X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-151-25204

Well Details

Well ID: 34-151-25204
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Nimishillen Township
Operator Name: BECK ENERGY CORPORATION
Well Pad ID:
Farm/Lease Name: BECK-SHANNON
License Status: Producing
License Date: 2000-12-01
Spud Date: 2001-01-05
Spud Drilling Contractor: PEP DRLG
Final Drill Date: 2001-01-10
Well Total Depth: 4966.00 ft
Configuration: Vertical
Latitude: 40.860000
Longitude: -81.290000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2000-12-01 1888 BECK ENERGY CORP Proposed Formation CLINTON Issued Date 12/1/00 Expired Date 12/1/01 6:00:00 AM
Original Spud 2001-01-05 RBDMS Rec
Completed 2001-01-10 RBDMS Rec
Reached Total Depth 2001-01-10 RBDMS Rec
Completion Report Received 2001-08-30 RBDMS Rec
Construction Permit Expires 2001-12-01 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2001-10-23 4736 4776 84
4736 4776 84
4736 4776 84

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 100000 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2001 BECK ENERGY CORPORATION 2772.00 1285.00 137
2002 BECK ENERGY CORPORATION 3815.00 1355.00 365
2003 BECK ENERGY CORPORATION 2387.00 857.00 365
2004 BECK ENERGY CORPORATION 1015.00 511.00 365
2005 BECK ENERGY CORPORATION 1099.00 496.00 365
2006 BECK ENERGY CORPORATION 477.00 313.00 365
2007 BECK ENERGY CORPORATION 964.00 409.00 365
2008 BECK ENERGY CORPORATION 1231.00 555.00 365
2009 BECK ENERGY CORPORATION 1289.00 434.00 365
2010 BECK ENERGY CORPORATION 1008.00 318.00 365
2011 BECK ENERGY CORPORATION 2158.00 465.00 365
2012 BECK ENERGY CORPORATION 2202.00 482.00 366
2013 BECK ENERGY CORPORATION 1201.00 307.00 365
2014 BECK ENERGY CORPORATION 1353.00 419.00 365
2015 BECK ENERGY CORPORATION 1562.00 229.00 365
2016 BECK ENERGY CORPORATION 1394.00 468.00 365
2017 BECK ENERGY CORPORATION 1641.00 433.00 365
2018 BECK ENERGY CORPORATION 1599.00 213.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2001 BECK ENERGY CORPORATION Brine 1062 137
2002 BECK ENERGY CORPORATION Brine 560 365
2003 BECK ENERGY CORPORATION Brine 110 365
2004 BECK ENERGY CORPORATION Brine 95 365
2005 BECK ENERGY CORPORATION Brine 85 365
2006 BECK ENERGY CORPORATION Brine 35 365
2007 BECK ENERGY CORPORATION Brine 100 365
2008 BECK ENERGY CORPORATION Brine 135 365
2009 BECK ENERGY CORPORATION Brine 70 365
2010 BECK ENERGY CORPORATION Brine 50 365
2011 BECK ENERGY CORPORATION Brine 160 365
2012 BECK ENERGY CORPORATION Brine 142 366
2013 BECK ENERGY CORPORATION Brine 41 365
2014 BECK ENERGY CORPORATION Brine 186 365
2015 BECK ENERGY CORPORATION Brine 41 365
2016 BECK ENERGY CORPORATION Brine 181 365
2017 BECK ENERGY CORPORATION Brine 121 365
2018 BECK ENERGY CORPORATION Brine 81 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0001288i67 2001-09-25 Preliminary Restoration No Violations Preliminary restoration approved , no violations at this time. Spud date : 01/05/01.
001288i460 2002-04-15 Preliminary Restoration No Violations Preliminary restoration approved at this time . No violations at this time .
0898695707 2017-08-16 Production Wells No Violations I did a status check inspection on this well. The well is equipped with a pumpjack with a gas motor. The tank battery consists of a steel production tank, a plastic brine vault, a horizontal separator and a meter. There is a domestic gas connection at the well. The well is legibly identified. There is material on location near the tank battery which may be used in building a dike around the tank battery. I spoke with Junior (Beck Energy) and he advised me the material is topping material for the dike. They still need to get the base material delivered. There are no compliamce issues noted at this time.
1288i460 2002-4-15 0:00: PL No Violations 0.50
1288i67 2001-9-25 0:00: PL No Violations 0.50
898695707 2017-8-16 0:00: PW No Violations 0.50
iDIAN00627 2001-09-25 Preliminary Restoration No Violations
iDIAN006278 2001-9-25 0:00: PL No Violations

For data sources see[9]

References