X

Track changes made to this page

If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.



Privacy policy
Close this window

powered by ChangeDetection

34-121-21317

Well Details

Well ID: 34-121-21317
Loading map...
Country: United States
State: Ohio
County: Noble
Municipality: Noble Township
Operator Name: AVA GAS CORP
Well Pad ID:
Farm/Lease Name: RAYNOR CECIL
License Status: Producing
License Date: 1982-07-13
Spud Date: 1969-04-30
Spud Drilling Contractor: ROSS WELL SERVICE
Final Drill Date: 1969-05-18
Well Total Depth: 5559.00 ft
Configuration: Vertical
Latitude: 39.820000
Longitude: -81.560000

For data sources see[1]

Well History

Well Status Well Status Date Comment
Original Spud 1969-04-30 TRANSFERRED TO AVA GAS CORP. ON 5-23-88.
Completed 1969-05-18 TRANSFERRED TO AVA GAS CORP. ON 5-23-88.
Reached Total Depth 1969-05-18 TRANSFERRED TO AVA GAS CORP. ON 5-23-88.
CO 1982-07-13 2815 AVA GAS CORP GeoDate 7/13/82
Record Last Modified 2017-02-15 TRANSFERRED TO AVA GAS CORP. ON 5-23-88.

For data sources see[2]

Stimulations Data

Stimulation Date Chemical Agent Chemical Agent Concentration (%) Fracking Fluid Volume Mass of Proppant Used (lb) Fracking Company Comments
H2O 0 1500 Bbl 33000

For data sources see[3]

Production Data

Period Operator Name Gas Quantity (mcf) Oil Quantity (bbl) Production Days
1992 AVA GAS CORP 458.00 0.00 70
1994 AVA GAS CORP 0.00 0.00 0
1995 AVA GAS CORP 0.00 0.00 0
1996 AVA GAS CORP 0.00 0.00 0
1997 AVA GAS CORP 0.00 0.00 0
2005 AVA GAS CORP 0.00 0.00 0
2009 AVA GAS CORP 0.00 0.00 365
2010 AVA GAS CORP 0.00 0.00 0
2011 AVA GAS CORP 0.00 0.00 0
2012 AVA GAS CORP 0.00 0.00 0
2013 AVA GAS CORP 0.00 0.00 0

For data sources see[4] [5]

Waste Data

Period Operator Name Waste Type Quantity (bbl) Production Days
1992 AVA GAS CORP Brine 0 70
1994 AVA GAS CORP Brine 0 0
1995 AVA GAS CORP Brine 0 0
1996 AVA GAS CORP Brine 0 0
1997 AVA GAS CORP Brine 0 0
2005 AVA GAS CORP Brine 0 0
2009 AVA GAS CORP Brine 0 365
2010 AVA GAS CORP Brine 0 0
2011 AVA GAS CORP Brine 0
2012 AVA GAS CORP Brine 0 0
2013 AVA GAS CORP Brine 0 0

For data sources see[6] [7]

