If you find this page useful and would like to be notified of changes made to this page, start by inputting your email below.
powered by ChangeDetection
Well ID: 34-119-22879 | Loading map...
{"type":"SATELLITE","minzoom":false,"maxzoom":false,"types":["ROADMAP","SATELLITE","HYBRID","TERRAIN"],"mappingservice":"googlemaps3","width":"100%","height":"350px","centre":false,"title":"","label":"","icon":"","visitedicon":"","lines":[],"polygons":[],"circles":[],"rectangles":[],"wmsoverlay":false,"copycoords":false,"static":false,"zoom":14,"layers":[],"controls":["pan","zoom","type","scale","streetview","rotate"],"zoomstyle":"DEFAULT","typestyle":"DEFAULT","autoinfowindows":false,"resizable":false,"kmlrezoom":false,"poi":true,"markercluster":false,"clustergridsize":60,"clustermaxzoom":20,"clusterzoomonclick":true,"clusteraveragecenter":true,"clusterminsize":2,"imageoverlays":[],"kml":[],"gkml":[],"searchmarkers":"","enablefullscreen":false,"scrollwheelzoom":false,"locations":[{"text":"","title":"","link":"","lat":39.8,"lon":-81.74,"icon":""}]} |
Country: United States | |
State: Ohio | |
County: Muskingum | |
Municipality: Meigs Township | |
Operator Name: BIG SKY ENERGY INC | |
Well Pad ID: | |
Farm/Lease Name: CLAPPER WM F | |
License Status: Producing | |
License Date: 1972-09-13 | |
Spud Date: 1972-09-08 | |
Spud Drilling Contractor: | |
Final Drill Date: 1972-12-20 | |
Well Total Depth: 5136.00 ft | |
Configuration: Vertical | |
Latitude: 39.800000 | |
Longitude: -81.740000 |
For data sources see[1]
Well Status | Well Status Date | Comment |
---|---|---|
Original Spud | 1972-09-08 | |
Completed | 1972-12-20 | |
Reached Total Depth | 1972-12-20 | |
CO | 1994-11-28 | 122 TIGER OIL INC |
CO | 1994-11-28 | 2680 ENERGY CONTRACTORS INC GeoDate |
Change of Owner | 1998-09-28 | Operator changed from 2680, ENERGY CONTRACTORS INC to 952, G-R CONTRACTING INC |
Change of Owner | 2013-05-20 | Operator changed from 952, G-R CONTRACTING INC to 1333, BIG SKY ENERGY INC |
Record Last Modified | 2019-06-04 |
For data sources see[2]
Perforation Date | Interval Top (ft) | Interval Base (ft) | Number of Shots |
---|---|---|---|
2006-09-11 | 5000 | 5046 | 2 |
5000 | 5046 | 2 | |
5000 | 5046 | 2 |
For data sources see[3]
Stimulation Date | Chemical Agent | Chemical Agent Concentration (%) | Fracking Fluid Volume | Mass of Proppant Used (lb) | Fracking Company | Comments |
---|---|---|---|---|---|---|
H2O | 0 | 1500 Bbl | 28000 |
For data sources see[4]
Period | Operator Name | Gas Quantity (mcf) | Oil Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | TIGER OIL INC | 2719.00 | 0.00 | 0 |
1985 | TIGER OIL INC | 2876.00 | 0.00 | 365 |
1986 | TIGER OIL INC | 2685.00 | 0.00 | 365 |
1987 | TIGER OIL INC | 2347.00 | 0.00 | 365 |
1990 | TIGER OIL INC | 1364.00 | 0.00 | 365 |
1991 | TIGER OIL INC | 1219.00 | 0.00 | 365 |
1992 | TIGER OIL INC | 680.00 | 0.00 | 365 |
1993 | TIGER OIL INC | 99.00 | 0.00 | 60 |
1994 | TIGER OIL INC | 415.00 | 0.00 | 365 |
1995 | ENERGY CONTRACTORS INC | 290.00 | 0.00 | 365 |
1996 | ENERGY CONTRACTORS INC | 110.00 | 0.00 | 365 |
1997 | ENERGY CONTRACTORS INC | 2701.00 | 0.00 | 365 |
1998 | ENERGY CONTRACTORS INC | 1441.00 | 0.00 | 365 |
2001 | G-R CONTRACTING INC | 0.00 | 0.00 | 365 |
2002 | G-R CONTRACTING INC | 0.00 | 0.00 | 365 |
2003 | G-R CONTRACTING INC | 0.00 | 0.00 | 365 |
2004 | G-R CONTRACTING INC | 3083.00 | 0.00 | 365 |
2005 | G-R CONTRACTING INC | 1213.00 | 0.00 | 365 |
2006 | G-R CONTRACTING INC | 0.00 | 0.00 | 365 |
2007 | G-R CONTRACTING INC | 1132.00 | 0.00 | 365 |
2008 | G-R CONTRACTING INC | 834.00 | 0.00 | 365 |
2009 | G-R CONTRACTING INC | 1248.00 | 0.00 | 365 |
2010 | G-R CONTRACTING INC | 1253.00 | 0.00 | 365 |
2011 | G-R CONTRACTING INC | 714.00 | 0.00 | 365 |
2012 | G-R CONTRACTING INC | 691.00 | 0.00 | 366 |
2013 | BIG SKY ENERGY INC | 0.00 | 0.00 | 365 |
2014 | BIG SKY ENERGY INC | 760.00 | 0.00 | 365 |
2016 | BIG SKY ENERGY INC | 255.00 | 0.00 | 98 |
2017 | BIG SKY ENERGY INC | 0.00 | 0.00 | 0 |
Period | Operator Name | Waste Type | Quantity (bbl) | Production Days |
---|---|---|---|---|
1984 | TIGER OIL INC | Brine | 0 | 0 |
1985 | TIGER OIL INC | Brine | 0 | 365 |
1986 | TIGER OIL INC | Brine | 0 | 365 |
1987 | TIGER OIL INC | Brine | 0 | 365 |
1990 | TIGER OIL INC | Brine | 0 | 365 |
1991 | TIGER OIL INC | Brine | 0 | 365 |
1992 | TIGER OIL INC | Brine | 0 | 365 |
1993 | TIGER OIL INC | Brine | 0 | 60 |
1994 | TIGER OIL INC | Brine | 0 | 365 |
1995 | ENERGY CONTRACTORS INC | Brine | 0 | 365 |
1996 | ENERGY CONTRACTORS INC | Brine | 0 | 365 |
