34-133-20429

Well Details

Well ID: 34-133-20429
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Ravenna Township
Operator Name: ENERVEST OPERATING LLC
Well Pad ID:
Farm/Lease Name: BOGUS WALTER
License Status: Plugged and Abandoned
License Date: 2018-12-07
Spud Date: 1966-03-04
Spud Drilling Contractor:
Final Drill Date: 1966-03-13
Well Total Depth: 4303.00 ft
Configuration: Vertical
Latitude: 41.140000
Longitude: -81.270000

For data sources see[1]

Well History

Well Status Well Status Date Comment
CO 1801-01-02 240 EAST OHIO GAS CO
Oil and Gas 1802-01-01
Original Spud 1966-03-04 GL=1070.9
Completed 1966-03-13 GL=1070.9
Reached Total Depth 1966-03-13 GL=1070.9
CO 1995-04-20 182 BELDEN & BLAKE CO GeoDate
Change of Owner 2007-04-27 Operator changed from 182, BELDEN & BLAKE CORPORATION to 7578, ENERVEST OPERATING LLC
APP 2018-12-07 Proposed Formations:CLINTON SAND, Issued Date:12/7/2018, Expired Date:12/6/2020 12:00:00 PM, Drilling unit acres:10, Proposed Well Type:OG, Proposed Well Class:
Record Last Modified 2018-12-14 GL=1070.9
Construction Permit Expires 2020-12-06 GL=1070.9

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4204 4211 14
2006-09-11 4218 4225 14
4204 4211 14
4204 4211 14
2006-09-11 4230 4234 8

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
GEL 0 16674 Gal 23000 442# J-101, 15 GALS ADMALL, 75 7/8 PERF BALLS
ACID 0 50 Gal 0 MUD ACID

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 DOMINION EAST OHIO 10.00 55.00 0
1995 BELDEN & BLAKE CORPORATION 2868.00 0.00 151
1996 BELDEN & BLAKE CORPORATION 1983.00 0.00 268
1997 BELDEN & BLAKE CORPORATION 2143.00 33.00 295
1998 BELDEN & BLAKE CORPORATION 2189.00 0.00 365
1999 BELDEN & BLAKE CORPORATION 2845.00 82.00 363
2000 BELDEN & BLAKE CORPORATION 2920.00 0.00 362
2001 BELDEN & BLAKE CORPORATION 5248.00 48.00 341
2002 BELDEN & BLAKE CORPORATION 4400.00 0.00 365
2003 BELDEN & BLAKE CORPORATION 5653.00 50.00 365
2004 BELDEN & BLAKE CORPORATION 6140.00 33.00 366
2005 BELDEN & BLAKE CORPORATION 6118.00 17.00 365
2006 BELDEN & BLAKE CORPORATION 6472.00 0.00 365
2007 ENERVEST OPERATING LLC 5849.00 29.00 365
2008 ENERVEST OPERATING LLC 5034.00 27.00 365
2009 ENERVEST OPERATING LLC 5336.00 0.00 365
2010 ENERVEST OPERATING LLC 3457.00 46.00 365
2011 ENERVEST OPERATING LLC 2077.00 0.00 0
2012 ENERVEST OPERATING LLC 6585.00 36.00 366
2013 ENERVEST OPERATING LLC 7368.00 44.00 365
2014 ENERVEST OPERATING LLC 5045.00 0.00 365
2015 ENERVEST OPERATING LLC 6299.00 43.00 365
2016 ENERVEST OPERATING LLC 6037.00 0.00 366
2017 ENERVEST OPERATING LLC 4726.00 42.00 365
2018 ENERVEST OPERATING LLC 2960.00 20.00 282

