Well Details

Well ID: 34-133-20406
Loading map...
Country: United States
State: Ohio
County: Portage
Municipality: Rootstown Township
Operator Name: STEPHEN J SVETLAK LLC
Well Pad ID:
Farm/Lease Name: THOMPSON B & H COMM
License Status: Producing
License Date: 1995-05-16
Spud Date: 1965-09-17
Spud Drilling Contractor:
Final Drill Date: 1965-09-26
Well Total Depth: 4390.00 ft
Configuration: Vertical
Latitude: 41.090000
Longitude: -81.270000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1965-09-17 GL=1083.1
Completed 1965-09-26 GL=1083.1
Reached Total Depth 1965-09-26 GL=1083.1
CO 1995-04-20 182 BELDEN & BLAKE CO
Construction Permit Expires 1996-05-15 GL=1083.1
Change of Owner 2001-04-05 Operator changed from 457, ALSID OIL & GAS to 6970, VANGUARD OIL & GAS LLC
Change of Owner 2002-09-25 Operator changed from 6970, VANGUARD OIL & GAS LLC to 6791, NORMAN D INVESTMENTS
Change of Owner 2005-03-14 Operator changed from 6791, NORMAN D INVESTMENTS to 7773, SVETLAK STEPHEN J LLC
Record Last Modified 2013-10-03 GL=1083.1

For data sources see[2]

Perforation Treatments

Perforation Date Interval Top (ft) Interval Base (ft) Number of Shots
2006-09-11 4284 4298 28
2006-09-11 4309 4314 1
4284 4298 28
4284 4298 28
2006-09-11 4325 4329 8

For data sources see[3]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 677 Bbl 26000 R.P. 24 HRS.

For data sources see[4]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1984 DOMINION EAST OHIO 1085.00 0.00 0
1985 DOMINION EAST OHIO 989.00 126.00 365
1986 DOMINION EAST OHIO 626.00 58.00 365
1987 DOMINION EAST OHIO 347.00 50.00 128
1988 DOMINION EAST OHIO 835.00 66.00 265
1989 DOMINION EAST OHIO 1654.00 0.00 356
1990 DOMINION EAST OHIO 1315.00 0.00 365
1991 DOMINION EAST OHIO 1160.00 0.00 365
1992 DOMINION EAST OHIO 1346.00 0.00 365
1993 DOMINION EAST OHIO 1678.00 56.00 365
1994 DOMINION EAST OHIO 1678.00 56.00 365
1995 BELDEN & BLAKE CORPORATION 870.00 0.00 151
1996 BELDEN & BLAKE CORPORATION 691.00 0.00 366
1997 BELDEN & BLAKE CORPORATION 240.00 0.00 85
1999 ALSID OIL & GAS 1336.00 46.00 365
2000 VANGUARD OIL & GAS LLC 1293.00 0.00 365
2001 VANGUARD OIL & GAS LLC 1196.00 53.00 365
2002 CONSORTIUM ENERGY LLC 1541.00 0.00 365
2003 CONSORTIUM ENERGY LLC 1541.00 0.00 365
2005 VANGUARD OIL & GAS LLC 0.00 0.00 0
2006 VANGUARD OIL & GAS LLC 0.00 0.00 0
2007 VANGUARD OIL & GAS LLC 0.00 0.00 0
2008 STEPHEN J SVETLAK LLC 1373.00 0.00 365
2009 STEPHEN J SVETLAK LLC 1287.00 0.00 365
2014 STEPHEN J SVETLAK LLC 1424.00 0.00 365
2015 STEPHEN J SVETLAK LLC 1364.00 0.00 365
2016 STEPHEN J SVETLAK LLC 1209.00 0.00 365

For data sources see[5] [6]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1984 DOMINION EAST OHIO Brine 0 0
1985 DOMINION EAST OHIO Brine 13 365
1986 DOMINION EAST OHIO Brine 48 365
1987 DOMINION EAST OHIO Brine 23 128
1988 DOMINION EAST OHIO Brine 60 265
1989 DOMINION EAST OHIO Brine 0 356
1990 DOMINION EAST OHIO Brine 0 365
1991 DOMINION EAST OHIO Brine 0 365
1992 DOMINION EAST OHIO Brine 0 365
1993 DOMINION EAST OHIO Brine 0 365
1994 DOMINION EAST OHIO Brine 0 365
1995 BELDEN & BLAKE CORPORATION Brine 0 151
1996 BELDEN & BLAKE CORPORATION Brine 0 366
1997 BELDEN & BLAKE CORPORATION Brine 0 85
1999 ALSID OIL & GAS Brine 11 365
2000 VANGUARD OIL & GAS LLC Brine 129 365
2001 VANGUARD OIL & GAS LLC Brine 40 365
2002 CONSORTIUM ENERGY LLC Brine 75 365
2003 CONSORTIUM ENERGY LLC Brine 75 365
2005 VANGUARD OIL & GAS LLC Brine 0 0
2006 VANGUARD OIL & GAS LLC Brine 0 0
2007 VANGUARD OIL & GAS LLC Brine 0 0
2008 STEPHEN J SVETLAK LLC Brine 365
2009 STEPHEN J SVETLAK LLC Brine 365
2014 STEPHEN J SVETLAK LLC Brine 0 365
2015 STEPHEN J SVETLAK LLC Brine 0 365
2016 STEPHEN J SVETLAK LLC Brine 0 365

