If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-121-22057 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.8,"lon":-81.49,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Noble | |
Municipality: Center Township | |
Operator Name: NORTHWOOD ENERGY CORP | |
Well Pad ID: | |
Farm/Lease Name: WATSON WAYNE | |
License Status: Producing | |
License Date: 1981-03-03 | |
Spud Date: 1978-04-26 | |
Spud Drilling Contractor: MID ATLANTC DRLG | |
Final Drill Date: 1978-05-03 | |
Well Total Depth: 6030.00 ft | |
Configuration: Vertical | |
Latitude: 39.800000 | |
Longitude: -81.490000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1978-04-26 | |
Completed | 1978-05-03 | |
Reached Total Depth | 1978-05-03 | |
Plugged Back | 1978-10-30 | |
Completion Report Received | 1979-01-17 | |
CO | 1981-03-03 | 1815 TRANS ATLANTIC ENER CORP GeoDate 3/3/81 |
CO | 1994-10-21 | 4381 PELICAN PRODUCING INC GeoDate 3/3/81 |
Change of Owner | 1998-09-03 | Operator changed from 4381, PELICAN PRODUCING INC to 6239, BENNETT CANDACE L |
Change of Owner | 2013-05-07 | Operator changed from 6239, BENNETT CANDACE L to 1634, NORTHWOOD ENERGY CORP |
Record Last Modified | 2013-10-03 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2001-06-08 | 4308 | 4315 | 17 |
2001-06-08 | 5843 | 5869 | 27 |
4308 | 4315 | 17 | |
5843 | 5869 | 27 | |
4308 | 4315 | 17 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 89 Bbl | 0 | 11 BBL ACID & 78 BBL H2O | ||
H2O | 0 | 42000 Gal | 126000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | NORTHWOOD ENERGY CORP | 2555.00 | 71.00 | 365 |
2014 | NORTHWOOD ENERGY CORP | 2904.00 | 40.00 | 365 |
2015 | NORTHWOOD ENERGY CORP | 1830.00 | 0.00 | 365 |
2016 | NORTHWOOD ENERGY CORP | 1146.00 | 71.00 | 365 |
2017 | NORTHWOOD ENERGY CORP | 1449.00 | 0.00 | 365 |
2018 | NORTHWOOD ENERGY CORP | 1258.00 | 72.00 | 365 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
2013 | NORTHWOOD ENERGY CORP | Brine | 733 | 365 |
2014 | NORTHWOOD ENERGY CORP | Brine | 298 | 365 |
2015 | NORTHWOOD ENERGY CORP | Brine | 357 | 365 |
2016 | NORTHWOOD ENERGY CORP | Brine | 252 | 365 |
2017 | NORTHWOOD ENERGY CORP | Brine | 289 | 365 |
2018 | NORTHWOOD ENERGY CORP | Brine | 257 | 365 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1200504793 | 2016-4-28 0:00: | PW | No Violations | 1.00 |
-1545524653 | 2015-12-21 0:00 | PW | No Violations | 1.00 |
-1580146348 | 2016-4-13 0:00: | PW | No Violations | 3.00 |
-1829343894 | 2012-4-16 0:00: | PW | No Violations | |
-1911014194 | 2016-4-11 0:00: | PW | No Violations | 3.00 |
-1980310624 | 2020-3-9 0:00:0 | PW | No Violations | 1.00 |
-2010206677 | 2014-7-23 0:00: | PW | No Violations | |
-212935918 | 2014-7-22 0:00: | PW | No Violations | 4.00 |
-246794909 | 2014-12-17 0:00 | PW | No Violations | 1.50 |
-382540634 | 2014-7-21 0:00: | PW | No Violations | |
-869730780 | 2014-10-6 0:00: | PW | No Violations | 1.50 |
0212935918 | 2014-07-22 | Production Wells | No Violations | My inspection today finds Corps Well Service is removing the contaminated soil. I tested a spring 150 down hill of the well site for chlorides. The low range Quantab indicated the chlorides are at a level of 115 ppm. Once all visibly contaminated soil was removed I tested the soil with a low range Quantab. The test indicated chlorides in the soil were 174 ppm. |
0246794909 | 2014-12-17 | Production Wells | No Violations | My inspection today finds the contaminated area has been cleaned. The leak has been repaired and the well has been turned back on. The violation has been resolved. |
0382540634 | 2014-07-21 | Production Wells | Violations Noted | At 1:00 PM I received a phone call from Mr. Joe Dimmerling the land surface owner. Mr. Dimmerling stated that there is oil and brine leaking from the well. I responded on site at 1:50 PM. Upon arrival I witnessed the pumping unit running and brine was leaking from the polish rod liner packing. The affected area was approximately 25 at the widest point and extended 75 from the wellhead. The estimated size of the release is five to ten gallons of crude oil and two to three barrels of brine I called Bill Arnholt with Northwood Energy and notified him of the leak at 1:56 PM. Mr. Arnholt stated that he would have Corps Well Service begin the clean up today. Corps Well Service brought six men and a dozer to begin the clean up. The company was instructed to remove and replace all contaminated soil and re-establish vegetation within fifteen days. |
0540569074 | 2016-11-23 | Production Wells | Violations Noted | |
0693127786 | 2014-12-10 | Production Wells | Violations Noted | At 8:38 AM I received a telephone call from Joe Dimmerling, the surface owner. Mr. Dimmerling stated that the well was leaking at the stuffing box. I arrived at the well site at 9:00 AM. Upon my arrival I witnessed approximately one to two gallons of very thick oil covering the wellhead and the ground covering an area two feet in diameter. I called Bill Arnholt, Vice President of Operations, with Northwood Energy. I informed Mr. Arnholt that the well was leaking and it required immediate action. I also informed Mr. Arnholt that the company was in violation of 1501:9-1-07(A). Suspend operation of the well until the leak is fixed and clean all oil from the well site. |