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 DOMINION EAST OHIO Brine 0 0
1995 BELDEN & BLAKE CORPORATION Brine 0 151
1996 BELDEN & BLAKE CORPORATION Brine 0 268
1997 BELDEN & BLAKE CORPORATION Brine 29 295
1998 BELDEN & BLAKE CORPORATION Brine 0 365
1999 BELDEN & BLAKE CORPORATION Brine 45 363
2000 BELDEN & BLAKE CORPORATION Brine 0 362
2001 BELDEN & BLAKE CORPORATION Brine 68 341
2002 BELDEN & BLAKE CORPORATION Brine 15 365
2003 BELDEN & BLAKE CORPORATION Brine 45 365
2004 BELDEN & BLAKE CORPORATION Brine 102 366
2005 BELDEN & BLAKE CORPORATION Brine 71 365
2006 BELDEN & BLAKE CORPORATION Brine 25 365
2007 ENERVEST OPERATING LLC Brine 42 365
2008 ENERVEST OPERATING LLC Brine 35 365
2009 ENERVEST OPERATING LLC Brine 24 365
2010 ENERVEST OPERATING LLC Brine 6 365
2011 ENERVEST OPERATING LLC Brine 58
2012 ENERVEST OPERATING LLC Brine 89 366
2013 ENERVEST OPERATING LLC Brine 88 365
2014 ENERVEST OPERATING LLC Brine 0 365
2015 ENERVEST OPERATING LLC Brine 29 365
2016 ENERVEST OPERATING LLC Brine 0 366
2017 ENERVEST OPERATING LLC Brine 37 365
2018 ENERVEST OPERATING LLC Brine 4 282

