34-151-23429

Well Details

Well ID: 34-151-23429
Loading map...
Country: United States
State: Ohio
County: Stark
Municipality: Paris Township
Operator Name: VIKING RESOURCES LLC
Well Pad ID:
Farm/Lease Name: ROHRER UNIT
License Status: Plugged and Abandoned
License Date: 2012-12-19
Spud Date: 1981-06-25
Spud Drilling Contractor:
Final Drill Date: 1981-02-06
Well Total Depth: 5347.00 ft
Configuration: Vertical
Latitude: 40.790000
Longitude: -81.150000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1980-12-31 198 VIKING RESOURCES CORP GeoDate 12/31/80
Oil and Gas 1980-12-31 Issued Date 12/31/80 Expired Date Acres 0080800 Tool Type RTA Proposed Formation CLINTON Proposed Depth 00000 Proposed Drill Depth 00000
Reached Total Depth 1981-02-06
Original Spud 1981-06-25
Completed 1981-06-29
Completion Report Received 1981-10-08
APP 2012-12-19 Proposed Formations:CLINTON, Issued Date:12/19/2012, Expired Date:12/19/2014 12:00:00 PM, Drilling unit acres:80.89, Proposed Well Type:OG, Proposed Well Class:
Plugged/Abandoned 2014-10-13
Construction Permit Expires 2014-12-19
Record Last Modified 2015-01-14

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 5186 5192 8
5186 5192 8
5186 5192 8

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 47100 Gal 50000

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 VIKING RESOURCES LLC 477.00 568.00 0
1988 VIKING RESOURCES LLC 21.00 360.00 365
1989 VIKING RESOURCES LLC 75.00 650.00 365
1990 VIKING RESOURCES LLC 0.00 332.00 356
1991 VIKING RESOURCES LLC 0.00 284.00 344
1992 VIKING RESOURCES LLC 0.00 248.00 304
1994 VIKING RESOURCES LLC 0.00 260.00 365
1995 VIKING RESOURCES LLC 0.00 297.00 0
1996 VIKING RESOURCES LLC 0.00 250.00 0
1997 VIKING RESOURCES LLC 0.00 245.00 0
1998 VIKING RESOURCES LLC 0.00 200.00 365
2000 RESOURCE AMERICA INC 0.00 203.00 365
2001 VIKING RESOURCES LLC 0.00 56.00 365
2002 VIKING RESOURCES LLC 0.00 0.00 365
2003 VIKING RESOURCES LLC 0.00 0.00 365
2004 VIKING RESOURCES LLC 0.00 0.00 365
2005 VIKING RESOURCES LLC 0.00 0.00 365
2006 VIKING RESOURCES LLC 0.00 0.00 365
2007 VIKING RESOURCES LLC 0.00 0.00 365
2008 VIKING RESOURCES LLC 0.00 0.00 366
2009 VIKING RESOURCES LLC 0.00 0.00 365
2010 VIKING RESOURCES LLC 0.00 0.00 365
2011 VIKING RESOURCES LLC 0.00 0.00 0
2012 VIKING RESOURCES LLC 0.00 0.00 0
2013 VIKING RESOURCES LLC 0.00 0.00 0

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 VIKING RESOURCES LLC Brine 0 0
1988 VIKING RESOURCES LLC Brine 135 365
1989 VIKING RESOURCES LLC Brine 191 365
1990 VIKING RESOURCES LLC Brine 80 356
1991 VIKING RESOURCES LLC Brine 75 344
1992 VIKING RESOURCES LLC Brine 60 304
1994 VIKING RESOURCES LLC Brine 130 365
1995 VIKING RESOURCES LLC Brine 83 0
1996 VIKING RESOURCES LLC Brine 98 0
1997 VIKING RESOURCES LLC Brine 60 0
1998 VIKING RESOURCES LLC Brine 60 365
2000 RESOURCE AMERICA INC Brine 0 365
2001 VIKING RESOURCES LLC Brine 0 365
2002 VIKING RESOURCES LLC Brine 0 365
2003 VIKING RESOURCES LLC Brine 0 365
2004 VIKING RESOURCES LLC Brine 40 365
2005 VIKING RESOURCES LLC Brine 0 365
2006 VIKING RESOURCES LLC Brine 0 365
2007 VIKING RESOURCES LLC Brine 0 365
2008 VIKING RESOURCES LLC Brine 0 366
2009 VIKING RESOURCES LLC Brine 0 365
2010 VIKING RESOURCES LLC Brine 0 365
2011 VIKING RESOURCES LLC Brine 0
2012 VIKING RESOURCES LLC Brine 0 0
2013 VIKING RESOURCES LLC Brine 40 0