For data sources see[7] [8]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1240015371 2017-12-22 0:00 UP No Violations 0.60
-1933895633 2018-1-8 0:00:0 UP No Violations 0.20
-281730660 2018-10-22 0:00 UP No Violations 1.00
0281730660 2018-10-22 UrbanProduction Wells No Violations Follow-up to Chiefs Order 2017-441 for failure to maintain liability insurance and to determine if Stephen J. Svetlak, LLC is in compliance with the order to suspend all oil and gas operations in the State of Ohio. My inspection today found a flanged wellhead equipped with gate valves, three (3) inch flow line, and operating as an open flow, swab well. The production gate valve is open and the well is producing through a vertical separator to the west. A gauge indicates a pressure of 110psi on the separator. A one (1) inch line plumbed to the three (3) inch separator sales line is supplying domestic gas through regulators and a meter to the south. The tank battery consists of one (1) 100 barrel tank and is diked. Gas production is being recorded at a meter shack (MOA) east of the wellhead and the sales line valve is open. There is an odor of natural gas inside the meter shack and the 16 day chart was changed 11 days ago and is actively recording production at a differential pressure of 110psi. It is determined that the well is in production in violation of Chiefs Order #2017-441. Photos are available upon request.
1240015371 2017-12-22 UrbanProduction Wells No Violations Follow-up to Chiefs Order 2017-441 for failure to maintain liability insurance and to determine if Stephen J. Svetlak, LLC is in compliance with the order to suspend all oil and gas operations in the State of Ohio. My inspection today found the master valve on the wellhead and the gate valve on the flow line open. The valve on the one (1) inch line on the back of the wellhead is closed. A gauge on the vertical separator currently reads 100psi. There is a domestic tap just south of the separator that is supplying house gas. The valves at the meter run (MOA) are open and the chart indicates that well is currently in production in violation of Chiefs Order 2017-441. The required ID is not posted at the wellhead or at the tank battery.
1312473708 2017-05-17 Production Wells No Violations I inspected this well to follow up on Chiefs Order #2013-136 issued on 9/25/2013. The operator, Stephen J. Svetlak, LLC, has failed to maintain proof of liability insurance as required by ORC 1509.07(A) and has been found in material and substantial violation for failing to maintain coverage. My inspection found that the well was still in production and is in direct violation of the Chiefs Order to immediately suspend all oil and gas operations in the State of Ohio and 1509.07[C] of the Ohio Revised Code. I documented that the well is producing into a Dominion/East Ohio Gas line. The operator has not reported production since 2009. The ID sign on the tank does not meet urban production. The well is a swab well and produces through a vertical separator and into a 100 barrel tank the meter site is off the production unit (41.09752 / -81.27776. There is 120psi at the separator and a domestic hook up with 10psi.
1384956143 2013-10-15 UrbanProduction Wells No Violations I inspected this well to follow up on Chiefs Order #2013-136 issued on 9/25/2013. The operator, Stephen J. Svetlak, LLC, has failed to maintain proof of liability insurance as required by ORC 1509.07(A) and has been found in material and substantial violation for failing to maintain coverage. My inspection found that the well was still in production and is in direct violation of the Chiefs Order to immediately suspend all oil and gas operations in the State of Ohio and 1509.07[C] of the Ohio Revised Code. I documented that the well is producing into a Dominion/East Ohio Gas line and took pictures inside the meter run showing production and that the chart was changed out by Tri State Measurement on 10/01/13. The operator has not reported production since 2009. The ID sign on the tank does not meet urban production well requirements and indicates Alsid Oil & Gas as the owner of the well. The well is a swab well and produces through a vertical separator and into a 100 barrel tank. There is 120psi at the separator and a domestic hook up with 10psi.
1514487967 2017-12-27 UrbanProduction Wells No Violations Follow-up to Chiefs Order 2017-441 to determine if Stephen J Svetlak, LLC has suspended all oil and gas operations in the State of Ohio as required by the Order. I was on location with Northeast Regional Supervisor Tom Hill and Mahoning County Inspector John Fleming to conduct the follow-up inspections. The inspection today revealed that the inlet and outlet valves at the meter run (sales point) remain open. The chart has continued to record gas production from the wellhead since my initial follow-up inspection on 12/22/2017 (see photos). The well remains in production and is not in compliance with Chiefs Order 2017-441.
1514985007 2018-01-02 UrbanProduction Wells No Violations Follow-up to Chiefs Order 2017-441 to determine if Stephen J Svetlak, LLC has suspended all oil and gas operations in the State of Ohio as required by the Order. I was on location with Northeast Regional Supervisor Tom Hill to conduct the follow-up inspections. The inspection today found that the valve on the sales line has been closed and the chart indicates that the well is not currently in production. This well is in compliance with Chiefs Order 2017-441.
1933895633 2018-01-08 UrbanProduction Wells No Violations Follow-up to Chiefs Order 2017-441 to determine if Stephen J Svetlak, LLC has suspended all oil and gas operations in the State of Ohio as required by the Order. My inspection today found that the valve on the sales line is closed and the chart indicates that the well is not currently in production and only indicates a line pressure of 100psi. This well is in compliance with Chiefs Order 2017-441. No violations.
2083239579 2018-02-12 UrbanProduction Wells No Violations Follow-up to Chiefs Order #2017-441. My inspection found the valve on the two (2) inch sales line closed before the sales point tie-in. The well is shut-in as required by the Chiefs Order until the required liability insurance is obtained and submitted.

For data sources see[9]

References