If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-151-22459 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":40.79,"lon":-81.23,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Stark | |
Municipality: Osnaburg Township | |
Operator Name: BRINEAWAY INC | |
Well Pad ID: | |
Farm/Lease Name: WALKER J& E | |
License Status: Active Injection | |
License Date: 1999-12-09 | |
Spud Date: 1974-01-02 | |
Spud Drilling Contractor: SERVICE RIG | |
Final Drill Date: 1974-01-10 | |
Well Total Depth: 5290.00 ft | |
Configuration: Vertical | |
Latitude: 40.790000 | |
Longitude: -81.230000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1974-01-02 | ONLY INJECTING INTO THE CLINTON/ MEDINA. PB-12/11/99, CONV ERT 9-3-94, |
Reached Total Depth | 1974-01-10 | ONLY INJECTING INTO THE CLINTON/ MEDINA. PB-12/11/99, CONV ERT 9-3-94, |
CO | 1994-08-31 | 2328 BRINEAWAY INC GeoDate 8/31/94 |
Conversion to Injector | 1994-08-31 | |
Salt Water Injection Well | 1994-08-31 | Issued Date 8/31/94 Expired Date 8/31/95 Acres 0071910 Tool Type NT Proposed Formation NEWBURG/CLINTON Proposed Depth 05290 Proposed Drill Depth 05290 |
Storage Well | 1994-08-31 | Issued Date 8/31/94 Expired Date 8/31/95 Acres 0071910 Tool Type NT Proposed Formation NEWBURG/CLINTON Proposed Depth 05290 Proposed Drill Depth 05290 |
CO | 1994-11-14 | 139 MB OPERATING CO INC GeoDate 7/27/73 |
Completed | 1994-11-15 | ONLY INJECTING INTO THE CLINTON/ MEDINA. PB-12/11/99, CONV ERT 9-3-94, |
First Injection | 1994-11-24 | ONLY INJECTING INTO THE CLINTON/ MEDINA. PB-12/11/99, CONV ERT 9-3-94, |
Completion Report Received | 1995-09-01 | ONLY INJECTING INTO THE CLINTON/ MEDINA. PB-12/11/99, CONV ERT 9-3-94, |
APP | 1999-12-09 | Proposed Formations:NEWBURG, Issued Date:12/9/99, Expired Date:12/8/00 6:00:00 AM, Drilling unit acres:71.91, Proposed Well Type:SWD, Proposed Well Class:SWIW |
Plugged Back | 1999-12-11 | ONLY INJECTING INTO THE CLINTON/ MEDINA. PB-12/11/99, CONV ERT 9-3-94, |
Annulus Pressure Monitoring Approved | 2000-02-01 | ONLY INJECTING INTO THE CLINTON/ MEDINA. PB-12/11/99, CONV ERT 9-3-94, |
Construction Permit Expires | 2000-12-08 | ONLY INJECTING INTO THE CLINTON/ MEDINA. PB-12/11/99, CONV ERT 9-3-94, |
Last Compliance Report | 2015-05-20 | ONLY INJECTING INTO THE CLINTON/ MEDINA. PB-12/11/99, CONV ERT 9-3-94, |
Record Last Modified | 2017-02-15 | ONLY INJECTING INTO THE CLINTON/ MEDINA. PB-12/11/99, CONV ERT 9-3-94, |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2000-05-08 | 5107 | 5115 | 1 |
2000-05-08 | 5106 | 5166 | 0 |
5106 | 5166 | 0 | |
4740 | 4910 | 0 | |
5149 | 5153 | 3 | |
5107 | 5115 | 1 | |
5119 | 5131 | 1 | |
5161 | 5165 | 2 | |
4740 | 4910 | 0 | |
2000-05-08 | 4740 | 4910 | 0 |
2000-05-08 | 5161 | 5165 | 2 |
2000-05-08 | 5149 | 5153 | 3 |
2000-05-08 | 5119 | 5131 | 1 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
0 | 0 | 0 | 100 SHOTS | |||
H2O | 0 | 148000 Gal | 0 | ALSO 53,000 LBS OF 20/40 SAND USED. |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | QUAKER STATE OIL REF CORP | 0.00 | 495.00 | 0 |
1985 | QUAKER STATE OIL REF CORP | 0.00 | 488.00 | 365 |
1986 | QUAKER STATE OIL REF CORP | 0.00 | 312.00 | 365 |
1987 | QUAKER STATE OIL REF CORP | 0.00 | 346.00 | 365 |
1988 | QUAKER STATE OIL REF CORP | 0.00 | 202.00 | 365 |
1989 | QUAKER STATE OIL REF CORP | 0.00 | 127.00 | 365 |
1990 | PETROCON INC | 0.00 | 315.00 | 365 |
1991 | PETROCON INC | 0.00 | 321.00 | 365 |
1992 | PETROCON INC | 0.00 | 284.00 | 365 |
1993 | PETROCON INC | 0.00 | 228.00 | 365 |
1994 | PETROCON INC | 0.00 | 117.00 | 212 |
1995 | PETROCON INC | 0.00 | 0.00 | 0 |
1996 | PETROCON INC | 0.00 | 48.00 | 240 |