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
0170460587 2014-03-03 Production Wells No Violations I was on location to follow up to a compliance notice written 10/10/2012. My inspection found the wellhead was equipped for a pumping unit. The pumping unit was on-site but did not have belts installed for the motor and it is unknown if electrical power is available for the unit. The identification sign was found near the wellhead but difficult to read. The area around the wellhead is overgrown with vegetation. I did not detect a gas odor and there were no fluids leaking from the wellhead. All valves are closed. The pressure gauge was found on the ground. The tank battery consists of one 210 barrel stock tank and an earthen dike that was overgrown with vegetation. There was no brine storage tank, no separator or chart present. Production numbers have not been reported for this well since 2001. This well is not eligible for temporary inactive status and must be plugged. A permit to plug this well is currently in hand and expires 12/19/2014. I contacted Atlas Energy and they stated that the AFE for this well is currently being approved at their Texas office and that Nicks Well Plugging will be on location when available in the coming months. This well must be plugged.
1073743951 2016-09-26 Final Restoration No Violations I conducted a final resoration inspection on this well. The fianl restoration cannot be passed at this time. A landowner waiver is still needed for the lease road and any flowlines or production lines which may have been left. I contacted Dan Rexroad (Atlas/ Viking) via e-mail on 10-5-2016 about getting a landowner waiver.
1349286393 2012-10-02 Production Wells Violations Noted I received a phone call from Edward Zwick on September 18, 2012 regarding the Rohrer Unit 1 (34-151-2-3430-00-00) & Rohrer Unit 2 (34-151-2-3429-00-00) wells. Mr. Zwick is concerned with the current condition of the wells and the lack of reported production. I inspected the Rohrer Unit 2 (34-151-2-3429-00-00) well on October 2, 2012 and found the wellhead was equipped for a pumping unit. The pumping unit was on-site but did not have belts installed for the motor and it is unknown if electrical power is available for the unit. The identification sign was found near the wellhead but difficult to read. The area around the wellhead is overgrown with vegetation. I did not detect a gas odor and there were no fluids leaking from the wellhead. All valves are closed. The pressure gauge was found on the ground. This well shares a tank battery with the Rohrer Unit 1 (34-151-2-3430-00-00). The tank battery consists of one 210 barrel stock tank and an earthen dike that was overgrown with vegetation. There was no brine storage tank, no separator or chart present. Production numbers have not been reported for this well since 2001. This well is not eligible for temporary inactive status and must be plugged.
170460587 2014-3-3 0:00:0 PW No Violations
1902725282 2014-10-08 Plug / Plug Back No Violations I was on location to check the status of Nicks Well Plugging pulling rods and tubing from this well to prepare it for plugging. The rods and tubing are hung up in the well approximately 1000 below surface. It is believed that there is a salt ring holding the tubing and rods in the well. The well has been pumped on with freshwater and shut in and will be left overnight in an attempt to dissolve the salt ring and free up the tubing and the rods.

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1349286393 US-OH-110116 2012-12-26 Failure to legibly identify well
1349286393 US-OH-110117 2012-12-26 Well shall be plugged
1349286393 US-OH-110118 2012-12-26 Nonproduction; well shall be plugged or placed in temporary inactive status

For data sources see[9]

References