGY INC 2189.00 0.00 365
2014 BIG SKY ENERGY INC 827.00 6.00 365
2016 BIG SKY ENERGY INC 1059.00 0.00 98
2017 BIG SKY ENERGY INC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 TGX CORP Brine 160 0
1985 TGX CORP Brine 38 365
1986 TGX CORP Brine 0 365
1987 TGX CORP Brine 105 365
1988 TGX CORP Brine 0 365
1989 TGX CORP Brine 70 365
1990 TGX CORP Brine 70 365
1991 TGX CORP Brine 105 365
1992 TGX CORP Brine 5 365
1993 TGX CORP Brine 96 365
1994 BELDEN & BLAKE CORPORATION Brine 112 290
1995 BELDEN & BLAKE CORPORATION Brine 58 242
1996 BELDEN & BLAKE CORPORATION Brine 68 194
1997 BELDEN & BLAKE CORPORATION Brine 64 365
1998 BELDEN & BLAKE CORPORATION Brine 46 330
1999 BELDEN & BLAKE CORPORATION Brine 38 281
2000 BELDEN & BLAKE CORPORATION Brine 68 315
2001 BELDEN & BLAKE CORPORATION Brine 50 292
2002 BELDEN & BLAKE CORPORATION Brine 10 198
2003 BIG SKY ENERGY INC Brine 0 365
2004 BIG SKY ENERGY INC Brine 0 365
2005 BIG SKY ENERGY INC Brine 0 365
2006 BIG SKY ENERGY INC Brine 0 365
2008 BIG SKY ENERGY INC Brine 0 365
2009 BIG SKY ENERGY INC Brine 0 365
2011 BIG SKY ENERGY INC Brine 0 365
2012 BIG SKY ENERGY INC Brine 0 366
2013 BIG SKY ENERGY INC Brine 11 365
2014 BIG SKY ENERGY INC Brine 60 365
2016 BIG SKY ENERGY INC Brine 0 98
2017 BIG SKY ENERGY INC Brine 0 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1136935408 2006-12-26 0:00 PW No Violations
-1645359797 2014-10-8 0:00: AM No Violations
-16934276 2016-6-2 0:00:0 PW No Violations 0.50
-628708897 2014-3-10 0:00: PW No Violations 0.70
-773619980 2017-9-1 0:00:0 PW No Violations 1.00
0016934276 2016-06-02 Production Wells No Violations Follow-up to Compliance Notice #1285508938 issued on 5/3/2016 due to pollution and contamination issues found at this tank battery and requiring Big Sky Energy Incorporated to post the required ID at this location. My inspection found the flow line from the wellhead to the separator closed and the domestic tap at the wellhead open. The production chart indicated pressure at the separator and the production chart has been changed since the last inspection and has overprinted 3-4 weeks of production. Although the flow line valve between the wellhead and separator indicated a closed position, I could clearly hear gas moving through the separator. The valves on the separator were open at this time. An inspection of the tank battery found that none of the remedial activities required by the prior Compliance Notice have been undertaken to address the pollution and contamination at the tank battery and the proper ID signage has not been posted. Big Sky Energy Incorporated continues to be in violation of Chapter 1501.9-1-07 and 1501.9-9-05(A)10 of the Ohio Administrative Code and Chapter 1509.22(A) of the Ohio Revised Code.
0214855861 2014-01-14 Production Wells No Violations My inspection found the proper identification sign posted with the correct information per my request.
0577303717 2016-06-21 Production Wells No Violations


Big Sky still needs to: The tanks need to be steam cleaned and pulled from the tank battery. The impacted stone and soil needs to be excavated down to clean soil or clay. The contaminated soil needs to be disposed of at an approved landfill. Clean soil and stone needs to be replaced prior to rebuilding the tank battery.

0628708897 2014-03-10 Production Wells No Violations I was on location to perform a follow-up inspection to compliance notice #1393509014, which was issued in reference to Chiefs Order 2014-43. My inspection found a production chart inside the separator with no date. The flow line valves leading to and exiting the separator were open. A valve on the flow line at the well was open. The digital meter on the dump valve at the well was showing a digital number. The well was in production which was in non-compliance of Chiefs Order 2014-43. The well needs to be shut-in immediately.
0773619980 2017-09-01 Production Wells No Violations I inspected this well location as an evaluation of current conditions and follow-up to previous Compliance Notice issued for missing well identification and release of oil at the battery. At the time of this inspection, I observed the following: a wellhead with plunger-lift system and associated tank battery located on a larger, farm property. The battery was comprised of one 100-barrel, steel production tank, one 50-barrel, steel brine tank, and horizontal mechanical separator. There was a large area of oil staining at the base of the production tank, indicating a prior releases of oil to the ground surface that remained unremediated. There were no apparent active leaks, and the valve-connections at the wellhead were closed. The various elements of the production systems were in disrepair, with inactive chart recorder, and broken doors on the separator unit. Access to the well and battery were afforded by a shared-use, gravel-paved access road that was in good condition. There was no ID signage.
1115203247 2016-08-26 Production Wells No Violations