1997 | PETROCON INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | QUAKER STATE OIL REF CORP | Brine | 0 | 0 |
1985 | QUAKER STATE OIL REF CORP | Brine | 405 | 365 |
1986 | QUAKER STATE OIL REF CORP | Brine | 140 | 365 |
1987 | QUAKER STATE OIL REF CORP | Brine | 183 | 365 |
1988 | QUAKER STATE OIL REF CORP | Brine | 160 | 365 |
1989 | QUAKER STATE OIL REF CORP | Brine | 58 | 365 |
1990 | PETROCON INC | Brine | 310 | 365 |
1991 | PETROCON INC | Brine | 202 | 365 |
1992 | PETROCON INC | Brine | 191 | 365 |
1993 | PETROCON INC | Brine | 75 | 365 |
1994 | PETROCON INC | Brine | 29 | 212 |
1995 | PETROCON INC | Brine | 0 | 0 |
1996 | PETROCON INC | Brine | 3 | 240 |
1997 | PETROCON INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1075187773 | 2016-7-20 0:00: | SW | No Violations | |
-1161519752 | 2020-4-16 0:00: | SW | No Violations | 0.50 |
-1298921626 | 2004-9-21 0:00: | SW | No Violations | |
-1424291865 | 2013-9-27 0:00: | SW | No Violations | |
-1480850139 | 2004-6-22 0:00: | SW | No Violations | |
-1547241550 | 2008-6-12 0:00: | SW | No Violations | |
-1561367699 | 2005-6-28 0:00: | SW | No Violations | |
-1563059674 | 2019-5-15 0:00: | SW | No Violations | 1.50 |
-1598410388 | 2009-5-28 0:00: | SW | No Violations | |
-1699967759 | 2009-9-2 0:00:0 | SW | No Violations | |
-1716866321 | 2010-9-7 0:00:0 | SW | No Violations | |
-1747174095 | 2008-9-25 0:00: | SW | No Violations | |
-1757562614 | 2016-3-8 0:00:0 | SW | No Violations | |
-2051359983 | 2012-7-25 0:00: | SW | No Violations | |
-2052225348 | 2014-9-25 0:00: | SW | No Violations | |
-2068766466 | 2008-12-17 0:00 | SW | No Violations | |
-222902864 | 2015-4-6 0:00:0 | SW | No Violations | |
-246336154 | 2019-8-7 0:00:0 | SW | No Violations | 0.80 |
-447185550 | 2007-3-13 0:00: | SW | No Violations | |
-477930995 | 2006-3-2 0:00:0 | SW | No Violations | |
-512509416 | 2007-9-26 0:00: | SW | No Violations | |
-514428483 | 2016-3-14 0:00: | SW | No Violations | |
-517988749 | 2017-12-20 0:00 | SW | No Violations | 0.80 |
-532564670 | 2002-10-16 0:00 | SW | No Violations | 1.00 |
-705022291 | 2006-8-30 0:00: | SW | No Violations | |
-745198208 | 2014-12-29 0:00 | SW | No Violations | |
-751434714 | 2016-6-22 0:00: | SW | No Violations | |
-756168453 | 2018-12-13 0:00 | SW | No Violations | 0.50 |
-979894411 | 2014-3-19 0:00: | SW | No Violations | |
000UIC1659 | 1997-05-05 | Salt Water Injection Well | No Violations | 1501: 9-3-07 (D) EXCEED MAX.INJ. PSI |
000UIC1660 | 1997-05-05 | Salt Water Injection Well | No Violations | 1509.03 RULES & REGULATIONS |
000UIC1749 | 1999-01-29 | Salt Water Injection Well | No Violations | 1509.22 CONSTRUCTION |
001288i268 | 2002-01-23 | Salt Water Injection Well | No Violations | Injection : 800 ; Annulus : 0 ; Last inspection on 12 / 17 01 . No violations at this time . |
001288i328 | 2002-03-05 | Salt Water Injection Well | No Violations | Injection : 410 ; Annulus : 0 ; Last inspection : 01 / 23 / 02 . No violations at this time . |
0041781728 | 2004-09-24 | Salt Water Injection Well | No Violations | NO VIOLATIONS. The system was not running at the time of the inspection. |
0071225919 | 2018-08-29 | Salt Water Injection Well | No Violations | I found the injection well not in production on the day of my inspection. Identification signs are posted. The access road gate to the facility was closed. |
0076306352 | 2003-05-22 | Salt Water Injection Well | No Violations | Facility is under repair. Well is not operating. |
0124990549 | 2017-03-27 | Salt Water Injection Well | Violations Noted | The well was found operating over the maximum allowable injection pressure. Paul Shaw was notified. He was instructed to shut down the pump and adjust the pressure shut-off switch accordingly. |