1997 | ENERGY CONTRACTORS INC | Brine | 0 | 365 |
1998 | ENERGY CONTRACTORS INC | Brine | 0 | 365 |
2001 | G-R CONTRACTING INC | Brine | 0 | 365 |
2002 | G-R CONTRACTING INC | Brine | 0 | 365 |
2003 | G-R CONTRACTING INC | Brine | 0 | 365 |
2004 | G-R CONTRACTING INC | Brine | 0 | 365 |
2005 | G-R CONTRACTING INC | Brine | 0 | 365 |
2006 | G-R CONTRACTING INC | Brine | 0 | 365 |
2007 | G-R CONTRACTING INC | Brine | 0 | 365 |
2008 | G-R CONTRACTING INC | Brine | 0 | 365 |
2009 | G-R CONTRACTING INC | Brine | 0 | 365 |
2010 | G-R CONTRACTING INC | Brine | 0 | 365 |
2011 | G-R CONTRACTING INC | Brine | 0 | 365 |
2012 | G-R CONTRACTING INC | Brine | 0 | 366 |
2013 | G-R CONTRACTING INC | Brine | 0 | 365 |
2014 | G-R CONTRACTING INC | Brine | 0 | 0 |
2016 | BIG SKY ENERGY INC | Brine | 0 | 98 |
2017 | BIG SKY ENERGY INC | Brine | 0 | 0 |
Inspection ID | Inspection Date | Inspection Type | Inspection Result | Inspection Comments |
---|---|---|---|---|
-1507612724 | 2014-4-2 0:00:0 | PW | No Violations | 2.00 |
-1948153855 | 2003-10-28 0:00 | PW | No Violations | |
-2013459574 | 2011-11-25 0:00 | PW | No Violations | 1.00 |
-671047231 | 2016-9-20 0:00: | PW | No Violations | 2.00 |
0047086914 | 2017-11-29 | Production Wells | No Violations
-535. On the day of my inspection the well is shut in. The well is equipped with a gas plunger lift set- | |
0096048794 | 2008-04-14 | Production Wells | No Violations | Producing, no problems noted. No tank. |
0329905473 | 2016-04-16 | Production Wells | No Violations | The purpose of my inspection today is a Civil Action Follow-up. I witnessed that the well was equipped with 4.5 inch casing, 2 inch tubing, and a plunger lift system. Valves were closed. Production equipment included a horizontal separator. Identification was located on the separator and well. |
0671047231 | 2016-09-20 | Production Wells | No Violations
--105, I witnessed that the well was equipped with 4.5 inch casing; 2.375 inch tubing and a plunger lift system in heavy vegetation. All valves were in the closed position. Production equipment included a horizontal separator, a motor valve, drip and a 2 inch meter run with a .5 inch orifice and chart recorder with a chart dated 3/2/16 also in heavy vegetation. Identification was present with the last reported production in 2014. | |
1384246627 | 2016-05-03 | Production Wells | No Violations | The follow-up inspection is due to a Temporary Restraining Order issued in the Trumble County Court of Common Pleas and the Chiefs Order #2015-535, Chiefs Order #2016-105.
The well is equipped with a Gas Plunger lift system. The well is shut in at the tubing valve and the tubing annulus. |
1393540725 | 2014-02-27 | Production Wells | Violations Noted
-43, I witnessed that the well was equipped with 4.5 inch casing, 2.375 inch tubing and a plunger lift system. Valves were closed on the casing and open on the tubing. Production equipment included a horizontal separator, a logic controller, drip and a 2 inch meter run with a .5 inch orifice and chart recorder. All valves were open on the sales line. A compressor unit was down stream of the sales meter and was not in operation at the time of inspection. Production records were current and identification was present at the well and the tank battery however the company and phone numbers were incorrect. Company shall legibly identify well. | |
1507612724 | 2014-04-02 | Production Wells | No Violations
-43 & NOV-139540725, I witnessed that the well was equipped with 4.5 inch casing; 2.375 inch tubing and a plunger lift system. Valves were closed on the casing and open on the tubing. Production equipment included a horizontal separator, a logic controller, drip and a 2 inch meter run with a .5 inch orifice and chart recorder. All valves were open on the sales line. A compressor unit was down stream of the sales meter and was not in operation at the time of inspection. Production records were current and identification has been corrected. | |
1948153855 | 2003-10-28 | Production Wells | Violations Noted | |
2013459574 | 2011-11-25 | Production Wells | No Violations | No violations on day of inspections. |
329905473 | 2016-4-16 0:00: | PW | No Violations | 0.50 |
47086914 | 2017-11-29 0:00 | PW | No Violations | 0.70 |
96048794 | 2008-4-14 0:00: | PW | No Violations |
Inspection ID | Violation ID | Violation Date | Violation Code | Violation Comments |
---|---|---|---|---|
1393540725 | US-OH-111637 | 2014-04-23 | Failure to legibly identify well | |
1948153855 | US-OH-119643 | 2003-10-28 | Well shall be plugged |
For data sources see[9]