34-153-22699

Well Details

Well ID: 34-153-22699
Loading map...
Country: United States
State: Ohio
County: Summit
Municipality: Bath Township
Operator Name: TRANSCONTINENTAL OIL & GAS INC
Well Pad ID:
Farm/Lease Name: DAILY
License Status: Producing
License Date: 1990-12-19
Spud Date: 1991-04-29
Spud Drilling Contractor: MOHAWK DRLG
Final Drill Date: 1991-05-07
Well Total Depth: 3550.00 ft
Configuration: Vertical
Latitude: 41.150000
Longitude: -81.600000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Oil and Gas 1990-12-19 Issued Date 12/19/90 Expired Date 12/19/91 Acres 0032925 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 03550 Proposed Drill Depth 03550
Original Spud 1991-04-29 PERMIT EXPIRED.
Completed 1991-05-07 PERMIT EXPIRED.
Reached Total Depth 1991-05-07 PERMIT EXPIRED.
CO 1991-05-10 1249 CUTTER OIL CO GeoDate 12/19/90
Construction Permit Expires 1991-12-19 PERMIT EXPIRED.
Completion Report Received 1992-01-23 PERMIT EXPIRED.
Change of Owner 2011-12-20 Operator changed from 1249, CUTTER OIL CO to 4744, TRANSCONTINENTAL O & G
Record Last Modified 2017-02-15 PERMIT EXPIRED.

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
1997-06-29 3362 3449 0
3362 3449 0
2006-09-11 3416 3450 25
3416 3450 25
3362 3449 0

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
N2 0 250 Mscf 0
ACID 0 500 Gal 70000 FRAC W/2400 BW,700 SX SAND AND 250
H2O 0 2400 Bbl 0 ISIP 1100 PSI:

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1991 CUTTER OIL COMPANY 3743.00 828.00 145
1992 CUTTER OIL COMPANY 13941.00 1593.00 365
1993 CUTTER OIL COMPANY 10376.00 702.00 365
1994 CUTTER OIL COMPANY 9972.00 695.00 365
1995 CUTTER OIL COMPANY 6948.00 384.00 365
1996 CUTTER OIL COMPANY 4980.00 379.00 365
1997 CUTTER OIL COMPANY 3826.00 188.00 365
1998 CUTTER OIL COMPANY 3498.00 227.00 365
1999 CUTTER OIL COMPANY 2966.00 189.00 365
2000 CUTTER OIL COMPANY 2033.00 179.00 365
2001 CUTTER OIL COMPANY 1420.00 216.00 365
2002 CUTTER OIL COMPANY 1647.00 223.00 365
2003 CUTTER OIL COMPANY 1149.00 0.00 365
2004 CUTTER OIL COMPANY 0.00 110.00 365
2005 CUTTER OIL COMPANY 1859.00 183.00 365
2006 CUTTER OIL COMPANY 1930.00 87.00 365
2007 CUTTER OIL COMPANY 1497.00 202.00 365
2008 CUTTER OIL COMPANY 845.00 128.00 365
2009 CUTTER OIL COMPANY 320.00 139.00 365
2010 CUTTER OIL COMPANY 1132.00 86.00 365
2011 TRANSCONTINENTAL OIL & GAS INC 1206.00 125.00 365
2012 TRANSCONTINENTAL OIL & GAS INC 940.00 74.00 366
2013 TRANSCONTINENTAL OIL & GAS INC 591.00 54.00 365
2014 TRANSCONTINENTAL OIL & GAS INC 359.00 148.00 365
2015 TRANSCONTINENTAL OIL & GAS INC 516.00 120.00 365
2016 TRANSCONTINENTAL OIL & GAS INC 1050.00 113.00 365
2017 TRANSCONTINENTAL OIL & GAS INC 1080.00 54.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1991 CUTTER OIL COMPANY Brine 1234 145
1992 CUTTER OIL COMPANY Brine 351 365
1993 CUTTER OIL COMPANY Brine 212 365
1994 CUTTER OIL COMPANY Brine 172 365
1995 CUTTER OIL COMPANY Brine 178 365
1996 CUTTER OIL COMPANY Brine 131 365
1997 CUTTER OIL COMPANY Brine 128 365
1998 CUTTER OIL COMPANY Brine 117 365
1999 CUTTER OIL COMPANY Brine 190 365
2000 CUTTER OIL COMPANY Brine 176 365
2001 CUTTER OIL COMPANY Brine 118 365
2002 CUTTER OIL COMPANY Brine 224 365
2003 CUTTER OIL COMPANY Brine 80 365
2004 CUTTER OIL COMPANY Brine 0 365
2005 CUTTER OIL COMPANY Brine 160 365
2006 CUTTER OIL COMPANY Brine 62 365
2007 CUTTER OIL COMPANY Brine 120 365
2008 CUTTER OIL COMPANY Brine 50 365
2009 CUTTER OIL COMPANY Brine 85 365
2010 CUTTER OIL COMPANY Brine 89 365
2011 TRANSCONTINENTAL OIL & GAS INC Brine 54 365
2012 TRANSCONTINENTAL OIL & GAS INC Brine 37 366
2013 TRANSCONTINENTAL OIL & GAS INC Brine 62 365
2014 TRANSCONTINENTAL OIL & GAS INC Brine 51 365
2015 TRANSCONTINENTAL OIL & GAS INC Brine 55 365
2016 TRANSCONTINENTAL OIL & GAS INC Brine 61 365
2017 TRANSCONTINENTAL OIL & GAS INC Brine 33 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0000011531 Preliminary Restoration No Violations PASSED Y WITNESSED 6/26/91 INSPECTOR MARK MORELAND DATE 06/2619/91 DATA FROM OLD VAX INFO
11531 PL No Violations
1395670566 2014-03-14 UrbanProduction Wells Violations Noted I inspected this well on 3/4/2014. The lease road was graveled and passable for traffic. The tank battery consisted of a 210 Bbl. Stock tank, a 25 Bbl. Brine tank and a vertical separator.The dike was sufficent to contain the fluids in the tank battery. I found that the load lines were unlocked and outside the fencing . The north gate was unlocked allowing unrestricted access. The 210 Bbl. Stock tank was leaking at the welded seam at 10. It appeared that previous repairs were made on this tank. The well consisted of a Churchill model 40 pumping unit ran by electric. The standard pumping well head configuration was used and leak free at the time of my inspection. A domestic house outlet was connected to the wells casing. A small compressor was located inside the fencing with the well. A 55 gallon drum was located outside of the wells fencing and was full of some type of fluid. The access gate to the well was locked. The electric box was not locked. The gas sales line is above ground and crosses Yellow Creek stream on a bridge and presents a possible source of contamination due its position and construction. I spoke with the Operator ( Cal Marks of Transcontinental ) who said that since Dominion / EOG recently upgraded their gaslines it was possible to lay a line to them to sell the lease gas. In order to bring this well into compliance Transcontinental shall place locks on the loadlines, gates, electrical boxes and reroute, bury the gas salesline as to eliminate a possible source of pollution. The 210 Bbl. will either be satisfactorily and permanently repaired or replaced. The 55 gallon drum shall be emptied and if required for operations be moved inside of the fencing for the pump jack.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1395670566 US-OH-111697 2014-06-17 LOCKS
1395670566 US-OH-111698 2014-06-17 TANKS (a-i)
1395670566 US-OH-111699 2014-06-17 Failure to properly bury pipeline