X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-151-25100

Well Details

Well ID: 34-151-25100
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Osnaburg Township
Operator Name: WILLIAM S MILLER INC
Well Pad ID:
Farm/Lease Name: SHEARER T B
License Status: Producing
License Date: 2003-03-31
Spud Date: 2003-09-15
Spud Drilling Contractor: ADVENT DRLG
Final Drill Date: 2003-09-21
Well Total Depth: 5220.00 ft
Configuration: Vertical
Latitude: 40.750000
Longitude: -81.200000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 1998-06-15 146 FOLTZ & FOLTZ ENTP Proposed Formation CLINTON Issued Date 6/15/1998 Expired Date 6/15/1999 6:00:00 AM
APP 2003-03-31 Proposed Formations:CLINTON, Issued Date:3/31/2003, Expired Date:3/30/2004 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Inspector Comments Cement Job 2003-09-15 30 E towards Robertsville; turn right on Mapleton, cross R.R. tracks; left on Deuble, go approx. 0.3 mi., access on right.Cement Ticket Notes Inspector Reporting CLAUS DAVID
Original Spud 2003-09-15 RBDMS Rec
Completed 2003-09-21 RBDMS Rec
Reached Total Depth 2003-09-21 RBDMS Rec
Construction Permit Expires 2004-03-30 RBDMS Rec
Completion Report Received 2004-10-06 RBDMS Rec
Change of Owner 2017-12-20 Operator changed from 146, FOLTZ & FOLTZ LTD PARTNERSHIP to 2512, WILLIAM S MILLER INC
Record Last Modified 2017-12-20 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2004-11-18 5055 5160 37
5055 5160 37
5055 5160 37

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 0 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2004 FOLTZ & FOLTZ LTD PARTNERSHIP 2573.00 1439.00 365
2005 FOLTZ & FOLTZ LTD PARTNERSHIP 992.00 751.00 365
2006 FOLTZ & FOLTZ LTD PARTNERSHIP 379.00 373.00 365
2007 FOLTZ & FOLTZ LTD PARTNERSHIP 188.00 415.00 365
2008 FOLTZ & FOLTZ LTD PARTNERSHIP 385.00 247.00 365
2009 FOLTZ & FOLTZ LTD PARTNERSHIP 364.00 121.00 365
2010 FOLTZ & FOLTZ LTD PARTNERSHIP 131.00 235.00 365
2011 FOLTZ & FOLTZ LTD PARTNERSHIP 1012.00 119.00 365
2012 FOLTZ & FOLTZ LTD PARTNERSHIP 1840.00 128.00 366
2013 FOLTZ & FOLTZ LTD PARTNERSHIP 1995.00 0.00 365
2014 FOLTZ & FOLTZ LTD PARTNERSHIP 411.00 151.00 365
2015 FOLTZ & FOLTZ LTD PARTNERSHIP 317.00 0.00 365
2016 FOLTZ & FOLTZ LTD PARTNERSHIP 1090.00 239.00 365
2017 FOLTZ & FOLTZ LTD PARTNERSHIP 922.00 161.00 365
2018 WILLIAM S MILLER INC 1330.00 168.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2004 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 962 365
2005 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 375 365
2006 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 75 365
2007 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
2008 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 285 365
2009 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 288 365
2010 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 150 365
2011 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 80 365
2012 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 120 366
2013 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
2014 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
2015 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 80 365
2016 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
2017 FOLTZ & FOLTZ LTD PARTNERSHIP Brine 0 365
2018 WILLIAM S MILLER INC Brine 390 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1075574788 2017-10-4 0:00: PW No Violations
-1590675702 2006-9-20 0:00: PL No Violations
-818550519 2005-11-23 0:00 PL No Violations
-870904979 2006-1-31 0:00: PW No Violations
-94553622 2017-5-4 0:00:0 PW No Violations 0.50
0094553622 2017-05-04 Production Wells No Violations I conducted a status check inspection on this well. The well is equipped with a pumpjack with an electric motor. The diked tank battery consist of two 210 barrel tanks, a steel brine tank, two vertical separators and a meter. There is a domestic gas connection at the tank battery. The tank battery is shared with well # 25736. The well is legibly identified. No compliance issues are noted at this time.
0818550519 2005-11-23 Preliminary Restoration No Violations Violations still exist.
0870904979 2006-01-31 Production Wells No Violations Stock tanks are still unpainted and there is no I.D. sign.
1075574788 2017-10-04 Production Wells No Violations I did a status check inspection on this well. The well is equipped with a pumpjack. The tank battery consists of two steel production tanks, a steel brine tank, two vertical separators and a meter. There is a domestic gas connection at the tank battery. The tank battery is shared with well # 151-25756. The well is identified at the tank battery. I called and spoke with Mr. Foltz (Foltz & Foltz) he advised me he would have identification at the well by 10-06-2017. A follow-up inspection will be done around 10-20-2017.
1113068678 2005-04-08 Preliminary Restoration Violations Noted The preliminary restoration is overdue; the flowline is not completely buried; stock tanks are not painted; there is no I.D. on the stock tanks or at the wellhead. Call Bob Foltz (cell # 330-323-6031).
1590675702 2006-09-20 Preliminary Restoration No Violations The well is completed as a pumping well. The location is reclaimed. The wellhead and the tank battery (2-210 bbl oil stock tanks, 1-100 bbl brine tank) have the correct I.D. signs. Preliminary Restoration is PASSED.
1741809929 2006-03-23 Preliminary Restoration No Violations The preliminary restoration is still overdue; the flowline is not completely buried; stock tanks are not painted; there is no I.D. on the stock tanks or at the wellhead. Call Bob Foltz (cell # 330-323-6031).
2037651948 2004-07-06 Preliminary Restoration No Violations Well was drilled 9-16-2003. Well is in production. Site has not been reclaimed. Tank battery has not been painted. No I.D. Did not pass preliminary restoration.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1113068678 US-OH-102848 2005-04-09 Failure to restore land surface within 9 mos. (CHANGE) (REPLACE)

For data sources see[9]

References