0222902864 | 2015-04-06 | Salt Water Injection Well | No Violations | A redressed Halliburton R-4 packer was set in compression at 5014 feet. A mechanical integrity test (MIT) was performed on the well. A pressure of 1200 psi. was placed on the tubing-casing annulus. The MIT passed without a loss, during the fifteen minute test period. |
0297755979 | 2007-12-19 | Salt Water Injection Well | No Violations | The injection pump was not running at the time of the inspection. There were no violations at the wellhead or at the multiple brine tank facility. |
0367881384 | 2005-02-04 | Salt Water Injection Well | No Violations | The system was running at the time of the inspection. NO VIOLATIONS. |
0415431848 | 2007-06-27 | Salt Water Injection Well | No Violations | The system was not running at the time of the inspection. The injection pump is under repair. There were no violations at the wellhead or at the brine tank. The lease road has been heavily eroded and needs to be graded. |
0447185550 | 2007-03-13 | Salt Water Injection Well | No Violations | The facility is idle. There is no injection pump. |
0477930995 | 2006-03-02 | Salt Water Injection Well | No Violations | The injection pump was running at the time of the inspection. No Violations at WH or at TB. |
0509665470 | 2017-05-09 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. The pump was operating at the time. The tanks and lines had no visible leaks.
No violations were found. |
0512509416 | 2007-09-26 | Salt Water Injection Well | No Violations | The injection pump was not running at the time of the inspection. There were no violations at the wellhead or at the brine tanks. |
0514428483 | 2016-03-14 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. The pump was not operating at the time. Pressure differential between the tubing and annulus was increasing, indicating mechanical integrity. There were no violations found at the time. |
0517988749 | 2017-12-20 | Salt Water Injection Well | No Violations | I found the injection and facility in good repair on the day of my inspection. I observed no leaks or spills. An identification sign is posted at the facility and well. The steel structure covering the storage tank and well is in good condition. There are no violations at this time. |
0532564670 | 2002-10-16 | Salt Water Injection Well | No Violations | Routine inspection revealed no violations at this time . The injection pump is apart for repairs at this time . They are also in the process of removing the storage tank from inside the dike at the wellhead . They are going to replace the liner inside the dike . Didnt check the injection pressure since the pump was apart and the wellhead partially disassembled . |
0611832726 | 2015-03-31 | Salt Water Injection Well | No Violations | The well operation was suspended by the company, in response to suspected mechanical integrity failure. The Division was notified on March 23, 2015. The well owner is current waiting for a service rig to become available. |
0624105809 | 2010-12-17 | Salt Water Injection Well | No Violations | The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the brine tank battery. The electric motor was running, but the injection pump was not. The injection pump belt was being eroded by the spinning electric motor. I called Paul Shaw and shut off the power supply to the electric motor. |