Big Sky needs to:



1136935408 2006-12-26 Production Wells No Violations no violations .
1234691965 2012-07-10 Production Wells Violations Noted On 7/10/2012, I conducted a production well inspection status check. My inspection found the well was a plunger lift unit (rabbit) that was in good condition. The tank battery contained one 100 barrel oil storage tank, with no well information on the identification sign, one 50 barrel brine storage tank and a separator. I noticed no visible spills or leaks. The lease road was in good condition, inspection not passed.
1285508938 2016-04-28 Production Wells Violations Noted I conducted this inspection to follow---105 requiring Big Sky Energy Incorporated to suspend all oil and gas operations in the State of Ohio. My inspection found the wellhead equipped with a 1.5 plunger lift system. The tubing ball valve and flow line valve at the wellhead are open and the domestic tap is open. The electronic controls at the wellhead are set to cycle in six (6) hours. Oil has leaked from the hammer union connection below the lubricator and below the tubing ball valve. No oil is on the ground but these leaks indicate a possible safety or environmental hazard if the connection(s) fail. The well produces to a horizontal separator and one of the doors is lying on the ground in front of the unit. The flow line valve and sales line valve are open at the separator. The 7 day production chart at the separator was changed on 4-21-2016 and is recording production at this time. The tank battery is diked and contains one (1) 100 barrel tank and one (1) 50 barrel brine tank. There is no ID posted at the tank battery or wellhead as required. An inspection of the tank battery revealed the presence of an oil spill that the operator was attempting to remediate. A sump has been dug in the center of the tank battery in an attempt to flush a prior spill into the hole where it could be collected. Stone and soil around the tanks are visibly impacted and the sides of the sump show affected material to a depth of 4-5. Big Sky Energy will be given one (1) week from the issuance date of this notice to perform the following remedial activities: 1) the tanks will need to be steam cleaned and pulled from the battery, 2) impacted stone and soil will be excavated down to clean soil or clay, 3) the contaminated soil will be disposed of at an approved landfill, and, 4) clean soil and stone will be replaced prior to rebuilding the t
1393509014 2014-02-26 Production Wells Violations Noted I was on location today to check compliance of Chiefs Order # 2014-43. My inspection found the well to be equipped with a plunger lift unit. The demco valve and the valve leading to the flow line on the wellhead are open. There is a domestic line producing off of the 4.5 casing. The tank battery consists of a 100 BBL production tank and a 50 BBL brine tank that is surrounded by a proper dike. The heat treated separator has the proper spacing. The flow line valve leading into the separator is currently open. The sales line valve leading out of the separator is currently open. The production chart in the separator shows the well has been produced since the last chart change on 2-19-2014. The lease road is in stable condition. The well is in production which is in non-compliance of Chiefs Order 2014-43. The well needs shut-in immediately.
1645359797 2014-10-08 Administrative Inspection No Violations The company has received a stay from the chiefs order and is allowed to operate their wells. The compliance notice on the well can be removed.
1767527633 2019-6-27 0:00: PW No Violations
1937176973 2014-02-28 Production Wells No Violations My inspection today is a follow-up inspection to Compliance Notice # 1393509014, which was issued for non-compliance of Chiefs Order # 2014-43. My inspection found the well to be equipped with a plunger lift unit. The demco valve and the valve leading to the flow line on the wellhead are open. There is a domestic line producing off of the 4.5 casing. The tank battery consists of a 100 BBL production tank and a 50 BBL brine tank that is surrounded by a proper dike. The heat treated separator has the proper spacing. The flow line valve leading into the separator is currently open. The sales line valve leading out of the separator is currently open. The production chart in the separator has been changed since my last inspection. The chart was replaced on 2-26-2014 and the new chart has shown production since it was put on. The lease road is in stable condition. The well is in production which is in non-compliance of Chiefs Order 2014-43. The well needs shut-in immediately.
214855861 2014-1-14 0:00: PW No Violations 0.30
577303717 2016-6-21 0:00: PW No Violations 0.70

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1234691965 US-OH-106283 2014-04-10 Failure to legibly identify well
1285508938 US-OH-107916 2016-06-13 Well operation causing pollution and contamination
1285508938 US-OH-107917 2016-06-13 Failure to legibly identify well
1393509014 US-OH-111633 2014-11-17 Failure to register/obtain or maintain bond/insurance

For data sources see[9]

References