Inspection Data

Inspections Performed

Inspection ID Inspection Date Inspection Type Inspection Result Inspection Comments
-1109702463 2009-12-1 0:00: PW No Violations
-1552668093 2020-1-2 0:00:0 PW No Violations 0.80
-1580361918 2009-12-1 0:00: PW No Violations
-1971007911 2010-11-8 0:00: PW No Violations
-2125572011 2020-9-22 0:00: PW No Violations 1.00
-334144476 2009-11-19 0:00 PW No Violations
-644811629 2019-2-6 0:00:0 PW No Violations 1.00
-762899968 2015-7-21 0:00: PW No Violations 3.00
0334144476 2009-11-19 Production Wells No Violations Inspection revealed that well is being used for domestic purposes,well is equipped with 8 surface casing and 4.5 production casing and 1.5 tubing and 1-100 bbl tank which is located too close to well it is in violation of tank spacing rule, no I.D.could be found at site 2 photos taken of site.
0342815700 2009-12-10 Production Wells Violations Noted Follow up inspection revealed that owner is still operating well without proper bonding.
0644811629 2019-02-06 Production Wells No Violations The purpose of my inspection was a follow up on a previously issued compliance notice. On the day of my inspection I witnessed the well was equipped with 4.5-inch diameter production casing, 2.375-inch diameter tubing with a 2.375-inch diameter gate valve that was in the closed position. The Casing was tied to a drip with a 1-inch diameter plastic line the drip was connected to a 1-inch diameter steel line and a little joe regulator. It appeared there was domestic gas provided off the well. There was a small leak on the casing head. There was a 100-barrel steel production fluid storage tank, and 500-gallon plastic tank that was no longer connected to the well. There was identification attached to the drip, production was reported as 0 from 1992- 2013, and no production has been reported since that time. Violations are still present, and pictures were taken to assist with the inspection.
0762899968 2015-07-21 Production Wells No Violations My inspection today finds the well is equipped with 4.5 casing and 2.375 tubing. The well appears to be used for domestic gas only. A 100 barrel tank and a 500 gallon plastic tank are the only production equipment on site. The tanks are disconnected from the well.
0780413378 2012-11-07 Production Wells No Violations My inspection today finds that the well appears to be used for domestic gas only. The 100 bbl tank has been moved since the last inspection. There is no identification at the well or on the tank.
0864009017 2014-09-16 Production Wells No Violations My inspection finds the well is being used to for domestic gas only. A one hundred barrel tank is setting on location and not connected to the well. The owner has still not obtained insurance or posted bond with the State.
1109702463 2009-12-01 Production Wells Violations Noted Inspection revealed that well is being used for domestic purposes only,there is a tank spacing violation at site.
1342061064 2010-10-18 Production Wells No Violations Well is being used for domestic purposes only at this time, owner has a Chiefs Order on said well suspending producing operation and post bond and insurance on said well, and tank spacing violation still exist.
1516743755 2018-01-23 Production Wells No Violations The purpose of my inspection was a follow up on a compliance notice numbered -1109702463. During my inspection the well was equipped with 4.5 inch diameter production casing with a tubing head, 2.375 inch diameter tubing, and a tubing valve in the closed position. The 4.5 inch diameter casing had a domestic gas line attached with a little Joe Regulator, a drip, and an open valve. Production equipment was disconnected and consisted of one 100 barrel tank and one 500 gallon poly tank. The production tanks are set less than 50 feet from the well and insurance has not been filed. Violations still exists. Pictures were taken to assist this inspection.
1580361918 2009-12-01 Production Wells No Violations FOLLOW UP TO NOV # -1109702463 Inspection revealed that well is being used for domestic purposes only,there is a tank spacing violation at site.
1706646392 2012-11-07 Production Wells No Violations Inspection revealed that well is being used for domestic purposes only at this time and it was noted that owner has corrected tank spacing violation as noted in previous inspections at well site.

Note: Photos taken at site (2).

1941432854 2017-06-14 Production Wells No Violations The purpose of my inspection was a follow up on a compliance notice numbered -1109702463. The compliance notice sent to Ava Gas Corporation stated violations 1501:9-9-05(A)(2) Violation of tank spacing requirements and 1509.07 Failure to register/obtain or maintain bond/insurance. During my inspection the well was equipped with 4.5 inch diameter production casing with a tubing head and 2.375 inch diameter tubing with a tubing valve in the closed position. The 4.5 inch diameter casing had a domestic gas line attached with a little Joe Regulator, a drip, and an open valve. The well was producing domestic gas only. Production equipment was disconnected and consisted of one 100 barrel tank and one 500 gallon poly tank. The production tanks are set less than 50 feet from the well. Identification was posted at the wellhead. No action has been taken to gain compliance the production tanks remain in violation of 1501:9-9-05(A)(2) Violation of tank spacing requirements and Ava Gas Corporation remains in violation of 1509.07 Failure to register/obtain or maintain bond/insurance. Compliance notice numbered -1109702463 has not been complied with. Pictures were taken to assist this inspection.
1971007911 2010-11-08 Production Wells No Violations Follow Up Inspection to Chiefs Order#2010-41 and inspection revealed that there has been no change in status of well. Owner is still operating wells without proper bonding and insurance.
342815700 2009-12-10 0:00 PW No Violations
780413378 2012-11-7 0:00: PW No Violations 1.00
864009017 2014-9-16 0:00: PW No Violations 1.00
879696475 2019-8-5 0:00:0 PW No Violations 1.00

Violations Commited

Inspection ID Violation ID Violation Date Violation Code Violation Comments
0342815700 US-OH-123587 2009-12-11 Violation of tank spacing requirements
0342815700 US-OH-123588 2009-12-11 Failure to register/obtain or maintain bond/insurance
1109702463 US-OH-102716 2009-12-11 Violation of tank spacing requirements
1109702463 US-OH-102717 2009-12-11 Failure to register/obtain or maintain bond/insurance

For data sources see[8]

References