X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-151-24188

Well Details

Well ID: 34-151-24188
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Nimishillen Township
Operator Name: BECK ENERGY CORPORATION
Well Pad ID:
Farm/Lease Name: GEORGE
License Status: Producing
License Date: 1985-09-04
Spud Date: 1985-11-09
Spud Drilling Contractor: CUBBY DRLG
Final Drill Date: 1985-11-12
Well Total Depth: 4892.00 ft
Configuration: Vertical
Latitude: 40.850000
Longitude: -81.300000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1985-09-04 1888 BECK ENERGY CORP GeoDate 9/4/85
Oil and Gas 1985-09-04 Issued Date 9/4/85 Expired Date 3/3/86 Acres 0040000 Tool Type RTAF Proposed Formation CLINTON Proposed Depth 04892 Proposed Drill Depth 04892
Original Spud 1985-11-09
Completed 1985-11-12
Reached Total Depth 1985-11-12
Completion Report Received 1986-02-12
Construction Permit Expires 1986-03-03
Record Last Modified 2017-02-15

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4689 4748 30
4689 4748 30
4689 4748 30

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 96500 Gal 50000 FRAC;H2O,SAND

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1986 BECK ENERGY CORPORATION 9653.00 1694.00 299
1987 BECK ENERGY CORPORATION 10827.00 1432.00 365
1988 BECK ENERGY CORPORATION 8739.00 1074.00 365
1989 BECK ENERGY CORPORATION 7047.00 693.00 365
1990 BECK ENERGY CORPORATION 6025.00 681.00 365
1991 BECK ENERGY CORPORATION 5873.00 685.00 365
1992 BECK ENERGY CORPORATION 4956.00 590.00 365
1993 BECK ENERGY CORPORATION 4644.00 581.00 365
1994 BECK ENERGY CORPORATION 4240.00 308.00 365
1995 BECK ENERGY CORPORATION 3270.00 303.00 365
1996 BECK ENERGY CORPORATION 2753.00 371.00 365
1997 BECK ENERGY CORPORATION 2209.00 279.00 365
1998 BECK ENERGY CORPORATION 1747.00 229.00 334
1999 BECK ENERGY CORPORATION 1975.00 283.00 0
2000 BECK ENERGY CORPORATION 2393.00 328.00 0
2001 BECK ENERGY CORPORATION 2188.00 222.00 365
2002 BECK ENERGY CORPORATION 2193.00 233.00 365
2003 BECK ENERGY CORPORATION 1830.00 209.00 365
2004 BECK ENERGY CORPORATION 1589.00 103.00 365
2005 BECK ENERGY CORPORATION 614.00 138.00 365
2006 BECK ENERGY CORPORATION 1326.00 74.00 365
2007 BECK ENERGY CORPORATION 1190.00 191.00 365
2008 BECK ENERGY CORPORATION 997.00 123.00 365
2009 BECK ENERGY CORPORATION 982.00 217.00 365
2010 BECK ENERGY CORPORATION 528.00 75.00 365
2011 BECK ENERGY CORPORATION 529.00 147.00 365
2012 BECK ENERGY CORPORATION 430.00 145.00 366
2013 BECK ENERGY CORPORATION 616.00 74.00 365
2014 BECK ENERGY CORPORATION 287.00 145.00 365
2015 BECK ENERGY CORPORATION 170.00 71.00 365
2016 BECK ENERGY CORPORATION 112.00 72.00 365
2017 BECK ENERGY CORPORATION 358.00 69.00 365
2018 BECK ENERGY CORPORATION 415.00 66.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1986 BECK ENERGY CORPORATION Brine 1200 299
1987 BECK ENERGY CORPORATION Brine 825 365
1988 BECK ENERGY CORPORATION Brine 525 365
1989 BECK ENERGY CORPORATION Brine 370 365
1990 BECK ENERGY CORPORATION Brine 375 365
1991 BECK ENERGY CORPORATION Brine 395 365
1992 BECK ENERGY CORPORATION Brine 320 365
1993 BECK ENERGY CORPORATION Brine 290 365
1994 BECK ENERGY CORPORATION Brine 220 365
1995 BECK ENERGY CORPORATION Brine 140 365
1996 BECK ENERGY CORPORATION Brine 325 365
1997 BECK ENERGY CORPORATION Brine 140 365
1998 BECK ENERGY CORPORATION Brine 175 334
1999 BECK ENERGY CORPORATION Brine 240
2000 BECK ENERGY CORPORATION Brine 385
2001 BECK ENERGY CORPORATION Brine 140 365
2002 BECK ENERGY CORPORATION Brine 175 365
2003 BECK ENERGY CORPORATION Brine 210 365
2004 BECK ENERGY CORPORATION Brine 70 365
2005 BECK ENERGY CORPORATION Brine 105 365
2006 BECK ENERGY CORPORATION Brine 105 365
2007 BECK ENERGY CORPORATION Brine 70 365
2008 BECK ENERGY CORPORATION Brine 245 365
2009 BECK ENERGY CORPORATION Brine 280 365
2010 BECK ENERGY CORPORATION Brine 105 365
2011 BECK ENERGY CORPORATION Brine 180 365
2012 BECK ENERGY CORPORATION Brine 70 366
2013 BECK ENERGY CORPORATION Brine 150 365
2014 BECK ENERGY CORPORATION Brine 100 365
2015 BECK ENERGY CORPORATION Brine 82 365
2016 BECK ENERGY CORPORATION Brine 40 365
2017 BECK ENERGY CORPORATION Brine 91 365
2018 BECK ENERGY CORPORATION Brine 125 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-125354658 2017-3-29 0:00: PW No Violations 0.70
0000PL5205 Preliminary Restoration No Violations Preliminary Restoration done information from Data Point
0125354658 2017-03-29 Production Wells No Violations I conducted a compliance notice follow-up inspection on this well. The well is legibly identified and the violation is passed. The owner has added fencing and locked gates to the well and tank battery. Also, spark arrestor and charcoal filter were added to the tanks.
0845692295 2017-02-28 Production Wells Violations Noted Tom Hill (ODNR Regional Supervisor) was in accompaniment. I conducted a status check and a complaint follow-up inspection for complaint #5535 on this well. The complaint is for the occasional odor of gas and the well is located in an urban township. The well is equipped with a pumpjack with an electric motor. The well is not fenced, the electric box is not locked and there is no pulley guard. The diked tank battery consists of two 100 barrel tanks, two horizontal separators, two inground concrete brine vaults and two meters. The tank battery is not fenced and the tank has no lightning arrestor nor an activated charcoal filter on the vent stack. The tank battery is shared with well # 24170. The well is legibly identified at the tank battery but not at the well. The well needs to be identified since there is a shared tank battery. It is requested at this time that the operator make the necessary changes to the well and the tank battery to meet the Urban Well requirements as outlined in Ohio Administrative Code (OAC) 1501:9-9-05.
845692295 2017-2-28 0:00: PW No Violations 0.70
PL5205 PL No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0845692295 US-OH-129630 2017-07-24 9-9-05(A)10 Failure to legibly identify well

For data sources see[9]

References