0814885216 | 2014-06-02 | Production Wells | Violations Noted | My inspection today finds the well is equipped to be produced by a pumping unit. A ten foot area around the well has been scalded by brine. A high range Quantab found the chloride levels eighteen inches from the well in excess of 6500 ppm. The tank battery is comprised of one 100 bbl tank, one 210 bbl tank, a separator and a meter set in an earthen dike. Remove all contaminated soil and replace it within fifteen days. Plug all valves that can be opened by livestock or fence the area around the well in order to prevent damage to property. |
0869730780 | 2014-10-06 | Production Wells | No Violations | On Monday September 29 I received a phone call from Mr. Dimmerling the land surface owner. Mr. Dimmerling stated that his cattle were eating the soil on the bank below the well. I tested the soil by mixing it with fresh water, and using a low range Quantab I determined the chlorides were at 148 parts per million. This result would indicate that no further soil remediation on the site is necessary. |
1013983987 | 2020-1-7 0:00:0 | PW | No Violations | 1.00 |
1091456433 | 2014-07-31 | Production Wells | No Violations | My inspection today finds the well site has been remediated. All impacted soil was removed and replaced. Vegetation is starting to grow. The pumping unit is running at the time of my inspection. |
1100747458 | 2016-11-29 | Production Wells | No Violations | The purpose of my inspection today is a compliance notice follow up. Inspection found all contamination remediated. This satisfies the compliance notice numbered 540569074. |
1120171587 | 2015-11-09 | Production Wells | Violations Noted | At 9:07 AM, I received a voice mail message from Joe Dimmerling. Mr. Dimmerling indicated that the well was again leaking oil. Upon arrival at 9:45 AM, I observed approximately one gallon of oil laying on the ground within a 24 of the wellhead. The source of the oil was a leaking polish rod liner packing. At 9:53 I spoke to Cory McCudden with Northwood Energy and notified him of the leak. I instructed him to remove all oil and any contaminated soil. He stated that he would dispatch personnel to clean and repair the well. |
1200504793 | 2016-04-28 | Production Wells | No Violations | My inspection today finds the well site and tank battery have been cleaned. The previous violation has been resolved. |
1338458760 | 2014-06-04 | Production Wells | No Violations | I met Corey McCudden, Geologist with Northwood Energy at the well entrance. My inspection found the contaminated soil was removed and stone was placed in front of the pumping unit. All debris was removed and the wellhead was fenced off from livestock. The area still needs to be seeded. |
1403528775 | 2014-06-23 | Production Wells | No Violations | My inspection today finds the well has been brought into compliance. The contaminated soil has been removed and the area seeded. Vegetation is beginning to grow. |
1513900055 | 2017-12-18 | Production Wells | No Violations | On 12/15/2017 at 3:02 PM I returned a call to land owner Joe Dimmerling. Mr. Dimmerling stated his concerns about a potential 3 foot by 3 foot area in the snow of what he believed to be brine that was released while a brine truck with Corp Energy written on the side was loading brine from the storage tank. On 12/15/17 at 3:20 PM I contacted Corp Energy Services, a contractor for Northwood Energy, and notified them of the potential release. During my inspection there was not any snow coverage and it was lightly raining. I could not locate any signs of a brine release. The well was equipped with 4.5 inch diameter production casing with a tubing head, 2.375 inch diameter tubing, rods, Trapper stuffing box leak detector, and a pumping unit powered by an electric motor. The production valves were in the open position. A line was attached to the drain port on the trapper and ran to a steel 55 gallon drum. The production equipment consists of one 100 barrel tank, one 210 barrel tank, one drip, a horizontal separator, and a meter run with a 2 inch diameter line, .375 inch orifice, and a chart recorder with a current chart. All production equipment is within an earthen dike. The identification was located on the tank and the production records were current. |
