34-133-24290

Well Details

Well ID: 34-133-24290
Loading map...
Country: United States
State: Ohio
County: <County>
Municipality:
Operator Name: BECK ENERGY CORPORATION
Well Pad ID:
Farm/Lease Name: GME
License Status: Producing
License Date: 2005-03-28
Spud Date: 2006-01-25
Spud Drilling Contractor: WILDCAT DRILLING
Final Drill Date: 2006-01-29
Well Total Depth: 4462.00 ft
Configuration: Vertical
Latitude: 41.170000
Longitude: -81.230000

For data sources see[1]

Well History

Well Status Well Status Date Comment
APP 2005-03-28 Proposed Formations:CLINTON, Issued Date:3/28/2005, Expired Date:3/28/2006 6:00:00 AM, Drilling unit acres:40, Proposed Well Type:OG, Proposed Well Class:POOL
Original Spud 2006-01-25 RBDMS Rec
Completed 2006-01-29 RBDMS Rec
Reached Total Depth 2006-01-29 RBDMS Rec
Construction Permit Expires 2006-03-28 RBDMS Rec
Completion Report Received 2006-09-22 RBDMS Rec
Record Last Modified 2017-02-15 RBDMS Rec

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-12-15 4234 4267 35
4234 4267 35
4234 4267 35

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 90000 Gal 0

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
2006 BECK ENERGY CORPORATION 575.00 0.00 0
2007 BECK ENERGY CORPORATION 6259.00 0.00 365
2008 BECK ENERGY CORPORATION 2309.00 0.00 365
2009 BECK ENERGY CORPORATION 2647.00 0.00 365
2010 BECK ENERGY CORPORATION 3593.00 0.00 365
2011 BECK ENERGY CORPORATION 2862.00 0.00 365
2012 BECK ENERGY CORPORATION 2298.00 0.00 366
2013 BECK ENERGY CORPORATION 2179.00 0.00 365
2014 BECK ENERGY CORPORATION 2841.00 0.00 365
2015 BECK ENERGY CORPORATION 19284.00 142.00 365
2016 BECK ENERGY CORPORATION 15298.00 0.00 365
2017 BECK ENERGY CORPORATION 13097.00 0.00 365
2018 BECK ENERGY CORPORATION 12098.00 108.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
2006 BECK ENERGY CORPORATION Brine 2296
2007 BECK ENERGY CORPORATION Brine 148 365
2008 BECK ENERGY CORPORATION Brine 140 365
2009 BECK ENERGY CORPORATION Brine 0 365
2010 BECK ENERGY CORPORATION Brine 0 365
2011 BECK ENERGY CORPORATION Brine 0 365
2012 BECK ENERGY CORPORATION Brine 0 366
2013 BECK ENERGY CORPORATION Brine 0 365
2014 BECK ENERGY CORPORATION Brine 0 365
2015 BECK ENERGY CORPORATION Brine 210 365
2016 BECK ENERGY CORPORATION Brine 50 365
2017 BECK ENERGY CORPORATION Brine 150 365
2018 BECK ENERGY CORPORATION Brine 70 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1161294232 2007-1-4 0:00:0 PW No Violations
-1239055128 2007-5-9 0:00:0 PL No Violations
-1327044687 2018-12-28 0:00 UP No Violations 0.50
-169748210 2007-4-11 0:00: PL No Violations
-1828668612 2007-2-27 0:00: PW No Violations
-1915981000 2008-11-28 0:00 PW No Violations
-1954179163 2006-12-20 0:00 PW No Violations
-1981398106 2006-1-30 0:00: DD No Violations
-216843685 2006-12-20 0:00 PL No Violations
-259080560 2007-3-21 0:00: PW No Violations
0105156007 2006-02-28 Drill / Deepen / Reopen No Violations Status check inspection. The drilling pits have been solidified and closed. The well has not been fraced and the site has been partially graded. No violations at this time.
0169748210 2007-04-11 Preliminary Restoration No Violations The site still needs finish grade, seeding and mulching in order to correct the oustanding violation.
0216843685 2006-12-20 Preliminary Restoration Violations Noted Preliminary restoration was due by November 1, 2006. The site still needs to be graded, seeded and mulched.
0247237269 2006-02-01 Drill / Deepen / Reopen No Violations The drilling rig has moved off. The pits are fenced off and have sufficient freeboard for rainfall, snowfall or surface runoff.
0259080560 2007-03-21 Production Wells No Violations The required safety equipment has been installed and that violation is corrected. The failure to restore within nine months violation is still open.
0270969587 2006-01-25 Drill / Deepen / Reopen No Violations Wildcat Drilling is moving on site and should spud the well later today. The pits are lined and in good condition.
0497191211 2007-03-19 Production Wells No Violations The safety equipment has not been installed as required. Failure to do so will result in immediate placement on the permit hold list.
1035480673 2006-01-23 Drill / Deepen / Reopen No Violations The lease road has been built. Wildcat Drilling should be moving on site in two days. The drilling permit was issued before the new rules. I still contacted Beck Energy and ordered the required signage and fencing.
105156007 2006-2-28 0:00: DD No Violations
1161294232 2007-01-04 Production Wells No Violations The required fencing has been installed. The company still needs to install the charcoal filter, pressure relief valve and lightning arrestor to the tank battery to be in compliance.
1223529293 2007-04-24 Production Wells No Violations The site has been graded but still needs to be seeded and mulched in order to correct the violation.
1239055128 2007-05-09 Preliminary Restoration No Violations The site has finally been graded, seeded and mulched. Preliminary restoration is approved and the violation is corrected.
1327044687 2018-12-28 UrbanProduction Wells No Violations Status check inspection of this Clinton Sandstone well. My inspection found the wellhead fenced and locked. The wellhead is equipped with 1.5 tubing and rods and operating with the aid of a natural gas powered pumping unit. This well produces to a diked, fenced, and locked tank battery on location. The battery contains one (1) 210 barrel tank, two (2) 35 barrel poly tanks, and a horizontal separator with an associated meter run. A gauge on the sales line indicates a pressure of 60psi and the chart indicates a differential production pressure of 50psi. The load lines are locked and the tank and vent stack are equipped with the required equipment. The required ID is posted at the tank battery. No violations.
1363703851 2007-01-29 Production Wells No Violations The required safety equipment has been delivered but has not been installed. The violation will be resolved as soon as the equipment is installed.
1828668612 2007-02-27 Production Wells No Violations The safety equipment has been delivered to the site but still needs to be installed. I called and spoke with David Beck and told him that the equipment must be installed immediately. If not installed by March 9, I will request that Beck Energy be placed on permit hold.
1915981000 2008-11-28 Production Wells No Violations The well is shut in at this time. The GME plant is closed which may explain why the well is shut in. I will check again later this winter before calling Beck for an explanation.
1954179163 2006-12-20 Production Wells Violations Noted Status check inspection found that this well is in production but does not have the required fencing, charcoal filter, lightning arrestor and pressure relief valve. The well is to be shut in immediately and remain shut in until all are in compliance.
1981398106 2006-01-30 Drill / Deepen / Reopen No Violations Wildcat Drilling is moving off site. The pits are lined and partially fenced. I told Beck to finish fencing off the pits after the rig moves off. No violations at this time.
247237269 2006-2-1 0:00:0 DD No Violations
270969587 2006-1-25 0:00: DD No Violations
497191211 2007-3-19 0:00: PW No Violations

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0216843685 US-OH-122145 2006-12-21 Failure to restore land surface within 9 mos. (CHANGE) (REPLACE)
1954179163 US-OH-119711 2006-12-21 General Safety

For data sources see[9]