0652468891 | 2018-03-26 | Salt Water Injection Well | No Violations | I was on location to witness Brineaway acid treat the injection well. Greg New of Brineaway, Petroset, and a D P Operating brine truck (UIC #25-282) was on location. Petroset pumped 555 gallons of acid at 15% HCL, 5 gallons of 50% Citric Acid solution, and 250 gallons of fresh water spacer followed by displacing the fluids with 20 bbl. of fresh water. I observed no issues during the treatment process. |
0705022291 | 2006-08-30 | Salt Water Injection Well | No Violations | The system was running at the time of the inspection. There were no violations at the wellhead or at the tank battery. |
0745198208 | 2014-12-29 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. The well was found shut-in. There were no violations at the time of inspection. |
0751434714 | 2016-06-22 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. Pressure readings were taken, while the pump was operating. There were no violations found at the time. |
0756168453 | 2018-12-13 | Salt Water Injection Well | No Violations | I found the injection well not in operation on the day of my inspection. Identification signs are posted. I observed no leaks or spills in or around the facility and injection well. |
0765486711 | 2008-03-20 | Salt Water Injection Well | No Violations | The injection pump was running at the time of the inspection. There were no violations at the wellhead or at the multiple brine tank facility. |
0796436419 | 2013-06-25 | Salt Water Injection Well | No Violations | My inspection of the well and surface facility found no violations. |
0879113065 | 2013-12-27 | Salt Water Injection Well | No Violations | There were no violations found at the time of inspection. |
0881867059 | 2018-07-19 | Salt Water Injection Well | No Violations | I found the injection well not operating on the day of my inspection. Identification sign is posted. I observed no leaks or spills. There was a facility operator on location. The pump house is in good working order. |
0892500069 | 2015-05-29 | Salt Water Injection Well | No Violations | The well and surface facility were inspected. There were no violations found at the time of inspection. |
0922563185 | 2018-03-07 | Salt Water Injection Well | No Violations | I was on location to inspect the injection well and facility. I found the well not operating on the day of my inspection. There proper identification sign is posted. There are no violations at this time. |
0952903738 | 2005-11-14 | Salt Water Injection Well | No Violations | The system was running at the time of the inspection. Stock tank and WH have been painted. Informed Craig (Dorfman) that a new I.D. sign must be posted. |
0979894411 | 2014-03-19 | Salt Water Injection Well | No Violations | No violations were found at the time of inspection. |
1069502476 | 2009-12-04 | Salt Water Injection Well | No Violations | The injection system was running at the time of the inspection. There were no violations at the wellhead or at the brine tank battery. |
1075187773 | 2016-07-20 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
1078163436 | 2004-03-01 | Salt Water Injection Well | No Violations | A new plastic pit liner has been installed in the earthen pit. The system was not connected. NO VIOLATIONS. |
1085057974 | 2004-05-19 | Salt Water Injection Well | No Violations | Ran a newly rebuilt R-4 packer with a 9.55 tail pipe on 169 jts of used 2-3/8 upset tbg (tbg was steam cleaned and pressure tested on site). Used the same string of tbg that was in the well (see tbg tally dated 2-1-2000). Universal Well Services mixed and pumped 15 gallons of AnnHib with fresh water to load the annulus. The R-4 packer was set in compression (9,000 lbs) at a depth of 5085.50 . Universal pressured up on the annulus for the MIT.