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-268010291 2018-12-28 0:00 UP No Violations 0.50
0002403996 2018-09-20 UrbanProduction Wells No Violations I inspected this well at the request of the Orphan Well program to check the pressure on the annulus between the 7 surface casing and the 4.5 production casing. I spoke with Field Supervisor Kyle Ahbel this morning and he is going to inform Joe Teppert of my request to expose and gauge the annular pressure. Joe called me back and told me that Josh Schrock had dug up the annulus and found that the annulus and casing pressure were equalized at a pressure of 490psi. He told me the well has been, and is currently, shut-in to replace the 100 barrel tank which has been completed. The equalized pressure indicates that the 4.5 production casing has lost integrity and is charging up the annulus with pressure. The well is currently equipped with 1.5 tubing and a plunger lift system. This well produces through a vertical separator to the east of the wellhead and to a diked tank battery to the west containing a refurbished, 100 barrel tank. It is determined at this time that the surface casing seat is over pressurized and exceeds the maximum allowable pressure of 180psi (.303 x 594). I called Joe Teppert and asked him to begin selling the pressure off of the well. The pressures will be monitored at the wellhead until the issue is corrected.
0268010291 2018-12-28 UrbanProduction Wells No Violations Follow-up to Compliance Notice #1650442205 issued for defective casing that resulted in over pressurization of 7 X 4.5 annulus that was found to be 490psi on 9/20/18. I inspected the location today and found that the annular pressure gauge is reading just over 160psi and is below the maximum allowable pressure of 180psi. The 1.5 gate valve below the plunger lubricator is closed and the valve on the 4.5 production casing port is open and keeping the pressure off of the 7 surface casing annulus. There is currently 12psi on the domestic supply line. The chart at the meter shack (MOA) shows line pressure fluctuating between 170psi and 150psi. I spoke with Enervest Southern District Superintendent Tim McConaha and he asked for an extension to plug the well by May 1, 2019. Tim told me that the well is currently supplying domestic gas to a rental property and they have no other source of gas for heat at this time. He said he is currently working with Dominion to get gas service for the property. A plugging permit was issued to Enervest on 12/7/2018 to plug and abandon this well. I have approved the extension until May 1, 2019 contingent that Enervest continue to monitor the annular pressure, and that it is not allowed to exceed the maximum allowable pressure of 180psi. This violation will continue until the well is properly plugged and abandoned.
0747327097 2018-11-16 UrbanProduction Wells No Violations Follow-up to Compliance Notice #1650442205 issued for defective casing that resulted in over pressurization of 7 X 4.5 annulus. My inspection to found the annular pressure gauge is reading just under 160psi and is below the maximum allowable pressure of 180psi. The 1.5 gate valve below the plunger lubricator is closed and the valve on the 4.5 production casing port is open and keeping the pressure off of the 7 surface casing annulus. There is currently 7psi on the domestic supply line. I spoke with Enervest Operations Superintendent Doug Beaghle on 10/22/18, and he proposed resetting the tubing on a packer, just above the perforations. I told him that this would be acceptable contingent on the annular pressure being remediated. I spoke with Operations Superintendent Tim McConaha on 11/6/18, and he told me that Enervest has decided that it would be more economically feasible to plug and abandon the well. He requested an extension to plug the well in the spring of 2019 when the weather conditions improve. I told him I would discuss the extension with DOGRM Northeast Regional Supervisor Tom Hill and let him know if the extension is approved. I will continue to monitor the annular pressure at this well for compliance.
1543415523 2018-11-26 UrbanProduction Wells No Violations Follow-up to Compliance Notice #1650442205 issued for defective casing that resulted in over pressurization of 7 X 4.5 annulus that was found to be 490psi on 9/20/18. I inspected the location today with DOGRM Northeast Regional Supervisor Tom Hill. The inspection of the wellhead today found that the annular pressure gauge is reading just under 160psi and is below the maximum allowable pressure of 180psi. The 1.5 gate valve below the plunger lubricator is closed and the valve on the 4.5 production casing port is open and keeping the pressure off of the 7 surface casing annulus. There is currently 12psi on the domestic supply line. Enervest Operating plans to plug the well this spring. This violation will continue until the well is properly plugged and abandoned.
1550071437 2019-02-13 UrbanProduction Wells No Violations Follow-up to Compliance Notice #1650442205 for defective casing. I inspected this well to check the annular pressure between the 7 surface casing and 4-1/2 production casing. The gate valve on the 1.5 tubing and plunger lift assembly is currently closed. The casing port valve is currently open to keep pressure off of the annulus and the annular gauge reads170psi and is below the maximum allowable pressure of 180psi. The domestic tap is continuing to supply house gas at a pressure of 7psi. The current line pressure at the meter shack (MOA) is between 160psi & 170psi. This well is scheduled to be plugged in the spring of 2019 and the violation will remain open until that time.
1560435288 2019-6-13 0:00: PB No Violations 1.10
1562677685 2019-7-9 0:00:0 FR No Violations 0.80
1570029886 2019-10-2 0:00: FR No Violations 1.10
1589818652 2019-03-27 UrbanProduction Wells No Violations Follow-up to Compliance Notice #1650442205 issued for defective casing that resulted in over pressurization of 7 X 4.5 annulus that was found to be 490psi on 9/20/18. I inspected the location today and found that the annular pressure gauge is reading just over 155psi and is below the maximum allowable pressure of 180psi. The 1.5 gate valve below the plunger lubricator is closed and the valve on the 4.5 production casing port is open and keeping the pressure off of the 7 surface casing annulus. This violation will continue until the well is plugged and abandoned.
1650442205 2018-10-01 UrbanProduction Wells Violations Noted Status check inspection of this Clinton Sandstone well that was found to be over-pressurized on the 4.5 X 7 surface casing annulus and equalized with the 4.5 production casing at 490psi on 9/20/18. Enervest personnel have been selling the pressure down and the annular gauge currently indicates a pressure of 160psi and is below the maximum allowable pressure of 180psi (calculated by multiplying the depth of the casing seat (594) by .303). The chart in the meter shack (MOA) indicates that the well has cycled one (1) time over the prior 7 days and is currently at the line pressure of 160psi. Based on the equalization of pressures found between the casing and annulus in this well, it is determined that the 4.5 production casing is defective. Enervest Operating, LLC will be afforded thirty (30) days from the issuance of this Notice to perform one of the following activities; 1) repair the defective casing, or 2) plug and abandon the well. Failure to comply with this Notice may result in further enforcement action.
2403996 2018-9-20 0:00: UP No Violations 1.80
747327097 2018-11-16 0:00 UP No Violations 1.20

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
1650442205 US-OH-116276 2019-01-15 NONE17 Defective casing, leaking well