1524488929 | 2018-04-20 | Production Wells | No Violations | Joe Dimmerling called and left a voicemail at 11:40 a.m. on 4/20/18 stating that two small holes were found in one of the tanks that resembled bullet holes. During my inspection I was accompanied by land owner Joe Dimmerling. Two small puncture holes were found in the east side of the 210 barrel tank. The holes were slowly draining produced fluids. I called Mike Corp, a contractor for Northwood Energy, at 12:06 p.m. Mr. Corp directed a truck to come and remove the product from the 210 barrel tank. The tank was located within an earthen dike and there were not any fluids found on the outside of the dike. |
1524746427 | 2018-04-20 | Production Wells | No Violations | While inspecting well 3412123549 on the adjacent land Joe Dimmerling arrived on location. Mr. Dimmerling asked if I could check a spot near the lease road where he believes there was a brine release. When I arrived on location I could not find any obvious signs of a brine release in the area Mr. Dimmerling described. The area consisted of a dirt surface that was lightly graveled. |
1531145973 | 2018-07-09 | Production Wells | No Violations | On 4/20/18 inspection found 2 holes within the 210 barrel tank. During my inspection today the 210 barrel tank had been patched to prevent future leaks. The earthen dike was free of contamination. |
1545524653 | 2015-12-21 | Production Wells | No Violations | My inspection today finds the previous violation has been resolved. The affected area has been reseeded and vegetation has been established. The area is still fenced to keep out livestock. |
1580146348 | 2016-04-13 | Production Wells | No Violations | I am accompanied on my inspection today by Jake Glascock. Jake and I took samples from a cattle water trough that is fed from a spring down hill from the well site. The area affected by the previous spill has been cleaned and all oil removed. |
1588169809 | 2014-07-24 | Production Wells | No Violations | My inspection today finds the well site has been seeded and mulched. |
1588685752 | 2020-5-5 0:00:0 | PW | No Violations | |
1651502783 | 2017-07-06 | Production Wells | No Violations | The purpose of my inspection was a status check on a production well. During my inspection the well was equipped with 4.5 inch diameter production casing with a tubing head, 2.375 inch diameter tubing, rods, Trapper stuffing box leak detector, and a pumping unit powered by an electric motor. The production valves were in the open position. The production equipment consists of one 100 barrel tank, one 210 barrel tank, one drip, a horizontal separator, and a meter run with a 2 inch diameter line, .375 inch orifice, and a chart recorder with a current chart. All production equipment is within an earthen dike. The identification was located on the tank and the production records were current. |
1793255432 | 2020-3-26 0:00: | PW | No Violations | 1.00 |
1829343894 | 2012-04-16 | Production Wells | No Violations | Upon inspection of well found 4.5 production casing -2.375 tubing with all production valves closed and the electric turned off -well is set up to be produced by means of a pumping unit -inspector will note landowner well that is idle due to production tank being hit by lighting last year. |
1911014194 | 2016-04-11 | Production Wells | Violations Noted | My inspection today finds the well is again leaking. The Trapper stuffing box leak detector is full of fluid. A small amount of fluid has leaked on to the ground covering a 2 by 3 area. There is a small leak at the inlet to the horizontal separator. Remove the affected soil an make the well capable of preventing the escape of oil and gas. Fix all leaks at the separator. Company was notified via telephone. |
2010206677 | 2014-07-23 | Production Wells | No Violations | My inspection today finds Corps Well Service has replaced all soil that was removed. The company will seed and mulch the location later in the day. |
540569074 | 2016-11-23 0:00 | PW | No Violations | 1.50 |
693127786 | 2014-12-10 0:00 | PW | No Violations | 4.00 |
757862064 | 2020-3-2 0:00:0 | PW | No Violations | 1.00 |
814885216 | 2014-6-2 0:00:0 | PW | No Violations | 2.00 |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
0382540634 | US-OH-124054 | 2014-08-04 | Well operation causing pollution and contamination | |
0540569074 | US-OH-125918 | 2016-12-07 | Well operation causing pollution and contamination | |
0540569074 | US-OH-125919 | 2016-12-07 | Well insufficiently equipped to prevent escape of oil and gas | |
0540569074 | US-OH-125920 | 2016-12-07 | Equipment pressure rated below operating pressure | |
0693127786 | US-OH-127845 | 2014-12-30 | Well operation causing pollution and contamination | |
0814885216 | US-OH-129269 | 2014-07-07 | Well operation causing pollution and contamination | |
1120171587 | US-OH-103046 | 2016-02-19 | Well operation causing pollution and contamination | |
1911014194 | US-OH-119224 | 2016-05-06 | Well operation causing pollution and contamination | |
1911014194 | US-OH-119225 | 2016-05-06 | Well insufficiently equipped to prevent escape of oil and gas |
For data sources see[9]