Tried 3 MITs at 1250 psi. All failed. Tests were witnessed by Paul Shaw and Greg New of Dorfman. Dorfman will test the 4-1/2 csg for leaks at a later date. Old perforating info: 3-1/2 strip jet shots; .52 entry; 90 shots from 5110-5160. |
1085640085 | 2014-06-24 | Salt Water Injection Well | No Violations | A valve was stuck shut on the tubing, which will need replaced. No violations were found. |
1088558445 | 2004-06-29 | Salt Water Injection Well | No Violations | Conducted an MIT. Universal Well Services mixed and pumped 20 gallons of AnnHib with fresh water to load the annulus. The R-4 packer was set in compression (10,000 lbs) at a depth of 5041 (see tbg tally dated 2-1-2000 and subtract 1 joint). Universal pressured up to 1400 psi on the annulus. Pressure held at 1400 psi for 18 minutes. MIT PASSED. Test was witnessed by Paul Shaw of Dorfman. I called Tom Tomastik and informed him of the results. Dorfman will acidize the well with 1000 gallons of HCL. |
1100176770 | 2010-03-30 | Salt Water Injection Well | No Violations | The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the brine tank battery. |
1114313993 | 2011-05-20 | Salt Water Injection Well | No Violations | The injection system was running at the time of the inspection. The injection line was over pressured at 1200 PSI. I notified Dave Eberling (330-257-6106) of Dorfman. He immediately shut the system down. The top joint of the injection tubing is spalling off and needs to be replaced. I also informed Greg New. There were no violations at the brine tank battery. |
1162025241 | 2009-04-02 | Salt Water Injection Well | No Violations | The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the brine tank battery. |
1234325897 | 2002-10-16 | Salt Water Injection Well | No Violations | Routine inspection revealed no violations at this time . The injection pump is apart for repairs at this time . They are also in the process of removing the storage tank from inside the dike at the wellhead . They are going to replace the liner inside the dike . Didnt check the injection pressure since the pump was apart and the wellhead partially disassembled . |
124990549 | 2017-3-27 0:00: | SW | No Violations | |
1283615768 | 2017-11-02 | Salt Water Injection Well | No Violations | I found a storage tank and pump with a pre-fab building in good repair on the day of my inspection. The injection will is in front of the building. The well was operating on this day. An identification sign is posted on a wooden board located inside of the facility. I observed no spills or leaks. I called Brineaway and instructed the identification sign to be posted outside in a conspicuous location with a follow-up inspection by 11/9/2017 |
1288i268 | 2002-1-23 0:00: | SW | No Violations | 1.00 |
1288i328 | 2002-3-5 0:00:0 | SW | No Violations | 1.00 |
1298921626 | 2004-09-21 | Salt Water Injection Well | No Violations | NO VIOLATIONS. The system was not running at the time of the inspection. I was unable to check injection pressure. Talked to Greg New. Dorfman will plumb in a new valve. |
1319363014 | 2010-06-14 | Salt Water Injection Well | No Violations | The injection system was running at the time of the inspection. There were no violations at the wellhead or at the brine tank battery. I called Paul Shaw and told him to clean up the oil stained gravel within the lined tank battery dike at the wellhead. It was evident that the transfer stock tank had been recently overfilled. |
1321976325 | 2011-11-16 | Salt Water Injection Well | No Violations | Paul Shaw called me this morning for a Mechanical Integrity Test (MIT). When I arrived at the site, the rebuilt R-4 packer had been set at 5016.50 with 9,000 pounds compression. 60 barrels of annular inhibitor was circulated in the annulus. The annulus was pressured up to 1320 PSI. The test was started at 1320 PSI and ended at 1320 PSI after 25 minutes. The MIT PASSED. |
1424291865 | 2013-09-27 | Salt Water Injection Well | No Violations | My inspection of the well and injection facility found no violations. |
1444068890 | 2015-04-01 | Salt Water Injection Well | No Violations | A service rig released the packer and was pulling the tubing. Conditions onsite were acceptable. |
1480850139 | 2004-06-22 | Salt Water Injection Well | No Violations | Well is not in use and is scheduled for repairs. |
1497546991 | 2017-08-24 | Salt Water Injection Well | No Violations | I performed a UIC inspection on the above location. ID signs were posted. No noted violations were noted at this time. The unload pad for this injection well is the same as the Foltz Brianeway 1351 and the Kolm 1295 |
1529680222 | 2018-06-22 | Salt Water Injection Well | No Violations | I found the injection well not in operation. An identification sign is posted at the well and tank battery. I observed no leaks or spills. There are no violations at this time. |
1539691489 | 2018-10-15 | Salt Water Injection Well | No Violations | I was on location to witness a mechanical integrity test. Bishop Well Services was the contracted rig on location. Bishop set a new Haliburton R-
0 minutes: 1,200 psi 5 minutes: 1,200 psi 15 minutes: 1,200 psi Pressure on the annulus held static for the entire 15 minutes. MIT passed. |
1547241550 | 2008-06-12 | Salt Water Injection Well | No Violations | The injection system was running at the time of the inspection. There were no violations at the wellhead or at the brine tank battery. |
1559827156 | 2016-03-09 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
1561367699 | 2005-06-28 | Salt Water Injection Well | No Violations | NO VIOLATIONS. The disposal facility was running at the time of the inspection. |
1561563499 | 2019-6-26 0:00: | SW | No Violations | 1.00 |
1579014973 | 2020-1-14 0:00: | SW | No Violations | 1.10 |
1598410388 | 2009-05-28 | Salt Water Injection Well | No Violations | The injection system was running at the time of the inspection. There were no violations at the wellhead or at the brine tank battery. |
1620889278 | 2011-10-25 | Salt Water Injection Well | No Violations | The injection system was not running at the time of the inspection. The system is down for repairs. No pressure readings were taken. I discussed the repairs with Greg New and Paul Shaw. The top joint of injection tubing will be replaced and the lined stock tank/injection pump dike will be pumped out and cleaned. A service rig will be coming in next week. |
1680717923 | 2019-2-5 0:00:0 | SW | No Violations | 0.40 |
1699464840 | 2006-05-24 | Salt Water Injection Well | No Violations | The system was running at the time of the inspection. There were no violations at the wellhead or at the tank battery. |
1699967759 | 2009-09-02 | Salt Water Injection Well | No Violations | The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the brine tank battery. |
1716866321 | 2010-09-07 | Salt Water Injection Well | No Violations | The injection system was running at the time of the inspection. There were no violations at the wellhead or at the brine tank battery. |
1744713566 | 2015-09-23 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. The pump was off, at the time. The chart recorded a larger pressure difference with the pump operating. There were no violations found. |
1747174095 | 2008-09-25 | Salt Water Injection Well | No Violations | The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the brine tank battery. |
1757562614 | 2016-03-08 | Salt Water Injection Well | No Violations | The injection well and surface facility were inspected. There were no violations found at the time. |
2051359983 | 2012-07-25 | Salt Water Injection Well | No Violations | My inspection of the well site and injection facility found no violations. The pump was operating at the time. |
2052225348 | 2014-09-25 | Salt Water Injection Well | Violations Noted | The 1/4 inch valve, on the tubing, was stuck shut. The injection pressure reading was taken from the pressure shut-off switch. |
2068766466 | 2008-12-17 | Salt Water Injection Well | No Violations | The injection system was not running at the time of the inspection. There were no violations at the wellhead or at the brine tank battery. |
262740422 | 2019-12-5 0:00: | SW | No Violations | 1.30 |
297755979 | 2007-12-19 0:00 | SW | No Violations | |
33981074 | 2020-7-21 0:00: | SW | No Violations | 0.60 |
367881384 | 2005-2-4 0:00:0 | SW | No Violations | |
415431848 | 2007-6-27 0:00: | SW | No Violations | |
41781728 | 2004-9-24 0:00: | SW | No Violations | |
509665470 | 2017-5-9 0:00:0 | SW | No Violations | |
611832726 | 2015-3-31 0:00: | SW | No Violations | |
624105809 | 2010-12-17 0:00 | SW | No Violations | |
652468891 | 2018-3-26 0:00: | SW | No Violations | 3.50 |
71225919 | 2018-8-29 0:00: | SW | No Violations | 0.40 |
76306352 | 2003-5-22 0:00: | SW | No Violations | |
765486711 | 2008-3-20 0:00: | SW | No Violations | |
77752597 | 2020-6-4 0:00:0 | SW | No Violations | 0.80 |
796436419 | 2013-6-25 0:00: | SW | No Violations | |
823914431 | 2019-4-11 0:00: | SW | No Violations | 0.40 |
879113065 | 2013-12-27 0:00 | SW | No Violations | |
881867059 | 2018-7-19 0:00: | SW | No Violations | 1.00 |
892500069 | 2015-5-29 0:00: | SW | No Violations | |
922563185 | 2018-3-7 0:00:0 | SW | No Violations | 1.50 |
952903738 | 2005-11-14 0:00 | SW | No Violations | |
UIC1659 | 1997-5-5 0:00:0 | SW | No Violations | |
UIC1660 | 1997-5-5 0:00:0 | SW | No Violations | |
UIC1749 | 1999-1-29 0:00: | SW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0124990549 | US-OH-106688 | 2017-11-21 | 9-3-07(D) | Exceeding maximum allowable injection pressure |
2052225348 | US-OH-120901 | 2018-01-13 | 9-3-05(B)4 | Violation of injection tubing/fitting requirements |
For data sources see[9]